00194086-01.pdf - 第82页
3 Technical data User Manual SIPLACE CS 3.8 6-segment Collect&Place head Software Version SR.408.xx03/2006 US Edition 82 3 Fig. 3.8 - 2 Structure of the 6-segment Collect&Place head with standard component vision…

User Manual SIPLACE CS 3 Technical data
Software Version SR.408.xx 03/2006 US Edition 3.8 6-segment Collect&Place head
81
3.8 6-segment Collect&Place head
3.8.1 Structure of the 6-segment Collect&Place head with standard component
vision camera
3
Fig. 3.8 - 1 Structure of the 6-segment Collect&Place head with standard component vision camera - part 1
(1) Star with 6 sleeves (2) Motor for "Reject" valve adjustment drive
(3) Component vision camera (4) Z-axis drive
(5) Star motor

3 Technical data User Manual SIPLACE CS
3.8 6-segment Collect&Place head Software Version SR.408.xx03/2006 US Edition
82
3
Fig. 3.8 - 2 Structure of the 6-segment Collect&Place head with standard component vision camera - part 2
3
(1) Forced air valve
(2) Turning station
(3) Vacuum generator

User Manual SIPLACE CS 3 Technical data
Software Version SR.408.xx 03/2006 US Edition 3.8 6-segment Collect&Place head
83
3.8.1.1 Description
– The 6-segment Collect&Place head works using the "collect & place" principle, i.e. the compo-
nents are held by the nozzles with the aid of a vacuum and, after one complete pick-up cycle,
are placed gently and accurately on the PCB with the aid of forced air. The vacuum in the noz-
zles is also checked several times to determine whether the components were picked up and
set down correctly.
– The "adaptive" sensor stop mode of the z axis compensates for any irregularity of the PCB sur-
face when the components are set down.
– All the components are inserted with the same cycle time. Before the component is inserted, it
is measured by the optoelectronic vision module.
– The component vision camera creates an image of the current component.
– The precise position of the component is also determined.
– The package form of the current component is compared against the programmed package
form in order to identify it. Any components that cannot be identified are rejected.
– The turning station turns the component to the required placement position.
– Defective components are rejected and are picked up again during a repair run.
3.8.1.2 Technical data
3
Component range 0201 to PLCC44, including BGA, µBGA, flip-chip,
TSOP, QFP, PLCC, SO to SO32, DRAM
Component specification
max. height
min. lead pitch
min. bump pitch
min. ball/bump diameter
min. dimensions
max. dimensions
max. weight
6 mm (10.7 mm available upon request)
0.5 mm
0.35 mm
0.2 mm
0.6 mm x 0.3 mm
18.7 mm x 18.7 mm
2 g
Programmable set-down force 2.4 to 5.0 N
Max. placement rate 10,000 comp/h
Nozzle types 9 xx
Angular accuracy ± 0.5° / 3 σ ± 0.7° / 4 σ
Placement accuracy ± 68µm / 3 σ ± 90µm / 4 σ