Weekly Inspection
Chapter 4
Multi-Functional Placer
SM482PLUS Maintenance Handbook
4-5
Checking and Replacing the Head Vacuum Filter
Checking and Replacing the Head Vacuum Filter
Measures
Step 1.
Move the X Frame to front by referring to “Forward
movement of the X-frame” on page 1-3.
Step 2.
Press the 'STOP' and 'RESET' buttons in order after
pressing the 'EMG' button on the OP panel to stop
operation.
For more details, refer to “How to perform emergency stop” on page
1-2.
Step 3.
Check for discoloration of the vacuum filter. (It is
recommended that you inspect for filter discoloration
monthly).
Step 4.
Saparate the coil tube from vacuum filter
Caution
After replacing the Vacuum Filter, check the assembly of the filter
and tube.
(Time required: 30min / No. W-4)

Weekly Inspection
Chapter 4
Multi-Functional Placer
SM482PLUS Maintenance Handbook
4-6
Checking and Replacing the Head Vacuum Filter
Weekly Inspection
Step 5.
Replace the vacuum filter
Step 6.
Release the emergency stop as described in “Releasing
‘Emergency Stop’ mode” on page 1-6 and perform the
operation again.
Caution
Check the vacuum filter every week and replace it within at least 6
months to ensure the vacuum for part pickup is generated properly.
Caution
It is recommended that the solenoid valve, which is a consumable
product, is replaced every two years to ensure stable operation
Dispose of contaminated filters removed from the equipment
immediately as they cannot be reused and improper use may cause
problems with product performance.

Monthly Inspection
Chapter 5
Multi-Functional Placer
SM482PLUS Maintenance Handbook
5-1
Cleaning the Head Spindle
Spindle
Tool for Maintenance
Cleaning liquid, ultra fine fiber cloth, air gun
Measures
Step 1.
Move the X Frame to front by referring to “Forward
movement of the X-frame” on page 1-3.
Step 2.
Press the 'STOP' and 'RESET' buttons in order after
pressing the 'EMG' button on the OP panel to stop
operation.
For more details, refer to “How to perform emergency stop” on page
1-2.
Chapter 5
Monthly Inspection
Step 3.
Remove the tube from the Vacuum Filter
Step 4.
Remove the nozzle
Cleaning the Head Spindle
(Time required: 30min / No. M-1)