SOM-1613-002.pdf - 第17页
16 Tg0780-PM-SO 0312-002 9. Device Offset 9. Device Offset It is necessary to change data in the following cases. • Positioning width is too narrow . • Positioning width is too wide. • The of fset data is cleared for an …

15 Tg0780-PM-SO0209-001
8. Maintenance
8. Maintenance
8.1 Maintenance Spots
8.2 Inspection
Table 3
8.3 Lubrication
Lubrication Spots
Linear Guide Rail
Ball Screw
(Chute and Conveyor Widths)
Lubrication
Frequency
6 months
6 months
Inspection Item
Linear Guide Rail
Ball Screw
Inspection
Frequency
6 months
6 months
Checking and Countermeasures
• Wipe off dirt and dust with a rag.
• Wipe off dirt and dust with a rag.
Grease or Oil
• DAPHNE EPONEX GREASE No. 1
• DAPHNE EPONEX GREASE No. 1
Table 4
Fig. 7
Fibers of a cloth might cause machine breakdown, if
left on the machine after cleaning using a cloth. Use a
type of cloth leaving fibers as less as possible.
CAUTION
Ball Screw
Linear Guide
(Front Side of Machine)

16 Tg0780-PM-SO0312-002
9. Device Offset
9. Device Offset
It is necessary to change data in the following cases.
• Positioning width is too narrow.
• Positioning width is too wide.
• The offset data is cleared for an unaccountable reason.
When the [Device Offset] tab is pressed at the ''Device Offset'' tab
sheet, the following tab sheet appears on the screen.
P.C.B. locate lever [mm]
This is the offset data used to correct the positional deviation of the
P.C.B. locate lever (P.C.B. locate pin) in the P.C.B. transfer direction.
A plus value shifts the positioning of P.C.B. locate lever (P.C.B.
locate pin) to the maximum P.C.B. size direction.
Data is factory-set at shipment. Do not change
data unless necessary.
CAUTION
Fig. 9
Fig. 8
*1
P.C.B.
(-)
(+)
P.C.B. Locate Leve
r

Tg0780-PM-SO
RH BLOCK
(Control Box Section)
RG BLOCK
(Relay Sequence Panel)
RA BLOCK
(Primary Power
Supply Section)
Control Box for
Oil Cooler
UA53(P.C.B.)
(I/F)
UA54(P.C.B.)(F12)
UA54(P.C.B.)(F34)
RH BLOCK
(Power Unit in
Control Section)
RL BLOCK
(Power Unit)
Vacuum Pump Motor
Service Power Outlet
Dust Box
RC BLOCK
(Panel 1)
RF BLOCK
(Panel 4)
RF BLOCK
(Panel 3)
10. Material
10.1 Parts Location
Layout of Main Machine Section 1 for TCM-X100
10. Material
0312-002-(M765YRL--A0001) 17
The -marked area is specially specified.
Note