6-9-p0027-0080-vx21_en.pdf - 第10页

Size Orifice diameter (mmø) Note 1) Model Maximum operating pressure differential (MPa) Note 3) 1.0 0.6 0.2 1.0 0.15 1.0 0.3 2 3 5 4 7 5 7 1 2 3 C [dm 3 /(s·bar)] b 0.23 0.41 0.62 0.62 1.08 0.75 1.08 0.63 0.68 0.39 0.52 …

100%1 / 56
How to Order (Single Unit)
VX2
01 A A
Common Specifications
NBR
Class B
Rc
∗
Seal material
Coil insulation type
Thread type
For special options, refer to pages 49 to 51.
24 VAC
48 VAC
220 VAC
240 VAC
12 VDC
Special voltage
DIN terminal with light
Conduit terminal with light
Without DIN connector
Low concentration ozone resistant
(Seal material: FKM)
Seal material: EPDM
Oil-free
G thread
NPT thread
With bracket (Aluminum body only)
Mounting holes on the bottom side of the body
(Aluminum body only)
Special electrical entry direction
Coil size/Valve type
Body material/Port size/Orifice diameter
Voltage/Electrical entry
Size
Symbol
Size 1
Valve type
Symbol
A
B
C
D
E
F
H
J
K
L
M
N
1
4
Body
material
Orifice
diameter
2
3
5
2
3
5
2
3
5
2
3
5
1/8
1/4
ø6
ø8
Port
size
Symbol
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
Y
Z
Electrical entry
Other voltages
Voltage
24 VDC
100 VAC
110 VAC
200 VAC
230 VAC
24 VDC
24 VDC
100 VAC
110 VAC
200 VAC
230 VAC
24 VDC
100 VAC
110 VAC
200 VAC
230 VAC
24 VDC
100 VAC
110 VAC
200 VAC
230 VAC
24 VDC
Flat terminal
Grommet
Grommet
DIN terminal
Conduit terminal
Conduit
With surge
voltage
suppressor
With surge
voltage
suppressor
With surge
voltage
suppressor
With surge
voltage
suppressor
Aluminum
Resin
(With bracket)
A
B
C
D
E
F
G
H
J
K
L
M
N
5
8
10 (N.C. only)
5
8
10 (N.C. only)
10 (N.C. only)
5
8
10 (N.C. only)
5
8
10 (N.C. only)
1/4
3/8
1/2
ø10
ø12
Aluminum
Resin
(With bracket)
A
B
D
E
H
J
L
M
4
7
4
7
4
7
4
7
1/4
3/8
ø8
ø10
Aluminum
Resin
(With bracket)
N.O.
N.C.
Size 2
2
5
N.O.
N.C.
Size 3
3
6
N.O.
N.C.
Dimensions → Pages 56 to 59 (Single unit)
∗ One-touch fittings are attached
to the resin body type.
Fluid
0
Air
RoHS
RoHS
Direct Operated 2 Port Solenoid Valve
VX21/22/23 Series
Single UnitFor Air
®
Note) Refer to the table
on page 52 for
UL-compliant.
35
VX2
VXK
VXD
VXZ
VXS
VXB
VXE
VXP
VXR
VXH
VXF
VX3
VXA
VX2
A
Size
Orifice diameter
(mmø)
Note 1)
Model
Maximum operating
pressure differential
(MPa)
Note 3)
1.0
0.6
0.2
1.0
0.15
1.0
0.3
2
3
5
4
7
5
7
1
2
3
C [dm
3
/(s·bar)]
b
0.23
0.41
0.62
0.62
1.08
0.75
1.08
0.63
0.68
0.39
0.52
0.44
0.55
0.44
0.63
1.05
2.20
1.90
3.99
1.96
3.99
Cv
Flow rate characteristics
Note 2)
Normally Closed (N.C.)
VX2A0
VX2B0
VX2C0
Normally Open (N.O.)
Size
Orifice diameter
(mmø)
Note 1)
Model
Maximum operating
pressure differential
(MPa)
Note 3)
0.9
0.45
0.2
0.8
0.15
0.8
0.3
2
3
5
4
7
5
7
1
2
3
C [dm
3
/(s·bar)]
b
0.23
0.41
0.62
0.62
1.08
0.75
1.08
0.63
0.68
0.39
0.52
0.44
0.55
0.44
0.63
1.05
2.20
1.90
3.99
1.96
3.99
Cv
Flow rate characteristics
Note 2)
VX2D0
VX2E0
VX2F0
Common SUP type
2 (OUT)
1 (IN)
2 (OUT)
2 (OUT)
1 (IN)
2 (OUT)
1.0
Max. system pressure
(MPa)
Note 3)
1.0
When the valve is closed, flow is blocked from port 1 to port 2. However,
if the pressure in port 2 is higher than port 1, the valve will not be able to
block the fluid and it will flow from port 2 to port 1.
Model/Valve Specifications
VX21/22/23 Series
ManifoldFor Air
Symbol
N.C.
