00198235-02_VD_710.1_R17-1_DE_EN.pdf - 第19页

Station Software 71 0.1 (R17 - 1) / Versio n Description 06/2017 Edition 19 8 Corrected Error s 710. 1 Station So ftware The 710. 1 stat ion software versio n contains all erro r corrections of the prev ious 701.x – 7 10…

100%1 / 58
Station Software 710.1 (R17-1) / Version Description 06/2017 Edition
18
7 Restrictions
For details concerning possible machine configurations, please consult the latest version of the
machine specification.
Restrictions to features in previous versions can be found in the Station Software V7xx Feature
Description, item no. [00197741-xx].
Station Software 710.1 (R17-1) / Version Description 06/2017 Edition
19
8 Corrected Errors
710.1 Station Software
The 710.1 station software version contains all error corrections of the previous 701.x – 710.x
versions. Additionally, the following errors have been corrected in this version:
Error no. Error description
D1-129558314 On WPC6, the components lie below the top edge of the tray.
D1-132588701 Level cannot be refilled on WPC6; level is already on feed axis.
D1-133168801 During production with the Twin VHF head, the CPP head moved to the
placement area and swept away big components from the board.
D1-134664001 The support pins were not put back on the lifting table after having been
returned to the magazine.
D1-134727901 GUI message was incorrect for the Pin Picker endurance run.
D1-135587801 Pin 1 detection for symmetrical components was not possible.
D1-136197701 Software hung up after a USB stick was inserted in the computer.
Table 8-1: Corrected errors station software version 710.1
710.0 Patch 4
Fehlernummer Fehlerbeschreibung
D1-135456343 The yellow signal lamp got active after a track error but was not switched off
after having fixed the problem.
D1-135712643 After having opened and closed the safety circuit the machine dids not make a
reference run but displayed
Waiting for board
.
D1-136308201
Head verification: CPP verification reported an error.
D1-136508382
D1-136522830
eSW: TX2i with CPP/CP20P: The CPP head was not recognized automatically
after the first machine start.
D1-136529501 The station sent filling level events too often (every 5 seconds).
D1-136683901
eSW: the LBO mode did not work along with an SX4 machine.
D1-136983401 eSW: LBO with backward stopper sporadically did not work in PA1 on an SX4
machine.
D1-137831501 eSW: Borad moved into second station and stayed in input conveyor without
any error message.
D1-137977901 The machine stopped; start and stop buttons were not active and even a
hardware stop/start did not help.
D1-138067701 The machine stopped when an orientation check was carried out.
Station Software 710.1 (R17-1) / Version Description 06/2017 Edition
20
D1-138086439 After a setup change all pickup up positions were deactivated at the station.
D1-138513601
From version 709.1 on, barcode fiducials defined in sub-panels were ignored.
D1-138541501 The y axis MFU on gantry 2 / conveyor 1 had a curved result.
D1-138840001
D1-138564301
D1-138862989
D1-139192319
The operating hours were not counted correctly and in some cases reset to 0.
D1-138894801 eSW: Vacuum-tooling on TX widened track displayed an error during
clamping.
D1-138905901 There was an unhandled Windows exception during the Coplan MFU.
D1-138937301 Placement offset of a heavy component because the gantry moved with full
speed during gantry repression.
D1-138953601 Error messages 30506 Hardware warning dp axis and 30576
Unspecified hardware error 0xC
.
D1-138957949 eSW: Problems with width adjustment when the width was not changed for a
while.
D1-139000201
It was not possible to reject the nozzles when all magazines were occupied.
D1-139002101 The station software stopped during/after placement with the error message
30016 Unhandled exception error
.
D1-139126101 Although the tray was verified, the operator needed to push the correct
positions button to get the production started.
D1-139191953 Sporadically, the station software stopped during placement with the error
messages 30016 Unhandled exception error and 32602 The
software has stopped unexpectedly
.
D17667-16852 The machine stopped with the error message 36203 Machine is out of
memory
.
D17928-19601
D1-139010501
D1-139243601
F1-138458244
The software hung up when activating the image capture during pickup
correction.
D18199-6302 Testing a shield with local fiducial led to the error message 33325 Field of
view of camera is too small for measurement
.
D18199-7016 When a shield with local fiducial was tested, the searching range was limited.
D18218-9101 No error information was displayed on the GUI.
Table 8-2: Corrected errors station software version 710.0 Patch 4