Specification SIPLACE X-Series规格说明书2.pdf - 第63页

63 Technical Data Transport and Delivery Configuration Description Within Europe, the machine is delivered on a robust wooden pallet. If sent over- seas, the machine is pa ck- aged in a wooden crate. Configuration when d…

100%1 / 80
62
Technical Data
Spacing Distances for the Placement Machine
With MTC
63
Technical Data
Transport and Delivery Configuration
Description
Within Europe, the machine
is delivered on a robust
wooden pallet. If sent over-
seas, the machine is pack-
aged in a wooden crate.
Configuration when
delivered
The extension kit on the
PCB input side with the
computer unit or the box
PC are disconnected from
the basic machine.
All electrical cables
to the basic machine are
disconnected.
The lane on the single con-
veyor is set to a width of
210 mm. On the dual con-
veyor, the default width of
lane 1 is 100mm and of
lane 2 is 210 mm.
The input conveyors of the
single and dual conveyor
are dismantled. The elec-
trical cables to the convey-
or motors and light
barriers are disconnected.
Both keyboards and the
monitors are disconnect-
ed.
The main fault indicator is
dismantled.
Transport dimensions and weight
Means of transport
A fork-lift truck with the following specification will be needed
to carry the machine in its crate:
Length
Width
Height
2404 mm
2790 mm
1600 mm
Weight
X4I
X4
X3
X2
Dispatch Dispatch
within Europe overseas
3859 kg 4359 kg
4004 kg 4504 kg
3980 kg 4420 kg
3836 kg 4336 kg
Fork length
Lifting power
Clear fork width
min. 1800 mm
min. 6000 kg
min. 350 mm
Engagement point
for the fork-lift
Engagement point
for the fork-lift
64
Standard List
The following functions are contained as standard in the SIPLACE X-series without any extra
charge:
Standard features X4I X4 X3 X2
Vacuum sensor X X X X
Force measurement X X X X
Force sensor n.a.
a
a) Not applicable.
XXX
Fiducial & ink spot detection X X X X
Nozzle changer for the TwinStar n.a. X X X
Set of TwinStar nozzles n.a. X X X
Set of standard nozzles per head X X X X
Service box X X X X
Single conveyor, stationary side right X X X X
Single conveyor, stationary side left X X X X
Wide board configuration X X X X
PCB buffer function on conveyor X X X X
PCB stopper laser light barrier X X X X
Automatic electrical PCB width adjustment X X X X
Operation on both sides X X X X
LCD monitors X X X X
Touch-screen monitor X X X X
indicator lamps X X X X
Tape cutter with reject bin X X X X
Tape separating plates X X X X
01005 placement X X X X
Magnetic pin support X X X X