00193893-04.pdf - 第71页

SIPLACE HF Series Head Reconfiguration Kits 2 Retrofit in structions - SIPLACE HF seri es head reconfiguration kits 05/2006 Edition 71 : Remove the sensor for the C&P hea d reject bin and wire it to the new reject bi…

100%1 / 110
2 Retrofit instructions - SIPLACE HF series head reconfiguration kits SIPLACE HF Series Head Reconfiguration Kits
05/2006 Edition
70
: Pull the two (or four if you are installing the FC camera) connecting cables for the IC camera
out of the machine frame and connect them to the IC camera:
IC camera: 03003449-01 (X5), 03003438-01 W2 (X37)
2
: The FC camera can be fitted and connected up in the same way.
FC camera: 03003450-01, 03003438-01 W1
2
: Insert the fixings for the reject bin for the P&P / TwinHead and screw in place.
2
2
2
2
2
2
Cables for FC camera
Cables for IC camera
SIPLACE HF Series Head Reconfiguration Kits 2 Retrofit instructions - SIPLACE HF series head reconfiguration kits
05/2006 Edition
71
: Remove the sensor for the C&P head reject bin and wire it to the new reject bin for the P&P or
TwinHead.
: Attach the sensor to the mount for the new reject bin.
2
: Insert the new reject bin.
2
: Insert the new nozzle changer (P&P / TwinHead) and fix in place with four screws.
2
Remove the sensor
Refit the sensor
2 Retrofit instructions - SIPLACE HF series head reconfiguration kits SIPLACE HF Series Head Reconfiguration Kits
05/2006 Edition
72
2.4.6 Replacing the placement head
2
Wear an ESD armband for the whole time you are working on the placement head and servos. 2
2
2
The conversion is easiest to carry out from locations 2 and 4. 2
2
2
: Detach these two hoses:
2
2
: Remove the top and bottom hoses.
2
2