18 Placement Heads SIPLACE SX1/SX2 SIPLACE MultiStar (CPP) Increased performance and flexibility The SIPLACE Multistar is the perfect SIPLAC E solution: • In an increasingly complex production environme nt • For an in cr…

17
Placement Heads SIPLACE SX1/SX2
SIPLACE MultiStar (CPP)
SIPLACE MultiStar
component camera type 30 (CPP)
SIPLACE MultiStar
component camera type 33(CPP)
Component range
a
a) Please note that the placeable component range is also affected by the pad geometry, the customer-spe-
cific standards, the component packaging tolerances and the component tolerances.
01005 to 27 mm x 27 mm 0402 to 50 mm x 40 mm
Component spec.
max height
b
max. height
c
min. lead pitch
min. lead width
min. ball pitch
min. ball diameter
min. dimensions
max. dimensions
max. weight
b) CPP head: in low installation position (stationary component camera not possible).
c) CPP head: in high installation position
6.0 mm
8.5 mm
0.3 mm
0.15 mm
0.25 mm
d
0.35 mm
e
0.14 mm
d
0.20 mm
e
0.4 mm x 0.2 mm
27 mm x 27 mm
4 g
d) For CO < 18 mm x 18 mm
e) For CO ≥ 18 mm x18 mm
11.5 mm
0.3 mm
0.15 mm
0.35 mm
0.2 mm
1.0 mm x 0.5 mm
50 mm x 40 mm
8 g
Programmable set-down
force
1.0 - 10 N 1.0 - 10 N
Nozzle types 20xx, 28xx 20xx, 28xx
X/Y accuracy
f
f) Accuracy values measured in accordance with vendor-neutral IPC standard.
± 41 µm/3
± 55 µm/4
± 34 µm/3
± 45 µm/4
Angular accuracy ± 0.4° / 3
g
, ± 0.5° / 3
h
± 0.5° / 4
g
, ± 0.7° / 4
h
g) Component dimensions between 6 mm x 6 mm and 27 mm x 27 mm.
h) Component dimensions smaller than 6 mm x 6 mm.
± 0.2° / 3
± 0.3° / 4
Illumination levels 5 6
Possible illumination
level settings?
256
5
256
6

18
Placement Heads SIPLACE SX1/SX2
SIPLACE MultiStar (CPP)
Increased performance and flexibility
The SIPLACE Multistar is the
perfect SIPLACE solution:
• In an increasingly complex
production environment
• For an increasing diversity
of setup and production
strategies
• For a wide spectrum of
components
• For frequent product
changeovers.
It is even possible to place
larger components without a
noticeable drop in perfor-
mance. The SIPLACE Multi-
star is perfectly designed for
integration into a flexible and
speed-optimized production
environment.
One head for all applica-
tions
• The SIPLACE MultiStar
offers top flexibility
• It combines
Collect&Place mode with
Pick&Place mode
One head supports three
placement modes:
Elimination of bottlenecks
• A wider component spec-
trum
• Optimum performance uti-
lization
• More feeder tracks for the
TwinStar
• Improved throughput due
to perfect line utilization
• More products in one set-
up family
Throughput
• Up to 23,000 components/
h benchmark value
• Up to 19,000 components/
h IPC 9850 performance
Collect&Place mode
Pick&Place mode
Mixed mode

19
Placement Heads SIPLACE SX1/SX2
SIPLACE TwinStar (TH)
SIPLACE TwinStar
Fine-pitch camera
(component camera type 33)
SIPLACE TwinStar
Flip chip camera (option)
(component camera type 25)
Component range
a
a) Please note that the placeable component range is also affected by the pad geometry, the customer-specific standards, the
component packaging tolerances and the component tolerances.
0402 to SO, PLCC, QFP, BGA, special
components, bare dies, flip-chips
0201 to SO, PLCC, QFP, sockets,
plugs, BGA, special components, bare
dies, flip-chips, shields
Component specs
b
max. height
c
min. lead pitch
min. lead width
min. ball pitch
min. ball diameter
min. dimensions
max. dimensions
max. weight
d
b) If the MultiStar and TwinStar are combined in the same placement area, the maximum component height may be restricted.
c) Max. component height 30 mm, Very High Force Pick&Place (VHF) or nozzle type 508 available on request
d) If standard nozzles are used.
25 mm
0.3 mm
0.15 mm
0.35 mm
0.2 mm
1.0mm x 0.5mm
55 mm x 45 mm (single measurement)
For operation with two nozzles:
50 mm x 50 mm or 69 mm x 10 mm
For use with one nozzle:
78 mm x 78 mm or 110 mm x 10 mm
up to 200 mm x 110 mm (with restrictions)
100 g
25 mm
0.25 mm
0.1 mm
0.14 mm
0.08 mm
0.6mm x 0.3mm
16 mm x 16 mm (single measurement)
55 mm x 55 mm (multiple measure-
ment)
100 g
Programmable set-down
force
1.0 N - 15 N
2.0 N - 30 N
e
2.0 N - 70 N
f
e) SIPLACE High-Force Head.
f) Very High Force Pick&Place (VHF) available on request
1.0 N - 15 N
2.0 N - 30 N
e
2.0 N - 70 N
f
Nozzle types
g
g) Over 300 different nozzles and 100 gripper types are available, with an extensive nozzle database available online.
5xx (standard)
4xx + adapter
8xx + adapter
9xx + adapter
gripper
5xx (standard)
4xx + adapter
8xx + adapter
9xx + adapter
gripper
Nozzle spacing for P&P
heads
70.8 mm 70.8 mm
X/Y accuracy
h
h) Accuracy values measured in accordance with vendor-neutral IPC standard.
± 26 µm/3± 35 µm/4 ± 22 µm/3± 30 µm/4
Angular accuracy ± 0.05° / 3± 0.07°/ 4 ± 0.05° / 3± 0.07° / 4
Illumination levels 6 6
Possible illumination level
settings
256
6
256
6