TECHNICAL PUBLICATIONS
T46230812 Rev. D DH Positioning System Assembly, P/T
This Document Supports Assembly 46230812
4. Place the set up template on the rotary table beneath head 1 and secure
it in position using the locator pins and thumb screws.
5. Activate the IM Diagnostics as follows. Refer to the IM-UPS and IM
Diagnostics documentation for specific details relating to the operation
of the machine terminal.
Select the IM Diagnostics icon.
When the machine is in the IM Diagnostics function, power is provided
to the machine. Exercise caution when performing the following
procedures to avoid Injury to personnel and equipment.
6. After the IM Diagnostics has completed its initialization, select the
following. Diagnostics>Manual Diagnostics
The Manual Diagnostics screen is displayed
7. In the Outputs side of the Manual Diagnostics screen, select the
following. Section>UIMC 1 Axis Outputs
8. Palm the machine up and push the INTLK RESET push button.
9. Select Channel B: Table Y Axis>Zero
The Zero - Table Y Axis dialog screen is displayed.
Page 33
TECHNICAL PUBLICATIONS
DH Positioning System Assembly, P/T T46230812 Rev. D
This Document Supports Assembly 46230812
10. In the Zero - Table Y Axis dialog screen select Default then OK
The Manual Diagnostics screen is displayed.
- In the Channel B: Table Y Axis increment box, click on the up
or down ¯ arrows until 1.0 appears in the increment box.
- Click on the + Jog button until the Axis Location for the Table
Y Axis indicator in the Input side of the screen reads 9.0.
11. Select Channel A: Table X Axis>Zero
The Zero - Table X Axis dialog screen is displayed.
12. In the Zero - Table X Axis dialog screen select Default then OK
The Manual Diagnostics screen is displayed.
- In the Channel A: Table X Axis increment box, click on the up
or down ¯ arrows until 1.0 appears in the increment box.
- Click on the + Jog button until the Axis Location for the Table
X Axis indicator in the Input side of the screen reads 9.0.
13. In the Outputs side of the Manual Diagnostics screen, select the
following. Section>UIMC 2 Axis Outputs
Set up Tool in Outside Formers
Page 34
TECHNICAL PUBLICATIONS
T46230812 Rev. D DH Positioning System Assembly, P/T
This Document Supports Assembly 46230812
14. Select Channel A: DH Span Axis>Zero
The Zero - DH Span Axis dialog screen is displayed.
15. In the Zero - DH Span Axis dialog screen select Default then OK
The Manual Diagnostics screen is displayed.
- In the Channel A: DH Span Axis increment box, click on the up
or down ¯ arrows until 0.001 appears in the increment box.
- Click on the + Jog button until the Axis Location for the
Table Y Axis indicator in the Input side of the screen reads
0.397.
16. Insert the set up tool into the outside formers.