7OM-1603-006_w.pdf - 第88页

7OM-1603 Chapter 2 : 2. Menus for Automatic Operation 2-19 1 109-001 (F02_01) Fdr No. Shown are the feeder Nos. in the placement feeder location data. When the multi-layer tray feeder is connected, the feeder Nos. (Fdr N…

100%1 / 195
7OM-1603
2-18
Chapter 2 : 2. Menus for Automatic Operation
(F02) Tray Feeder Data
"Tray" Edit window F7B14
Graphic
Development
1109-003
7OM-1603
Chapter 2 : 2. Menus for Automatic Operation
2-19
1109-001
(F02_01) Fdr No.
Shown are the feeder Nos. in the placement feeder location data.
When the multi-layer tray feeder is connected, the feeder Nos. (Fdr Nos.)
become as follows.
Multi-Layer Tray Feeder #1
: 501 to 599
Multi-Layer Tray Feeder #2
: 601 to 699
501 to 599
601 to 699
Multi-Layer Tray Feeder #1
Rear Side of Machine
Front Side of Machine
Multi-Layer Tray Feeder #2
Multi-Layer Tray Feeder #1, #2 F7B15
(F02_02) Component No.
Shown are the component Nos., in this section.
(F02_03) Component ID
Set component IDs in the text boxes.
7OM-1603
2-20
Chapter 2 : 2. Menus for Automatic Operation
(F02_04) C
Set control commands in the text boxes.
Notice
If a control command other than the following ones is used, the step
becomes invalid.
- (hyphen)
: This command handles the steps as those for the placement
feeder location data.
E
: This command shows the end of the placement feeder location
data.
The step where "E" is set is valid.
S
: This command invalidates the steps specied as placement
feeder location data.
X
: This command invalidates the steps specied as placement
feeder location data and shows the end of the data.
(F02_05) Comment
Set a comment for each Fdr No.Up to 32 characters (alphanumerics and
symbols) can be used. Alphanumeric characters and symbols can be used.
Note
(a) The performance of the machine is not affected by these commands.
In other words, it has nothing to do with or without these comments.
(b) It is recommended to set helpful information on components related
to the feeder Nos. (Fdr No.)
(F02_06) Component Library Comment
Displayed are the comments entered in the component library data.
(F02_07) Carrier Type
Displayed is the data specied in the component library data.
(F02_08) Used Parts
Displayed is the number of components to be used for one unit PCB.
(F02_09) Nozzle Type
Shown is the number of components to be used for one unit PCB.