00193893-04.pdf - 第63页

SIPLACE HF Series Head Reconfiguration Kits 2 Retrofit in structions - SIPLACE HF seri es head reconfiguration kits 05/2006 Edition 63 2.4.3 Configuring the T win Head with SIPLACE Pro : Enter the T winHead in the "…

100%1 / 110
2 Retrofit instructions - SIPLACE HF series head reconfiguration kits SIPLACE HF Series Head Reconfiguration Kits
05/2006 Edition
62
for the FC camera in placement area 1: 2
2
for the IC camera in placement area 1: 2
\ Sensorsystem_Individuum_Nr \ 1020, (locate this record)
\ Auswerte_Nr \
1
\ Kanal-Nummer \
4
\ --- not in use --- \
0
\ ** Korrekturfaktor_A_X ** \
Change 19300 to -19300,
(change sign when positive)
\ ** Korrekturfaktor_B_X ** \ 0
\ ** Korrekturfaktor_C_X ** \
0
\ ** Korrekturfaktor_A_Y ** \
Change -19300 to 19300,
(change sign when negative)
\ ** Korrekturfaktor_B_Y ** \ 0
\ ** Korrekturfaktor_C_Y ** \ 0
\ ** Kamera_Position_X [um] ** \ 646500
\ ** Kamera_Position_Y [um] ** \ 637000
\ ** Kamera_Position_Z [um] ** \ 0
\ ** Kamera_Winkel [1/100 grad] ** \
0
\ XU_Pixel \ 19300
\ YU_Pixel \ 19300
\ Sensorsystem_Individuum_Nr \ 1022, (locate this record)
\ Auswerte_Nr \
1
\ Kanal-Nummer \
2
\ --- not in use --- \
0
\ ** Korrekturfaktor_A_X ** \
Change 79000 to -79000,
(change sign when positive)
\ ** Korrekturfaktor_B_X ** \
0
\ ** Korrekturfaktor_C_X ** \
0
\ ** Korrekturfaktor_A_Y ** \
Change -79000 to 79000,
(change sign when negative)
\ ** Korrekturfaktor_B_Y ** \ 0
\ ** Korrekturfaktor_C_Y ** \ 0
\ ** Kamera_Position_X [um] ** \ 516500
\ ** Kamera_Position_Y [um] ** \ 629500
\ ** Kamera_Position_Z [um] ** \ 5000
\ ** Kamera_Winkel [1/100 grad] ** \
0
\ XU_Pixel \ 79000
\ YU_Pixel \ 79000
SIPLACE HF Series Head Reconfiguration Kits 2 Retrofit instructions - SIPLACE HF series head reconfiguration kits
05/2006 Edition
63
2.4.3 Configuring the TwinHead with SIPLACE Pro
: Enter the TwinHead in the "Set-up Properties" dialog.
2
2
: Reoptimize the set-up in SIPLACE Pro.
2
: Switch the placement machine off at the main switch.
2 Retrofit instructions - SIPLACE HF series head reconfiguration kits SIPLACE HF Series Head Reconfiguration Kits
05/2006 Edition
64
2.4.4 Converting the nozzle changer
2
: Remove the waste tape chute.
2
: Loosen the four screws on the nozzle changer of the C&P head and remove the head.
: Disconnect the cable and the compressed air hose.
2
2
: Use a blanking Y piece to seal off the compressed air hoses to the nozzle changer (or use ca-
ble ties, if necessary).
2
2
2
Cable
Compressed air connector