SIPLACE HF Series Head Reconfiguration Kits 2 Retrofit in structions - SIPLACE HF seri es head reconfiguration kits 05/2006 Edition 89 : Remove the body of the IC camera . : Attach the Risk of head crash warning label to…

100%1 / 110
2 Retrofit instructions - SIPLACE HF series head reconfiguration kits SIPLACE HF Series Head Reconfiguration Kits
05/2006 Edition
88
2.5.3 Converting the nozzle changer / removing the cameras
2
: Remove the waste tape chute.
2
: Loosen the four M4 screws on the nozzle changer of each TwinHead and remove the head.
2
2
: Remove the large reject bin for the TwinHead.
: Loosen the two screws (M5) on the TwinHead reject bin mount and pull the bin out.
2
2
SIPLACE HF Series Head Reconfiguration Kits 2 Retrofit instructions - SIPLACE HF series head reconfiguration kits
05/2006 Edition
89
: Remove the body of the IC camera.
: Attach the Risk of head crash warning label to the body of the IC camera (if it is not already
attached).
2
2
: Remove the supporting frame for the IC camera from the base plate by folding it up, and then
pulling it up and out.
2
2
2 Retrofit instructions - SIPLACE HF series head reconfiguration kits SIPLACE HF Series Head Reconfiguration Kits
05/2006 Edition
90
: Remove the fiducial plate, if present.
2
The fiducial plate is very heavy. 2
2
: Detach the IC camera cable from the connections on the base plate.
: Push the cables into the machine frame to protect them against damage.
: Loosen the four screws (M6) on the IC camera base plate and remove.
2
: The FC camera can be dismantled in the same way, if necessary.
: Carefully fit the nozzle changer extension.
Be careful, the extension is very fragile.
2
4 screws