SOM-1653-001.pdf - 第21页

Tg0756-PM-SO 0206-001 20 5.3 "Pattern Program" Edit Window 5.3 "Pattern Program" Edit Window 5.3.1 "P .C.B. Data" T ab • Sheet Layout When the "P .C.B. Data" tab is pressed in the …

100%1 / 33
Tg0756-PM-SO0206-001 19
5.2 Example of Pattern Program Creation
Note
(4) Creation of Placement Data (P-data) U01
Unit Control
Set the same parameters as in "Volume 3: Programming and Ma-
chine Data, Section 2, 3.1 Single Pattern" in the instruction manual
for the main machine.
Unit P.C.B. B.B.R.
Set "Disable" in this text box.
Do not set any parameter in the other text boxes.
Placement Data (P-data)
Table 6
P-No. X [mm] Y [mm] Z H [mm] Fdr. No. C S HD PU V Comment
1 BX
1
BY
1
000°00 +0.00 000 B - 0 0 00
2 X
1
Y
1
000°00 +0.00 101 - - 2 0 00
3 X
2
Y
2
090°00 +0.00 115 - - 1 0 00
4 X
3
Y
3
180°00 +0.00 105 - - 2 0 00
5 000.00 000.00 000°00 +0.00 000 P - 0 0 00
(a) Set the coordinates (BX
1
, BY
1
) of the bad mark in the "X
[mm]" and "Y [mm]" text boxes and "B" (control com-
mand) in the "C" text box of the "P-No. 1" step.
(b) Set "P" or "Q" as a control command in the last line (last
step No.).
(5) Creation of Placement Data (O-data) U01
Table 7
O-No. X [mm] Y [mm] Z H C Comment B-X [mm] B-Y [mm]
1 OX
1
OY
1
000°00 +0.00 - 000.00 000.00
2 OX
2
OY
2
000°00 +0.00 - 000.00 000.00
3 OX
3
OY
3
000°00 +0.00 - 000.00 000.00
4 000.00 000.00 000°00 +0.00 E 000.00 000.00
Tg0756-PM-SO0206-001 20
5.3 "Pattern Program" Edit Window
5.3 "Pattern Program" Edit Window
5.3.1 "P.C.B. Data" Tab
Sheet Layout
When the "P.C.B. Data" tab is pressed in the "Operation Data" tab
sheet, the following tab sheet appears.
*1
*2
Fig. 22 "P.C.B. Data" Tab Sheet
Sheet Composition
Each parameter is displayed or can be entered.
*1 Unit P.C.B. B.B.R.
Mode
Image, Component prechuck mode, Sequence
When a parameter other than "Disable" is selected for "Mode",
it is required to enter parameters in the text boxes.
*2 Overall P.C.B. B.B.R.
X [mm] (Horizontal), Y [mm] (Vertical)
When "Enable" is selected for "Overall P.C.B. B.B.R.", it is re-
quired to enter parameters in the text boxes.
Tg0756-PM-SO0206-001 21
5.3 "Pattern Program" Edit Window
*1
5.3.2 "O-data" Tab
Sheet Layout
When the "O-data" tab is pressed in the "Placement Data" tab sheet,
the following tab sheet appears.
Fig. 23 "O-data" Tab Sheet
Sheet Composition
Each parameter is displayed or can be entered.
*1 B-X [mm], and B-Y [mm]