SM482PLUS_Maintenance(Eng_Ver2.7).pdf - 第46页
SM482PLUS Maintenance Handbo ok 3-13 Chap ter 3 Daily Inspe ction Multi -Func tional Placer Checking and replacing the Mist Separator Filter Clean the dust from the air to prevent machine failure due to foreign materials…

SM482PLUS Maintenance Handbook
3-12
Chapter 3
Daily Inspection
Multi-Functional Placer
Checking and replacing the Air Filter
Daily Inspection
Step 5.
Separate the container by turning it counterclockwise
Step 6.
Remove and replace the filter from the air filter
container.
Dispose of contaminated filters removed from the equipment
immediately as they cannot be reused and improper use may cause
problems with product performance.
Step 7.
Release the emergency stop as described in “Releasing
‘Emergency Stop’ mode” on page 1-6 and perform the
operation again.

SM482PLUS Maintenance Handbook
3-13
Chapter 3
Daily Inspection
Multi-Functional Placer
Checking and replacing the Mist Separator Filter
Clean the dust from the air to prevent machine failure due to foreign materials when
using pneumatic air.
Measures
Step 1.
Press the 'STOP' and 'RESET' buttons in order after
pressing the 'EMG' button on the OP panel to stop
operation.
For more details, refer to “How to perform emergency stop” on page
1-2.
Step 2.
Shut the main pneumatic pressure supplied to the
machine.
Step 3.
Mist Separator Filter is discolored.
Step 4.
Open the door at the front left bottom of the machine
and lower the lock button of the mist filter container.
Caution
Failure to shut off pneumatic pressure when replacing the air filter
or mist separator filter may result in personal injury. Shut off the
pneumatic line before replacing any of these parts.
Checking and replacing the Mist Separator Filter
(Time required: 30min / No. D-6)

SM482PLUS Maintenance Handbook
3-14
Chapter 3
Daily Inspection
Multi-Functional Placer
Checking and replacing the Mist Separator Filter
Daily Inspection
Step 5.
Separate the container by turning it counterclockwise
Step 6.
Turn the filter clockwise to separate it.
Dispose of contaminated filters removed from the equipment
immediately as they cannot be reused and improper use may cause
problems with product performance.
Step 7.
Release the emergency stop as described in “Releasing
‘Emergency Stop’ mode” on page 1-6 and perform the
operation again.