54 Technical Data SIPLACE SX1/SX2 Electrical Ratings, Energy Consumption and Compressed Air Supply Electrical ratings Supply voltage Fuses Main power supply 3 x 200 V~ ± 10 %; 50 Hz (North Japan) 3 x 220 V~ ± 10 %; 60 Hz…

53
Technical Data SIPLACE SX1/SX2
Siemens Signal Interface
Signal Path
1. After switching on the station
Direction of transport
Conveyor n Conveyor n+1
PCB sensor PCB sensor
Station n transports PCB
to transfer position
Conveyor n running Conveyor n+1
Request
Transferred
Permission
Arrived
Request
Transferred
Permission
Arrived
Station n+1
is ready to receive
0
0
1
0
2. PCB transfer has started
Direction of transport
Conveyor n Conveyor n+1
PCB sensor
Station n transfers
PCB to station n+1
Conveyor n running Conveyor n+1 running
Request
Transferred
Permission
Arrived
Request
Transferred
Permission
Arrived
Station n+1 expects
PCB from station n
1
0
1
0
3. PCB is transferred
Direction of transport
Conveyor n Conveyor n+1
PCB sensor PCB sensor
Station n has just trans-
ferred PCB
Conveyor n stopped Conveyor n+1 running
Request
Transferred
Permission
Arrived
Request
Transferred
Permission
Arrived
Station n+1 expects PCB
from station n, PCB has
not yet arrived
0
1
1
0
PCB sensor
4. PCB transfer has been completed
Direction of transport
Conveyor n Conveyor n+1
PCB sensor PCB sensor
Station n
Conveyor n stopped Conveyor n+1 running
Request
Transferred
Permission
Arrived
Request
Transferred
Permission
Arrived
Station n+1
PCB has arrived
0
0
0
1

54
Technical Data SIPLACE SX1/SX2
Electrical Ratings, Energy Consumption and
Compressed Air Supply
Electrical ratings
Supply voltage Fuses
Main power supply
3 x 200 V~ ± 10 %; 50 Hz (North Japan)
3 x 220 V~ ± 10 %; 60 Hz (South Japan)
3 x 208 V~ ± 10 %; 50/60 Hz (U.S.A)
3 x 230 V~ ± 10 %; 50/60 Hz
3 x 380 V~ ± 10 %; 50/60 Hz
3 x 400 V~ ± 10 %; 50/60 Hz (Europe)
3 x 415 V~ ± 10 %; 50/60 Hz
3 x 25 A to max. 3 x 32 A characteristic C
3 x 25 A to max. 3 x 32 A characteristic C
3 x 25 A to max. 3 x 32 A characteristic C
3 x 25 A to max. 3 x 32 A characteristic C
3 x 16 A characteristic C
3 x 16 A characteristic C
3 x 16 A characteristic C
Power connector
Cable 5 x 4 mm² 5 x 32 A (3 x 200 V~ / 208 V~ / 220 V~/ 230 V ~)
Cable 5 x 4 mm² with CEKON connector 5 x 16 A (3 x 380 V~ / 400 V~ / 415 V~/ V ~)
Energy consumption
Energy consumption
without vacuum pump
Energy consumption
with vacuum pump
a
a) Vacuum pump for C&P20 head only.
Nominal apparent
power
SIPLACE SX1
SIPLACE SX2
1.8 kVA
2.4 kVA
3.0 kVA
3.6 kVA
Nominal active
power
SIPLACE SX1
SIPLACE SX2
1.2 kW
1.6 kW
2.0 kW
2.4 kW
Compressed air supply
Compressed air
pressure values
p
min
p
max
0.5 MPa = 5.0 bar
1.0 MPa = 10 bar
Operating pressure
0.48 MPa ± 0.025 MPa (4.8 bar ± 0.25 bar)
Compressed air con-
nection
R 3/4" internal thread (pipe thread) with 1/2" hose connector
Compressed air consumption
b
b) Average consumption values.
Placement head
configuration
Compressed air
consumption?
c
without vacuum pump
c) Under normal atmospheric conditions at 20°C and 1013 hPa.
Compressed air consumption
c
with vacuum pump
a
SIPLACE SX2
SIPLACE SX1
C&P20 / C&P20
CPP / CPP
CPP / TH
TH / TH
C&P20
CPP
TH
490 Nl/min
240 Nl/min
240 Nl/min
200 Nl/min
280 Nl/min
140 Nl/min
100 Nl/min
200 Nl/min
–
–
–
100 Nl/min
–
–
Compressed air specification according to ISO 8573
Particle size (ISO class 3)
5 µm
Particle density (ISO class 3)
5 mg/m³
Maximum oil content
(ISO class 1)
Particle density 0.01 mg/m³
Pressure dewpoint (ISO class 4)
Dewpoint + 3°

55
Technical Data SIPLACE SX1/SX2
Electrical Ratings, Energy Consumption and
Compressed Air Supply
1 = Electrical connection
2 = Compressed air connection
The connections are run into the machine from below and then connected to the power
supply of pneumatic unit.