80S20 circuit.pdf - 第82页

3 SIPLACE 80S-20 Circuit Diagrams 82 00321510-070201 TD3 T erminal panel (right -hand side) L3 N 1 X 18 X X XX X C 23 4 7 L1 56 X207 A 10 10 N N X 13 17 18 6 11 12 19 X X X PE B A 420,0mm F L2 X2rd L3 L3 X1re 4 D E F C X…

100%1 / 138
3 SIPLACE 80S-20 Circuit Diagrams 81
00321510-070201LD3 Terminal panel (right-hand side) (voltage rectification)
=
SIEMENS AG
+
Terminal panel
To
Servo unit
To
Servo unit
To
Tape cutter 1
To To
Tape cutter 2
To
Servo
Star point 007
wh
bl&bk
bl&bk
bl&bk
0.5mm²
6L+ unswitched
+7L switched
+7L switched
6L+ unswitched
4.7 Ohm / 5W
bk
bk
1.0mm²
1.5mm²
To
To
WPC interface
righth. side 00322105
lefth. side, 00322104
WPC interface
Power supply
To
Power supply
VI rectifier
To
in SIPLACE 80F4 machines only
WPC interface:
To
Control unit
To interface To interface
lefth. side righth. side
To
Power supply
Power supply
SC
To
Option:
From UPSTo UPS
bn
bn
gn
gn
wh
wh
bk bk
wh
gy
bk
1.5mm²bk
bn
gn
ye
gy
pk
bl
wh
Spare
bl&bk
bl&bk
bl&bk
gn
bk bk
wh
wh
gn
gn
wh
wh
wh
gn
ye
gy
wh
bn
bn
gy
ye
wh
pk
gy
bk
gn&ye
gn&ye
bk
gn&ye
gn&ye To servo unit
To control unit
To cable
To cable
bn
bl
gn&ye
bn
bl
gn&ye
wh
pk
bk
wh
wh
bl
bn
gn&ye
bl
bkbk
bl
bl
bl
rd
bn
gy
wh
bn
bn
bn
gn&ye
gn&ye
gn&ye
gn&ye
gn&ye
bl
bn
gy
gn&ye
rd
wh
bn
wh
wh
gn&ye
bn
bl
gn&ye
gn&ye
bl
bk
bn
bk
gn&ye
bk
bk
bn
bk
bl
When using
a UPS, connect
the cables and
remove jumper
X206:4-5 !
00322063 00322064
00321510-070201LD3#
Tuth
21.10.98
08.06.98
01.06.00
21.10.98
01
02
07
Leh
Tu.
Leh
00321496-W100300161-0600300170-W1 00322067 00322068
00324356-W1
00321086
1
X1
11
4
1
2
(K1)
2
12V
4
6
2L-
1mm²
1mm²
1mm²
00321480
5
7L+ 10
6L+ 9
PE
2
(K2)
5
2
1L-
B
2
(K2)
(+24V)
4
1
1
456
123 456 78
17
2L+
9
X206:L1
3456
X206:L2
(rd) (re)
X2
X1
1
(K1)
34 56
123 456 7
1mm²
N
X2
X2
PEPEPEPE
X1
12
NN
56
L2 L3L1
3
L1 4L3 L3L2L2 6
1413 15 16
2L+
1L+ 11
12
1L+ 2
2L+ 3
10mm²
1mm²
89
(rc)
6
4
X206
X207
1
5
00315060
2
00313400
00313400
00315060
00324087
5L+
PE PE
1L+
1L+
1L+
1L+
(rb)
PEPENN 5
(+24V)
L1
2L+/5L+
2L+/5L+
2L-
1L-
1L+ 4
1L+ 1
7
10mm²
00324359-W1
6
3
3
2
6mm²
6mm²
C709
C708
X31
00324087/X16
2L+
2L-
2
9
8
D
7
C
A
6
00322110-W1
10
8
3
5
56
1mm²
F
342
2
B
A
1
1
1
8
4L+
18 8 8
1mm²
5
10 19 11
1
4
72345
12
X1
12398711
4
76
3
C
D
E
00344540
E
F
00344539
4
1mm²
7
X1
PEN5PEN4
00324358-W1
10 10
6
6L+ 9
7L+ 10
2L+/5L+
3
1
2L-
5
2
1mm²
2L-
00321535
6
1
7
3
21
6
L3 PE
*904/X211,X212
00306880-W1
(K2)
00321480/X3
00300164-W1
00321480/X2
00300163-W1
2L- 8
00322109-W1
(K1)3L+ 5
X206:PE
X206:N
X206:L3
X206:L2
X206:L1
X206:PE
X206:N
X206:L3
18
89
A2
A3 A4 A5
34
L1 L2
R1
21
PL EA1 E
Function status
Product status
Document status
SMD Placement System SIPLACE 80S20/F4
Sheet
Sh.
Status Modified Date Name Stand.
Check.
