User Manual SIPLAC E CS 5 Tasks on the machine Software Vers ion SR.408.xx 03/2006 U S Edition 5.9 Operating s tatus indicator lamp 127 Error d isplay on off unchanged M achine e rror, right on off unchanged Tr ack empt …

5 Tasks on the machine User Manual SIPLACE CS
5.9 Operating status indicator lamp Software Version SR.408.xx03/2006 US Edition
126
5.9.3 Programmed operating status displays
The following table shows the programmed operating status displays in the standard configuration
(version as supplied) and lists their meaning on the individual lamps of the main fault indicator.
The entries in the table next to "flashes" refer to the frequency with which the relevant lamp flashes
for a given event. The entry (1, 5), for example, can be explained as follows:
– The first number in the brackets indicates the time, expressed in 100 ms intervals, for which
the fault indicator lamp is switched on, i.e. 1 x 100 ms in the above example.
– The second number in the brackets indicates the time, expressed in 100 ms intervals, for
which the fault indicator lamp is switched off, i.e. 5 x 100 ms in the above example.
5
L1 (white)
(right lamp)
L2 (green) L3 (white)
(left lamp)
Meaning
Status display
flashes (1, 10) flashes (7, 7) flashes (1, 10) Reference run
unchanged flashes (1, 5) unchanged Waiting until axes in position
unchanged flashes (7, 7) unchanged Waiting for setup data
unchanged flashes (7, 7) unchanged Waiting for cluster data
unchanged flashes (7, 7) unchanged Load table program
unchanged flashes (7, 7) unchanged Position detection
unchanged flashes (1, 10) unchanged Bad fiducial detection
unchanged flashes (7, 7) unchanged Nozzle configuration test
unchanged flashes (7, 7) unchanged Feeder position detection
unchanged flashes (7, 7) unchanged One track is empty
unchanged flashes (7, 7) unchanged No further track available
unchanged flashes (7, 7) unchanged Go to refill position
unchanged flashes (7, 7) unchanged Transport being initialized
unchanged flashes (7, 7) unchanged Place PCB in input conveyor
flashes (1, 10) flashes (7, 7) unchanged Remove PCB from output conveyor
unchanged flashes (7, 7) flashes (1, 10) Remove PCB from output conveyor 2
flashes (1, 10) flashes (7, 7) flashes (1, 10) Width adjustment
unchanged flashes (1, 10) unchanged Transport PCB
flashes (1, 10) flashes (7, 7) flashes (1, 10) Both output conveyors are cleared
on flashes (1, 10) on Transport error
on off on Go to service position
on Placement
flashes (1, 20) Waiting for processing data

User Manual SIPLACE CS 5 Tasks on the machine
Software Version SR.408.xx 03/2006 US Edition 5.9 Operating status indicator lamp
127
Error display
on off unchanged Machine error, right
on off unchanged Track empty, right
on off unchanged Nozzle configuration, right
on off unchanged Transport error, right
on off on Fiducial error, left and right
on off on Fiducial error, left and right
unchanged off on Track empty, left
unchanged off on Nozzle configuration, left
unchanged off on Transport error, left
unchanged off on Machine error, left
Pick-up error display
unchanged unchanged flashes (1, 20)
First track empty, left
unchanged unchanged flashes (5, 20)
Further tracks empty, left
unchanged unchanged flashes (5, 5)
Penultimate track in use
unchanged unchanged flashes (1, 2)
Last track in use, right
flashes (1, 20) unchanged unchanged
First track empty, right
flashes (5, 20) unchanged unchanged
Further tracks empty, right
flashes (5, 5) unchanged unchanged
Penultimate track in use, right
flashes (1, 2) unchanged unchanged
Last track in use, right
L1 (white)
(right lamp)
L2 (green) L3 (white)
(left lamp)
Meaning
5 Tasks on the machine User Manual SIPLACE CS
5.9 Operating status indicator lamp Software Version SR.408.xx03/2006 US Edition
128