00193893-04.pdf - 第95页

SIPLACE HF Series Head Reconfiguration Kits 2 Retrofit in structions - SIPLACE HF seri es head reconfiguration kits 05/2006 Edition 95 : Loosen the four screws on each T winHead module and remove both modules. 2 2 : Loos…

100%1 / 110
2 Retrofit instructions - SIPLACE HF series head reconfiguration kits SIPLACE HF Series Head Reconfiguration Kits
05/2006 Edition
94
: Open the strain relief clip (pushbutton).
2
2
: Unscrew the entire strain relief.
2
: Detach the four ribbon cables from the TwinHead (photograph below).
2
2
2
2
2
2
2
2
Plug
SIPLACE HF Series Head Reconfiguration Kits 2 Retrofit instructions - SIPLACE HF series head reconfiguration kits
05/2006 Edition
95
: Loosen the four screws on each TwinHead module and remove both modules.
2
2
: Loosen the four screws on the board and remove the board.
Be careful not to lose the washers!
2
2
2
2
Screws
2 Retrofit instructions - SIPLACE HF series head reconfiguration kits SIPLACE HF Series Head Reconfiguration Kits
05/2006 Edition
96
: Place the DLM head template on the head fixing plate.
Remove any excess screws and add any necessary screws:
Fixing screws: 4x DIN 912 - M4 x 18-8.8, item no.: 00095023-01xx,
Sealing screws: 9x DIN 913 - M4 x 6-ST, item no.: 00309422-01-xx.
Screws in the wrong place could affect the flow of cooling air to the X-axis motor.
2
2
2
Always use the standard tool.
Make sure that the screws are of the right length. The lengths are different for C&P heads and the
TwinHead.
If you use the wrong screws, there is a risk of damaging the thread on the head plate.
Tightening torque for the fixing screws: 2.7 Nm. 2
. 2
Seal for
head plate
Fixing
C&P 6/12