00196770-04_VD_SSW_705_04_SP2_DE_EN.pdf - 第25页

Station Software 705.04 SP2 / Version De scription Ausgabe 06/2012 Edition D1-69191553 Machine stopped du ring placem ent with an exception and needed a rebo ot (when placing high components out of MTC). D1-69279620 D1-7…

100%1 / 62
Station Software 705.04 SP2 / Version Description Ausgabe 06/2012 Edition
8 Corrected errors
The 705.04 SP2 station software version contains all the error corrections of the previous versions
701.01 – 705.04 SP1. Additionally, the following errors have been corrected in this version:
Error no. Error description
D1-62055103 Incorrect control of the lamp indicators.
D1-66221447 The zero point corrections could not be transferred to the software by the
intermediate distributor.
D1-66510192 An error was displayed on an 2x8 mm feeder (red LED). In spite of this, the
machine picked up from this feeder.
D1-67655607
D1-69213143
D1-70140490
Error message "Cover foil broken: component:" was still displayed after the
error had been fixed.
D1-67778301
D16058-4811
D16120-2861
Problems while measuring the component via the stationary camera. In order
to avoid scattered light, the component sensor of the CPP head will therefore
be switched off before the component centering with the stationary camera or
the coplanarity measurement take place.
D1-68389204 Field test 705.04.SP1: Software hung up during production.
D1-68686001
D16275-119525
Possibility of placing wrong components in partial setups.
D1-68715501 The machine reported a fatal error after a pickup error.
D1-68759501 Component broke during dipping process.
D1-68778701 Sporadically, a hardware warning was displayed after reboot.
D1-68824501
D1-69455601
D1-69693501
D1-70795701
D1-70822701
D1-70844901
D1-71124601
D1-71551914
Hardware warning not significant.
D1-68887201
D1-69192130
Pickup problems with selected segments. After a reference run it was ok.
D1-69038301 The station software hung up after the operator tried to reactivate an
automatically deactivated segment on a C&P20 head.
D1-69038350 A software protection fault occurred on an X4I placement machine.
D1-69038398 Protocol violation when HCU controlled the C&P20 DP axes (embedded SW +
station software).
D1-69151101 SX placement machines: HCU does not answer and communication is
interrupted; after a short period of time it is reactivated (embedded SW).
D1-69183313
D16334-2955
Unhandled exception on an SX2 placement machine. This happened when
referencing the star axis manually failed.
D1-69183365 Feeder warnings were displayed on the screen although everything was
working well.
24
Station Software 705.04 SP2 / Version Description Ausgabe 06/2012 Edition
D1-69191553 Machine stopped during placement with an exception and needed a reboot
(when placing high components out of MTC).
D1-69279620
D1-70795738
An orange icon for feeder mismatch was displayed on the GUI but no
difference was visible.
D1-69413619
D16159-2426
It was possible to adjust the feeder pitch on the Operator activity level.
D1-69439913
D1-68775501
D16159-2426
A CPP placement head touched the placed board on an X4 placement
machine.
D1-69803411 Problem with Language Pack. Characters were not readable after switching
from English to Polish.
D1-70436501 On an SX4 placement machine an axis warning was displayed after the
reference run during booting.
D1-70445512 The pressure control valve blew a 0201 component out of the component
pocket.
D1-70811301 "Reading barcode" in the "Manual Operations" did not work for PCB Barcode
with PCB camera.
D1-71020801 A 01005 component was incorrectly placed because of faulty tolerance class.
D1-71187163
D1-60414201
D1-68210501
D1-70474001
D1-71103401
A CPP placement head placed a 0201 component with high force. Thereafter,
the component stuck in the nozzle.
D1-71621601 Incoming SMEMA signals were not evaluated on the GUI.
D1-71692897 The required function (changing fixed conveyor rail) was not performed, if the
machine was in production mode before and the operator then clicked on
"Stop production - Restart" in the latest function.
D1-72081601 The station software hung up after a software update.
D1-72982411 When a component shape was taught in the component shape wizard after
having upgraded the station software, the tolerance fell to 1% of the overall
size.
D1-73008901 As a second gantry was re-railed on an SX2 placement machine and the GCU
was not plugged, the machine was operated as an SX1. If gantry 1 then was
moved to the service position it could possibly touch gantry 2.
D1-73492701 Teaching of placement position and placing with high force did not work
together.
D1-73635751 The machine started with an unspecified hardware error for the conveyor E/A
module.
D1-73966879 The machine reported communication failure between two Y-axes.
D1-74037741 After components were taught in Chinese language, the station software hung
up during the robustness analysis.
D1-75321705 Error messages 30507 (hardware warning) and 30576 (unspecified hardware
error) were displayed when the machine was started.
D16006-11801 On an SX-series placement machine the tables could not be removed for a
setup change.
D16120-4012 An SX4 placement machine with hung up during vacuum tooling.
D16198-8327 Bad quality of a placed board (missing components and spattering).
25
Station Software 705.04 SP2 / Version Description Ausgabe 06/2012 Edition
D16223-6011
D1-73633618
Unspecified hardware error on an X4I placement machine.
D16247-4808 An X4I placement machine hung up during the component check by Vision.
D16422-8207 Sporadically, an SX-series placement machine hung up and had to be
rebooted.
Table 8-1: Corrected errors
26