00198235-02_VD_710.1_R17-1_DE_EN.pdf - 第20页

Station Software 71 0.1 (R17 - 1) / Versio n Description 06/2017 Edition 20 D1 - 138086439 After a setup change all pickup up posit ions we re deactiv ated at the station . D1 - 138513601 From version 709.1 on , ba rcode…

100%1 / 58
Station Software 710.1 (R17-1) / Version Description 06/2017 Edition
19
8 Corrected Errors
710.1 Station Software
The 710.1 station software version contains all error corrections of the previous 701.x – 710.x
versions. Additionally, the following errors have been corrected in this version:
Error no. Error description
D1-129558314 On WPC6, the components lie below the top edge of the tray.
D1-132588701 Level cannot be refilled on WPC6; level is already on feed axis.
D1-133168801 During production with the Twin VHF head, the CPP head moved to the
placement area and swept away big components from the board.
D1-134664001 The support pins were not put back on the lifting table after having been
returned to the magazine.
D1-134727901 GUI message was incorrect for the Pin Picker endurance run.
D1-135587801 Pin 1 detection for symmetrical components was not possible.
D1-136197701 Software hung up after a USB stick was inserted in the computer.
Table 8-1: Corrected errors station software version 710.1
710.0 Patch 4
Fehlernummer Fehlerbeschreibung
D1-135456343 The yellow signal lamp got active after a track error but was not switched off
after having fixed the problem.
D1-135712643 After having opened and closed the safety circuit the machine dids not make a
reference run but displayed
Waiting for board
.
D1-136308201
Head verification: CPP verification reported an error.
D1-136508382
D1-136522830
eSW: TX2i with CPP/CP20P: The CPP head was not recognized automatically
after the first machine start.
D1-136529501 The station sent filling level events too often (every 5 seconds).
D1-136683901
eSW: the LBO mode did not work along with an SX4 machine.
D1-136983401 eSW: LBO with backward stopper sporadically did not work in PA1 on an SX4
machine.
D1-137831501 eSW: Borad moved into second station and stayed in input conveyor without
any error message.
D1-137977901 The machine stopped; start and stop buttons were not active and even a
hardware stop/start did not help.
D1-138067701 The machine stopped when an orientation check was carried out.
Station Software 710.1 (R17-1) / Version Description 06/2017 Edition
20
D1-138086439 After a setup change all pickup up positions were deactivated at the station.
D1-138513601
From version 709.1 on, barcode fiducials defined in sub-panels were ignored.
D1-138541501 The y axis MFU on gantry 2 / conveyor 1 had a curved result.
D1-138840001
D1-138564301
D1-138862989
D1-139192319
The operating hours were not counted correctly and in some cases reset to 0.
D1-138894801 eSW: Vacuum-tooling on TX widened track displayed an error during
clamping.
D1-138905901 There was an unhandled Windows exception during the Coplan MFU.
D1-138937301 Placement offset of a heavy component because the gantry moved with full
speed during gantry repression.
D1-138953601 Error messages 30506 Hardware warning dp axis and 30576
Unspecified hardware error 0xC
.
D1-138957949 eSW: Problems with width adjustment when the width was not changed for a
while.
D1-139000201
It was not possible to reject the nozzles when all magazines were occupied.
D1-139002101 The station software stopped during/after placement with the error message
30016 Unhandled exception error
.
D1-139126101 Although the tray was verified, the operator needed to push the correct
positions button to get the production started.
D1-139191953 Sporadically, the station software stopped during placement with the error
messages 30016 Unhandled exception error and 32602 The
software has stopped unexpectedly
.
D17667-16852 The machine stopped with the error message 36203 Machine is out of
memory
.
D17928-19601
D1-139010501
D1-139243601
F1-138458244
The software hung up when activating the image capture during pickup
correction.
D18199-6302 Testing a shield with local fiducial led to the error message 33325 Field of
view of camera is too small for measurement
.
D18199-7016 When a shield with local fiducial was tested, the searching range was limited.
D18218-9101 No error information was displayed on the GUI.
Table 8-2: Corrected errors station software version 710.0 Patch 4
Station Software 710.1 (R17-1) / Version Description 06/2017 Edition
21
710.0 Patch 3
D1-135754107 Self-test of the station SW: the conveyor motor verification failed as the limits
were too high.
D1-137565101 The Twin head used only one segment although SIPLACE Pro scheduled the
job for both segments.
D1-137636212 The mapping data were not interpolated correctly.
D1-137641858 When checking the LED centering the z axis touched the glass plate and the
software hung up.
D1-137703301 eSW: Cogging force measurement failed due to oscillating gantries.
D1-137762253 There was an unknown hardware error at gantry 4 of the y axis.
D1-137781601 eSW: the conveyor width of conveyor 2 was not restricted although vacuum
tooling was used.
D1-138058601 The gantry offsets should be corrected automatically after having inspected
the chuck fiducials.
Table 8-3: Corrected errors station software version 710.0 Patch 3
710.0 Patch 2
Error no. Error description
D1-131965901 Wrong sequence after a "slope error".
D1-131982201 The "show current board only" function did not work properly.
D1-134286551 The progress bar for the board was missing on the GUI.
D1-134716501 Restarting a failed operation added the error to the error chain once again.
D1-135255401 Sporadically, there were communication problems between the station and
BoardGateKeeper when the barcode was read in the input section.
D1-135304701 Production could not be stopped; a restart of the software was required.
D1-135562301 The amount of discarded components or vision errors was ok at the station but
not in SetupCenter.
D1-135634601 The machine stood still after having taught components during production.
D1-135912817 The machine stopped without a reasonable error message.
D1-135955201 Sporadically, the software hung up when there were setups with a manual
tray.
D1-136159132 eSW: Timing problems along with C&P20 P head control.
D1-136244601 The feeder was still verified although there was a foil torn error.
D1-136286403
D1-137048101
D1-137327501
Location -> I/O settings: error message that there was an IPC communication
error.
D1-136302601 The machine stopped during endurance run with error message command
not implemented
.