00194086-01.pdf - 第82页

3 Technical data User Manual SIPLACE CS 3.8 6-segment Collect&Place head Software Version SR.408.xx03/2006 US Edition 82 3 Fig. 3.8 - 2 Structure of the 6-segment Collect&Place head with standard component vision…

100%1 / 160
User Manual SIPLACE CS 3 Technical data
Software Version SR.408.xx 03/2006 US Edition 3.8 6-segment Collect&Place head
81
3.8 6-segment Collect&Place head
3.8.1 Structure of the 6-segment Collect&Place head with standard component
vision camera
3
Fig. 3.8 - 1 Structure of the 6-segment Collect&Place head with standard component vision camera - part 1
(1) Star with 6 sleeves (2) Motor for "Reject" valve adjustment drive
(3) Component vision camera (4) Z-axis drive
(5) Star motor
3 Technical data User Manual SIPLACE CS
3.8 6-segment Collect&Place head Software Version SR.408.xx03/2006 US Edition
82
3
Fig. 3.8 - 2 Structure of the 6-segment Collect&Place head with standard component vision camera - part 2
3
(1) Forced air valve
(2) Turning station
(3) Vacuum generator
User Manual SIPLACE CS 3 Technical data
Software Version SR.408.xx 03/2006 US Edition 3.8 6-segment Collect&Place head
83
3.8.1.1 Description
The 6-segment Collect&Place head works using the "collect & place" principle, i.e. the compo-
nents are held by the nozzles with the aid of a vacuum and, after one complete pick-up cycle,
are placed gently and accurately on the PCB with the aid of forced air. The vacuum in the noz-
zles is also checked several times to determine whether the components were picked up and
set down correctly.
The "adaptive" sensor stop mode of the z axis compensates for any irregularity of the PCB sur-
face when the components are set down.
All the components are inserted with the same cycle time. Before the component is inserted, it
is measured by the optoelectronic vision module.
The component vision camera creates an image of the current component.
The precise position of the component is also determined.
The package form of the current component is compared against the programmed package
form in order to identify it. Any components that cannot be identified are rejected.
The turning station turns the component to the required placement position.
Defective components are rejected and are picked up again during a repair run.
3.8.1.2 Technical data
3
Component range 0201 to PLCC44, including BGA, µBGA, flip-chip,
TSOP, QFP, PLCC, SO to SO32, DRAM
Component specification
max. height
min. lead pitch
min. bump pitch
min. ball/bump diameter
min. dimensions
max. dimensions
max. weight
6 mm (10.7 mm available upon request)
0.5 mm
0.35 mm
0.2 mm
0.6 mm x 0.3 mm
18.7 mm x 18.7 mm
2 g
Programmable set-down force 2.4 to 5.0 N
Max. placement rate 10,000 comp/h
Nozzle types 9 xx
Angular accuracy ± 0.5° / 3 σ ± 0.7° / 4 σ
Placement accuracy ± 68µm / 3 σ ± 90µm / 4 σ