Author
Date
Orig. Creat. f. Creat. by
Terminal panel, righthand side
3 SIPLACE 80S-20 Circuit Diagrams 82
00321510-070201TD3 Terminal panel (right-hand side)
L3
N
1
X
18
XX
XX
X
C
234 7
L1
56
X207
A
10
10
N
N
X
13
17
18
6
11
12
19
X
X
X
PE
B
A
420,0mm
F
L2
X2rd
L3
L3
X1re
4
D
E
F
C
X
14
15
16
5
315,0mm
5
D
L2
2
B
C
5
6
4
PE
PE
10
X1rc X1rd
XX
2 6
PE
PE
PE
A4
A5
X2rb X2rc
3
X1rb
AA-BBBB-CCCC
N
PE
PE
00321510-07
SIEMENS PLEA 1
A
B
1
END
E
D
500,0mm
XX
XXX
L1
78
252,0mm
190,0mm
N
L2
8
XX
X206
1
8
9
3
L1
L1
PE
PE
N
40
20
4
A2 A3
1
7
8
1
L3
01
01
07
Leh
Leh
Leh
XX
116,0mm
XX
L2
PL EA1 E
00321510-070101TD3
#
Tuth
21.10.98
08.06.98
08.06.98
21.10.98
Function status
Product status
Document status
SMD Placement System SIPLACE 80S20/F4
Sheet
Sh.
Length for cable ducts +/- 5mm !
Please note:
Terminal panel, righthand side
Font size: 2.5mm, material: Scotchcal 3698-E (color: A1 RAL 9006)
BBBB = date (year/month/day) acc. to SN 01007
AA = manufacturer/location acc. to SN 37040
Assembly inscription acc. to VA - F - 510 - 001 guideline
CCCC = series number
Creat. by
D: space for voltage label from NAFTA – label set (for USA only)
B: inspection label
A: identification label
C: ground label
Identification: testing engineer, month, year
Orig. Creat. f.Stand.
Check.
Author
Date
NameDateModifiedStatus
The following labels have to be applied:
to 4L+ (8V),
This way you will switch from 1L+ (100V)
and insert it at X207 11-12-13-14-15.
remove the jumper from X207 13-14-15-16-17
- when commissioning the X,Y axes the first time
thus reducing the crash risk.
Please note:
Ground connection
acc. to constructions specs 00343603, sh.2
0.0mm
35.0mm
Screw
SN 70093 contact washer
DIN 439 nut
Annular cable lug
DIN 125 washer
DIN 7980 split washer
DIN 439 nut
Please note: Break off one rib at each X !
Cable duct: 65x66 l=460mm
Cable duct: 65x66 l=340mm
Please note: break off one rib at each X !
80.0mm
30.0mm
230.0mm
Cable duct: 65x46 l=400mm
Please note: Break off one rib at each X !
Cable duct: 65x46 l=400mm
Please note: Break off one rib at each X !
110.0mm
=
SIEMENS AG +
3 SIPLACE 80S-20 Circuit Diagrams 83
00344265-020101LD3 Terminal panel (left-hand side) (Sh. 1 of 2)
=
SIEMENS AG
+
00303614-xx
2
86kg
00322069 00322070
3
(00321421-xx)
2kb
2kb
X210
5kg
2kf
2
X
00321417-xx
00305815-xx
X
3
2kf
2kf
2kf
2ka
7
X2kd +
GND
+2kd
00321573-xx
3
X
X
X
X
00321434-xx
1
00321509-xx
00321529-xx
5
11-12 X211
X
8
2ka
2kf
GND
X
X
5
X
5ki
X5ki
GND
X210
D
2kb
+24V
X212
X
2kf
5
X
7
6
A
B
C
D
C
B
A
7
2
2kc
2kc 3
7
X
2kf
00321528-xx
7
X5ki 8
F
+24V
GND
IcosMC1
M44
X211
1
12
3
16
E
F
19
E
2kf
GND 24V
+24V
6kg
4
315
00322356-xx
00301486-xx
00317579-xx W1
4
+
00305816-xx
X210
3
1
7
16 17
6
X7
X8
2ka
2ka
X
+24V
+24V
+24V
+24V
2kd
311
X211
5ki
17
61 8
818
X211
00317579-xx W2
+
X2kf 2
X
5
2ka
00321433-xx
X211
GND
32
2kb
5
X
8
2kd
18
00321432-xx
+X
2ka
X
5
2kd
5kg 6
X5kg 7
5
6kg
89
00326069-01
10 11
23
X
6
X6
00321416-xx
00321574-xx
5
00321436-xx
00321529-xx
+24V
X
X6kg
192
12
2kd
X
2kf
X
00326068-01
82kb
X+2kd
X+
2kd
X
6
X4
910
34
6
GND
-
X-
X+
X
X
X
2kc
2ka
X
X
GND
GND
7
X
2kb
2kb
X5
-xx
1
-
X2kc
314221 4
2
X1
2kd
GND
2kd
X
X5
2ka
6
2kd
4
00321528-xx
2kd
4
X
X
4
2kc
3
X-
2kf
2kf
X
2kf
6
2kd +24V
X+
-xx
2ka
00321587-xx
00321588-xx
X4
X3
2kd
X
25
00322070-xx
2kf -
+
X
2kc 1
3
-
X2kc 5
X
*(00344226-xx)
*(00344225-xx)
X2kd
2
X
6
00322069-xx
+24V
+24V
+
-
X-
X
01
01
02
Leh
Ha
Ha
11
5
X210
PL EA1 E5
00344265-020101LD3
#
Haas
02.09.99
02.10.98
02.09.99
02.09.99
Date
Check.
