00194086-01.pdf - 第102页

4 Setting up t he placement system Us er Manual SIPLACE CS 4.2 Setting up the placement system Software Version SR. 408.xx03/2006 US Edition 102 4.2 Setting up the placement system 4.2.1 Safety inst ructions W ARNING – T…

100%1 / 160
User Manual SIPLACE CS 4 Setting up the placement system
Software Version SR.408.xx 03/2006 US Edition 4.1 Transport configuration and infrastructure
101
4.1.4 Compressed air supply
4.1.4.1 Technical data
The technical data for the compressed air supply can be found in sections 3.3.2 and 3.3.3, page
66
.
4
4.1.4.2 Checking the compressed air supply
Check that the compressed air supply conforms to the prescribed machine specifications.
PLEASE NOTE:
The document entitled "Network configuration (electrical and compressed air) for SMD systems
on the customer's premises", item no. 00191409-xx, describes the action that can be taken to
meet the required specifications.
Æ Record the compressed air characteristics at the installation location.
4.1.5 Main power supply
4.1.5.1 Electrical ratings
The electrical ratings can be found in section 3.3.1, page 66.
4
4.1.5.2 Checking the main power supply
Check that the main power supply conforms to the prescribed machine specifications.
PLEASE NOTE:
The document entitled "Network configuration (electrical and compressed air) for SMD systems
on the customer's premises", item no. 00191409-xx, describes the action that can be taken to
meet the required specifications.
4 Setting up the placement system User Manual SIPLACE CS
4.2 Setting up the placement system Software Version SR.408.xx03/2006 US Edition
102
4.2 Setting up the placement system
4.2.1 Safety instructions
WARNING
The applicable accident prevention regulations concerning the transportation of heavy goods
must be followed.
There is a risk that the machine will tip over if you do not use the pallet jack specified in section
4.1.3
to transport the placement machine.
In particular, you should wear safety boots to minimize the risk of crushing your feet.
Attach the pallet jack only at the points identified by A in Fig. 4.1 - 1).
4.2.2 Setting up the placement machine
Æ Raise the placement system using the fork-lift truck and adjust the feet until there is a gap of
830 mm between the top edge of the PCB conveyors and the bottom edge of the feet.
Æ Leave a gap of 1 to 3 mm between the PCB conveyors of the placement system.
Æ Align all the placement systems exactly in line with one another. Use a cord pulled tight to en-
sure this.
Æ Adjust each placement system using a spirit level with an accuracy of 0.02 mm/m.
Æ Lock the feet in position.
Æ Check the placement system again using the spirit level and correct the settings, if necessary.
CAUTION
Make sure that you remove all the shipping braces from the placement system. 4
Æ Fit any components that were dismantled for dispatch.
Æ Connect all the electrical and pneumatic lines.
RISK OF DEATH
The electrical connection work MUST be carried out only by appropriately trained and certi-
fied personnel. 4
User Manual SIPLACE CS 4 Setting up the placement system
Software Version SR.408.xx 03/2006 US Edition 4.3 Adjusting the component trolley to another PCB transport height
103
4.3 Adjusting the component trolley to another PCB
transport height
4.3.1 Tools
Allen keys, set up to 8 mm
4.3.2 Safety instructions
WARNING DANGER OF CRUSHING
Remove all the feeders from the component table bed before you adjust the table height of the
component trolley. Act with considerable care during the conversion process because the table
bed is very heavy. 4
4
Fig. 4.3 - 1 Adjusting the component trolley to another PCB transport height
(1) Clamping screws, 4 per side
(2) Holes in the cross-beam for adjusting the table height to 830, 900, 930 and 950 mm