Common SUP type
N.O.
Symbol
Fluid and Ambient Temperature
Note) Dew point temperature: –10°C or less
Note 1) The orifice size is just as a reference guide. Check the flow rate characteristics (conversion Cv).
Note 2) The flow rate characteristics of this product have variations.
When the highly precise flow control is required according to the system to be used, select an orifice diameter 1.3 times larger than that shown
above and install a restrictor on the downstream side of the solenoid valve to make the adjustment.
Note 3) Refer to “Glossary of Terms” on page 65 for details on the maximum operating pressure differential and the maximum system pressure.
Ambient temperature (°C)
−20 to 60
Fluid temperature (°C)
−10
Note)
to 60
Valve Leakage Rate
Internal Leakage
Note 1) Leakage is the value at ambient temperature 20°C.
Note 2) For seal material/FKM, refer to “Other Options” on page 49 for the
selection.
Note 3) The amount of leakage is the value at a differential pressure of
0.01 MPa or more, and a temperature of 20°C.
External Leakage
NBR (FKM)
Seal material
Note 2)
Leakage rate
Note 1)
1 cm
3
/min or less
NBR (FKM)
Seal material
Note 2)
Leakage rate
Note 1)
1 cm
3
/min or less
Max. system pressure
(MPa)
Note 3)
36
B
VX2
0A A A
Common Specifications
NBR
Class B
Seal material
Coil insulation type
Coil size/Valve type
Body material/Orifice diameter
Voltage/Electrical entry
Symbol
Size
Size 1
Valve type
Symbol
A
B
C
A
B
A
B
A
D
N.C.
N.O.
Body
material
Orifice diameter
2
3
5
4
7
5
7
Symbol
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
Y
Z
Electrical entry
Other voltages
Voltage
24 VDC
100 VAC
110 VAC
200 VAC
230 VAC
24 VDC
24 VDC
100 VAC
110 VAC
200 VAC
230 VAC
24 VDC
100 VAC
110 VAC
200 VAC
230 VAC
24 VDC
100 VAC
110 VAC
200 VAC
230 VAC
24 VDC
Flat terminal
Grommet
Grommet
DIN terminal
Conduit terminal
Conduit
With surge
voltage
suppressor
With surge
voltage
suppressor
With surge
voltage
suppressor
With surge
voltage
suppressor
Size 2
B
E
N.C.
N.O.
Size 3
C
F
N.C.
N.O.
Resin
Resin
Resin
Dimensions → Page 63
VVX2
01 A 02
Coil size
Base material/Port size/Base type
Symbol
Size
Size 1
Size 2
Size 3
Symbol
A
B
1/8
1/4
1
2
3
Base
material
Base
type
Individual
port size
Aluminum
Common
SUP
Symbol
Nil
A
B
D
E
Z
Rc
G
∗
1
NPT
G
∗
1
NPT
Rc
—
—
—
Oil-free
Special
thread
Stations
Symbol
02
03
04
05
06
07
08
09
10
Stations
2 stations
3 stations
4 stations
5 stations
6 stations
7 stations
8 stations
9 stations
10 stations
Manifold Base/How to Order
Blanking Plate Assembly Part No.
How to Order Manifold Assembly (Example)
N
F
NBR
FKM
Seal material
For size 1
VVX021S 4A
For size 2
VVX022S 4A
For size 3
VVX023S 4A
When mounting a blanking plate
assembly, if the solenoid valve for
the manifold is ozone resistant,
(Seal material: FKM), please se-
lect FKM.
For special options,
refer to pages 49 to 51.
24 VAC
48 VAC
220 VAC
240 VAC
12 VDC
Special voltage
DIN terminal with light
Conduit terminal with light
Without DIN connector
Seal material: EPDM
Low concentration ozone resistant (Seal material: FKM)
Oil-free
Special electrical entry direction
Common port size: 3/8
(IN port)
N
N
N
Fluid
0
Air
Fluid
0
Air
How to Order (Solenoid Valve for Manifold)
Mounting orientation exists
when mounting valves onto
manifold base. Refer to page
76 for details.
Caution
∗1 For connection,
prepare a fitting
compliant with ISO
16030 and JIS B 8674.
Stations
D side
5 x Rc1/4
(Individual port)
<Example>
5
4
321
Stations
Enter the product’s part number in order, counting the 1st station from the D side
(left in the manifold arrangement, when viewing the individual port in front).
Enter the valve and blanking plate to be mounted under the manifold
base part number.
U side
D side
VVX210B05
………...
1
∗VX2A0AA ………….4
∗VVX021S-4A-N ……1
“∗” is the symbol for mounting.
Add an “∗” in front of the part numbers for solenoid
valves etc. to be mounted.
37
RoHS
Direct Operated 2 Port Solenoid Valve
VX21/22/23 Series
ManifoldFor Air
VX2
VXK
VXD
VXZ
VXS
VXB
VXE
VXP
VXR
VXH
VXF
VX3
VXA
VX2
B