SOM-1653-001.pdf - 第17页
Tg0756-PM-SO 0206-001 16 5.1 Pattern Program (5) B-X [mm], B-Y [mm] When "Optional" is set in the "Unit P .C.B. B.B.R." text box, it is re- quired to set the coordinates of each bad mark based on the …

Tg0756-PM-SO
Location of Bad Mark (BX
1
, BY
1
)
Placement Coordinate Reference Point
(OX
1
, OY
1
)(OX
2
, OY
2
)Pattern Origin (OX
3
, OY
3
)
Location of Bad Mark (BX
1
, BY
1
)
(OX
1
, OY
1
) (OX
2
, OY
2
) Pattern Origin (OX
3
, OY
3
)
Placement Coordinate Reference Point
(3) X, Y for P-No. 1 Step
Set the coordinates (BX
1, BY1) for the bad mark position.
Unit: mm
Fig. 15
X [mm]
Y [mm]
010.00
010.00
TIM-X100R
Fig. 16
TIM-X100F
(4) C for P-No. 1 Step
Set the control command to "B".
Do not set a B command for other than P-No. 1.
Fig. 17
CB
0206-001 15
5.1 Pattern Program
Note

Tg0756-PM-SO0206-001 16
5.1 Pattern Program
(5) B-X [mm], B-Y [mm]
When "Optional" is set in the "Unit P.C.B. B.B.R." text box, it is re-
quired to set the coordinates of each bad mark based on the place-
ment coordinate reference No
.
Unit: mm
Placement Coordinate
Reference (No)
Bad Mark of Pattern 1
Bad Mark of Pattern 2
Bad Mark of Pattern 3
Bad Mark of Pattern 4
Pattern 4
(B-X
4
, B-Y
4
)
Pattern 3
(B-X
3
, B-Y
3
)
Pattern 2
(B-X
2
, B-Y
2
)
Pattern 1
(B-X
1
, B-Y
1
)
TIM-X100F
Placement Coordinate
Reference (No)
Bad Mark of Pattern 1
Bad Mark of Pattern 2
Bad Mark of Pattern 3
Bad Mark of Pattern 4
Pattern 4
(B-X
4
, B-Y
4
)
Pattern 3
(B-X
3
, B-Y
3
)
Pattern 2
(B-X
2
, B-Y
2
)
Pattern 1
(B-X
1
, B-Y
1
)
TIM-X100R
Fig. 18
B-X [mm]
B-Y [mm]
000.00
000.00
Fig. 19
Do not set any coordinates in the text boxes of the last line (last
step No.).
Keep them as "000.00".
Note

Tg0756-PM-SO0206-001 17
5.2 Example of Pattern Program Creation
5.2 Example of Pattern Program Creation
Repetitive Patterns (Unit P.C.B. B.B.R. Function Enabled)
Described below are the typical examples of data creation.
The preparation example is described as based on TIM-X100R.
For TIM-X100F, the P.C.B. reference is located on the front
right.
(1) Information on Pattern Program Creation
• P.C.B. Size and Packaged Posture & IDs of Components
Set the same parameters as in "Volume 3: Programming and Ma-
chine Data, Section 2, 3.1 Single Pattern" in the instruction manual
for the main machine.
• Placement Coordinates and Angles (Z=Theta)
Note
Fig. 20 General View
Fig. 21 Pattern 1 (Magnified View)
Placement Coordinate Reference Point
Location of Bad Mark (BX1, BY1)
(OX1, OY1) (OX2, OY2) Pattern Origin (OX3, OY3)
Pattern 1 Pattern 2 Pattern 3
Placement Coordinate
Reference Point
X
3
Y
3
X
2
Y
2
X
1
Y
1
OY
1
OX
1