How to Order (Single Unit) VX2 0 1 A A Common Specifications NBR Class B Rc ∗ Seal material Coil insulation type Thread type For special options, refer to pages 49 to 51. 24 VAC 48 VAC 220 VAC 240 VAC 12 VDC Special volt…

Port sizeSize
Orifice diameter
(mmø)
Note 1)
Model
Maximum operating
pressure differential
(MPa)
Note 4)
0.9
0.45
0.2
0.8
0.15
0.8
0.3
2
3
5
4
7
5
8
1/8, 1/4
1/4, 3/8
1/4, 3/8
1
2
3
C [dm
3
/(s·bar)]
b
0.23
0.41
0.62
0.62
1.08
0.75
1.58
240
240
240
370
370
490
490
0.63
0.68
0.39
0.52
0.44
0.55
0.33
0.63
1.05
2.20
1.90
3.99
1.96
5.67
Cv
Flow rate characteristics
Note 2)
Note 3)
Note 3)
VX240
VX250
VX260
VX240
VX250
VX260
Port sizeSize
Orifice diameter
(mmø)
Note 1)
Model
Maximum operating
pressure differential
(MPa)
Note 4)
0.9
0.45
0.2
0.9
0.45
0.2
0.8
0.15
0.8
0.15
0.8
0.3
0.8
0.3
0.82
1.25
1.45
0.82
1.81
2.11
1.69
3.14
1.68
3.54
2.50
2.77
2.50
2.56
2
3
5
2
3
5
4
7
4
7
5
8
5
8
ø6
ø8
ø8
ø10
ø10
ø12
1
2
3
C [dm
3
/(s·bar)]
b Cv
Flow rate characteristics
Note 2)
0.44
0.34
0.43
0.44
0.40
0.32
0.40
0.34
0.49
0.36
0.44
0.82
0.42
0.88
0.23
0.35
0.40
0.23
0.41
0.56
0.47
0.84
0.50
0.90
0.70
1.22
0.70
1.38
240
240
240
240
240
240
370
370
370
370
500
500
500
500
21
1.0
1.0
Note 1) The orifice size is just as a reference guide. Check the flow rate characteristics (conversion Cv).
Note 2) The flow rate characteristics of this product have variations.
When the highly precise flow control is required according to the system to be used, select an orifice diameter 1.3 times larger than that shown
above and install a restrictor on the downstream side of the solenoid valve to make the adjustment.
Note 3) Weight of grommet type. Add 10 g for conduit type, 30 g for DIN terminal type, 60 g for conduit terminal type respectively.
Note 4) Refer to “Glossary of Terms” on page 65 for details on the maximum operating pressure differential and the maximum system pressure.
AIuminum Body Type
Resin Body Type (Built-in One-touch Fittings)
When the valve is closed, flow is blocked from port 1 to port 2. However, if the pressure in port 2 is
higher than port 1, the valve will not be able to block the fluid and it will flow from port 2 to port 1.
For Air Single Unit
VX21/22/23
Series
Model/Valve Specifications
Symbol
N.O.
Fluid and Ambient Temperature
Note) Dew point temperature: −10°C or less
−20 to 60
Ambient temperature (°C)Fluid temperature (°C)
−10
Note)
to 60
Internal Leakage
Note 1) Leakage is the value at ambient temperature 20°C.
Note 2) For seal material/FKM, refer to “Other Options” on page 49 for the
selection.
Note 3) The amount of leakage is the value at a differential pressure of
0.01 MPa or more, and a temperature of 20°C.
External Leakage
NBR (FKM)
Seal material
Note 2)
Leakage rate (Air)
Note 1)
1 cm
3
/min or less (AIuminum body type)
15 cm
3
/min or less (Resin body type)
NBR (FKM)
Seal material
Note 2)
Leakage rate (Air)
Note 1)
1 cm
3
/min or less (AIuminum body type)
15 cm
3
/min or less (Resin body type)
Max. system pressure
(MPa)
Note 4)
Max. system pressure
(MPa)
Note 4)
Weight
(g)
Valve Leakage Rate
Weight
(g)
34
B