Author
Creat. byCreat. f.Orig.NameModified DateStatus Stand.
Sh.
Sheet
SMD Placement System SIPLACE 80S20/S23
Document status
Product status
Function status
Circuit diagram, terminal panel
lefthand side
Emerg.-stop button
Start button
Cover open
From signaling circuit, Emerg.-stop button
From signaling circuit, Start button
+24V (CO-table 1-4)
From control circuit, Stop button
Keyswitch
From feeder crash sensor, left CO-table, S1
From control circuit, Emerg.-stop button
To control circuit, Emerg-stop button
To control circuit, Emerg.-stop button
To control circuit, Emerg.-stop button
To control circuit 1, START button
From control circuit 1, START button
To control circuit 2, START button
From control circuit 2, START button
To keyswitch
From CO-table (E-S-L)
From keyswitch
To CO-table (E-S-L)
From WP changer (E-S-L)
lbl
wh
bn
gy
gn
ye
pk
bn
lbl
bn
wh
bn&gn
bn
wh&ye
vio
bk
rd&bl
rd
gn
ye
gy&pk
Lifting table 1, up
Lifting table 1, down
Crash, gantry 1
Distance sensor
Nozzle changer 2, shut
Valve, nozzle changer 2
Nozzle changer 2, open
Valve, nozzle changer 1
Nozzle changer 1, shut
Nozzle changer 1, open
Fault indicator lamp
Fault indicator lamp
Fault indicator lamp
Compressed air sensor
wh
ye
pk
bl
wh
wh
bn
bn
wh
wh
bn
gn
bn
bl
rd
pk
wh
bn
ye
rd
gn
bn
gn
ye
bn
wh
pk
ye
gn
gy
ye
bk
gn
gy&pk
rd
bn
bn
vio
wh
wh
From signaling circuit, protective switch 2
From signaling circuit, protective switch 1
STOP button
To control circuit 2, START button
From control circuit 2, START button
To control circuit 1, START button
From control circuit 1, START button
From signaling circuit, Emerg.-stop button
To signaling circuit, Emerg.-stop button
From control circuit, Start button
From signaling circuit, Start button
To signaling circuit, Start button
Extend stopper 2 valve
Extend stopper 1 valve
Valve, ceramic substrate centering 1
Ultrasonic sensor, center conveyor 1
Ultrasonic sensor, center conveyor 2
Signal "lifting table 1 down"
Prox. switch, pos. width adjustment 1
Signal: end width adjustment 1
Prox. switch, ceram. substrate centering 1
Prox. switch, stopper 1 ON
Prox. switch, stopper 2 ON
Signal "lifting table 1 up"
Motor, width adjustment 2, wider
Motor, width adjustment 2, narrower
Motor, width adjustment 2, fast
Motor, width adjustment 1, narrower
Motor, width adjustment 1, wider
Motor, width adjustment 1, fast
gy
gy&pk
pk
bl
bn
rd&bl
rd
bk
vio
gn
pk
rd
bk
wh
bl
ye
gy
wh
gn
bn
ye
Ultrasonic sensor, input conveyor 1
Ultrasonic sensor, output conveyor 1
Ultrasonic sensor, output conveyor 2
Ultrasonic sensor, input conveyor 2
Valve, ceram. substr. centering 2
vio
gy&pk
rd&bl
wh&gn
To control circuit, prot. switch 4
From signaling circuit, protective switch 4
From control circuit, prot. switch 4
From signaling circuit, protective switch 3
From control circuit, prot. switch 3
To control circuit, prot. switch 3
To control circuit, prot. switch 2
From control circuit, prot. switch 2
To control circuit, prot. switch 1
From control circuit, prot. switch 1
gn
wh
bn
bn
wh
ye
ye
ye
gn
ye
gn
gn
00322333-xx
To video
multiplexer
Pneumatic system
00300912-xx
fault indicator
To main
00318689-xx
To
Conversion board
Conversion board
Gantry 1
changer 2
Nozzle
Control board
Control board
changer 1
Nozzle
To
To
To
To
Gantry 2
PCB 1/2 conveyor control
Conversion board
Lifting table, X13
To
Lifting table, X12
Conversion board
PCB 1/2 conveyor control
To
1.5mm²
wh
* Please note:
in brackets
apply to the F5-HM machine.
The numbers
Operator panel
To
(Output conveyor)
Operator panel
(Output conveyor)
To
0.5mm²
bl/bk
bl/bk
bl/bk
bl/bk
righth. sidelefth. side
Interfaces
Component table
Operator panel
(Input conveyor)
To
(Input conveyor)
Operator panel
To
Hood switch
righth. side
Hood switch
lefth. side preceding station
Hood switch optionHood switch
Input conveyor
Warning!
(connection rail)
the jumper
If the cable is connected
has to be removed.
sheet 2
Continued on