Tg0756-PM-SO 0206-001 23 5.4 Program Change 5.4 Program Change Change to the current pattern program (the program for current pro- duction) and perform the setup operation. Refer to the main machine instruction manual fo…

100%1 / 33
Tg0756-PM-SO0206-001 22
Operation Procedure
New Creation of "O-data" Tab
(1) When the second toolbar is not visible, press the [Open 2nd.
Toolbar] icon
[ ] to make the second toolbar visible.
(2) Select the "U#" tab where an "O-data" tab should be added with
the touch screen or pointing device.
(3) When the [Add O-Data] icon
[ ] is selected, a new "O-data"
tab is added.
Deletion of "O-data" Tab
(1) When the second toolbar is not visible, press the [Open 2nd.
Toolbar] icon
[ ] to make the second toolbar visible.
(2) Select the "U#" tab where an "O-data" tab should be deleted with
the touch screen or pointing device.
(3) When the [Delete O-Data] icon
[ ] is selected, the "O-data"
tab of the selected U data is deleted.
5.3 "Pattern Program" Edit Window
Tg0756-PM-SO0206-001 23
5.4 Program Change
5.4 Program Change
Change to the current pattern program (the program for current pro-
duction) and perform the setup operation.
Refer to the main machine instruction manual for details.
5.5 Sensitivity Setting of Bad Mark Sensor
When the unit P.C.B. B.B.R. detection function is used, be sure to ad-
just the amplifier sensitivity of the sensor.
Procedure for Amplifier Sensitivity Adjustment
(1) Change to the current pattern program (the program for current pro-
duction) and perform the setup operation.
(2) Put a bad mark on the P.C.B. to be produced.
To put a black mark
Put a bad mark on the specified position of the second unit P.C.B.
Note: Do not put any bad mark on the first unit P.C.B.
To put a white mark
Put a bad mark on the specified position of the first unit P.C.B.
Note: Do not put any bad mark on the second unit P.C.B.
(a) Use a black mark for a comparatively bright P.C.B. (P.C.B.
with a lot of light reflex).
Use a white mark for a comparatively dark P.C.B. (P.C.B.
with a little light reflex).
(b) When the selection is changed (from "Black Mark" to "White
Mark" or vice versa), be sure to change the mark image
("Black (E/NR)" or "White (E/R)") in the "Image" text box
of the pattern program data.
Note
Tg0756-PM-SO0206-001 24
5.5 Sensitivity Setting of Bad Mark Sensor
(3) Set the product P.C.B. on the P.C.B. positioning section.
(4) Set the parameters at the operation window.
Press the [Unit Adjustment] button on the "Maintenance" sub-menu
bar and then press the [Bad Mark Sensor Sensitivity Setting] tab.
Fig. 24
(5) Select the [Head #1] button in the *1 "Select Unit".
(6) Press the *2 [Move XY Beam] button.
Fig. 25 Manual Alignment
*2
*6
*3
*5 *4
*1