How to Order (Single Unit)
VX2
01 A A
Common Specifications
NBR
Class B
Rc
∗
Seal material
Coil insulation type
Thread type
For special options, refer to pages 49 to 51.
24 VAC
48 VAC
220 VAC
240 VAC
12 VDC
Special voltage
DIN terminal with light
Conduit terminal with light
Without DIN connector
Low concentration ozone resistant
(Seal material: FKM)
Seal material: EPDM
Oil-free
G thread
NPT thread
With bracket (Aluminum body only)
Mounting holes on the bottom side of the body
(Aluminum body only)
Special electrical entry direction
Coil size/Valve type
Body material/Port size/Orifice diameter
Voltage/Electrical entry
Size
Symbol
Size 1
Valve type
Symbol
A
B
C
D
E
F
H
J
K
L
M
N
1
4
Body
material
Orifice
diameter
2
3
5
2
3
5
2
3
5
2
3
5
1/8
1/4
ø6
ø8
Port
size
Symbol
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
Y
Z
Electrical entry
Other voltages
Voltage
24 VDC
100 VAC
110 VAC
200 VAC
230 VAC
24 VDC
24 VDC
100 VAC
110 VAC
200 VAC
230 VAC
24 VDC
100 VAC
110 VAC
200 VAC
230 VAC
24 VDC
100 VAC
110 VAC
200 VAC
230 VAC
24 VDC
Flat terminal
Grommet
Grommet
DIN terminal
Conduit terminal
Conduit
With surge
voltage
suppressor
With surge
voltage
suppressor
With surge
voltage
suppressor
With surge
voltage
suppressor
Aluminum
Resin
(With bracket)
A
B
C
D
E
F
G
H
J
K
L
M
N
5
8
10 (N.C. only)
5
8
10 (N.C. only)
10 (N.C. only)
5
8
10 (N.C. only)
5
8
10 (N.C. only)
1/4
3/8
1/2
ø10
ø12
Aluminum
Resin
(With bracket)
A
B
D
E
H
J
L
M
4
7
4
7
4
7
4
7
1/4
3/8
ø8
ø10
Aluminum
Resin
(With bracket)
N.O.
N.C.
Size 2
2
5
N.O.
N.C.
Size 3
3
6
N.O.
N.C.
Dimensions → Pages 56 to 59 (Single unit)
∗ One-touch fittings are attached
to the resin body type.
Fluid
0
Air
RoHS
RoHS
Direct Operated 2 Port Solenoid Valve
VX21/22/23 Series
Single UnitFor Air
®
Note) Refer to the table
on page 52 for
UL-compliant.
35
VX2
VXK
VXD
VXZ
VXS
VXB
VXE
VXP
VXR
VXH
VXF
VX3
VXA
VX2
A

Size
Orifice diameter
(mmø)
Note 1)
Model
Maximum operating
pressure differential
(MPa)
Note 3)
1.0
0.6
0.2
1.0
0.15
1.0
0.3
2
3
5
4
7
5
7
1
2
3
C [dm
3
/(s·bar)]
b
0.23
0.41
0.62
0.62
1.08
0.75
1.08
0.63
0.68
0.39
0.52
0.44
0.55
0.44
0.63
1.05
2.20
1.90
3.99
1.96
3.99
Cv
Flow rate characteristics
Note 2)
Normally Closed (N.C.)
VX2A0
VX2B0
VX2C0
Normally Open (N.O.)
Size
Orifice diameter
(mmø)
Note 1)
Model
Maximum operating
pressure differential
(MPa)
Note 3)
0.9
0.45
0.2
0.8
0.15
0.8
0.3
2
3
5
4
7
5
7
1
2
3
C [dm
3
/(s·bar)]
b
0.23
0.41
0.62
0.62
1.08
0.75
1.08
0.63
0.68
0.39
0.52
0.44
0.55
0.44
0.63
1.05
2.20
1.90
3.99
1.96
3.99
Cv
Flow rate characteristics
Note 2)
VX2D0
VX2E0
VX2F0
Common SUP type
2 (OUT)
1 (IN)
2 (OUT)
2 (OUT)
1 (IN)
2 (OUT)
1.0
Max. system pressure
(MPa)
Note 3)
1.0
When the valve is closed, flow is blocked from port 1 to port 2. However,
if the pressure in port 2 is higher than port 1, the valve will not be able to
block the fluid and it will flow from port 2 to port 1.
Model/Valve Specifications
VX21/22/23 Series
ManifoldFor Air
Symbol
N.C.
Common SUP type
N.O.
Symbol
Fluid and Ambient Temperature
Note) Dew point temperature: –10°C or less
Note 1) The orifice size is just as a reference guide. Check the flow rate characteristics (conversion Cv).
Note 2) The flow rate characteristics of this product have variations.
When the highly precise flow control is required according to the system to be used, select an orifice diameter 1.3 times larger than that shown
above and install a restrictor on the downstream side of the solenoid valve to make the adjustment.
Note 3) Refer to “Glossary of Terms” on page 65 for details on the maximum operating pressure differential and the maximum system pressure.
Ambient temperature (°C)
−20 to 60
Fluid temperature (°C)
−10
Note)
to 60
Valve Leakage Rate
Internal Leakage
Note 1) Leakage is the value at ambient temperature 20°C.
Note 2) For seal material/FKM, refer to “Other Options” on page 49 for the
selection.
Note 3) The amount of leakage is the value at a differential pressure of
0.01 MPa or more, and a temperature of 20°C.
External Leakage
NBR (FKM)
Seal material
Note 2)
Leakage rate
Note 1)
1 cm
3
/min or less
NBR (FKM)
Seal material
Note 2)
Leakage rate
Note 1)
1 cm
3
/min or less
Max. system pressure
(MPa)
Note 3)
36
B