Model/Valve Speci fications N.C. Port size Size Orifice diameter (mmø) Note 1) Model Maximum operating pressure differential (MPa) Note 4) 1.0 0.6 0.2 1.0 0.15 1.0 0.3 0.1 0.1 2 3 5 4 7 5 8 10 10 1/8, 1/4 1/4, 3/8 1/4, 3…

100%1 / 56
VX21/22/23 Series
Selection Steps
Item
Select the fluid.
Select electrical
specification.
Selection item
Symbol
Air
Water
Oil
Medium
vacuum
0
2
3
4
5
Symbol
3
A
Symbol
A
Page
Page 33, 34
Page 42
Page 44
Page 38
Page 46
VX2 3 0 A A
VX2 3 A A0
Size
Body material
Port size
Orifice diameter
Size 3
Aluminum
1/8
2
VX2 3 0 A A
Voltage
Electrical entry
Grommet
24 VDC
Steam
∗
Can be used with heated water.
Select from “Flow
rate — Pressure.”
Body material
Port size
Orifice diameter
Item
Selection item
Item
Selection item
Select the fluid.
Select electrical specification.
For special options, refer to pages 49 to 51.
Select “Body material”, “Port size” and “Orifice diameter” from “Flow rate — Pressure” of each fluid.
Step 1
Step 2
Step 3
Step 4
Selection Steps
q
e
r
r
e
w
w
q
32
Model/Valve Specifications
N.C.
Port size
Size
Orifice diameter
(mmø)
Note 1)
Model
Maximum operating
pressure differential
(MPa)
Note 4)
1.0
0.6
0.2
1.0
0.15
1.0
0.3
0.1
0.1
2
3
5
4
7
5
8
10
10
1/8, 1/4
1/4, 3/8
1/4, 3/8
1/2
1
2
3
C [dm
3
/(s·bar)]
b
0.23
0.41
0.62
0.62
1.08
0.75
1.58
2.21
2.21
1.0
0.63
0.68
0.39
0.52
0.44
0.55
0.33
0.64
0.39
0.63
1.05
2.20
1.90
3.99
1.96
5.67
5.74
8.42
Cv
Flow rate characteristics
Note 2)
AIuminum Body Type
VX210
VX220
VX230
VX210
VX220
VX230
Port sizeSize
Orifice diameter
(mmø)
Note 1)
Model
Maximum operating
pressure differential
(MPa)
Note 4)
1.0
0.6
0.2
1.0
0.6
0.2
1.0
0.15
1.0
0.15
1.0
0.3
0.1
1.0
0.3
0.1
0.82
1.25
1.45
0.82
1.81
2.11
1.69
3.14
1.68
3.54
2.50
2.77
5.69
2.50
2.56
5.69
2
3
5
2
3
5
4
7
4
7
5
8
10
5
8
10
ø6
ø8
ø8
ø10
ø10
ø12
1
2
3
C [dm
3
/(s·bar)]
b Cv
Flow rate characteristics
Note 2)
Resin Body Type (Built-in One-touch Fittings)
Max. system pressure
(MPa)
Note 4)
Max. system pressure
(MPa)
Note 4)
0.44
0.34
0.43
0.44
0.40
0.32
0.40
0.34
0.49
0.36
0.44
0.82
0.46
0.44
0.88
0.64
0.23
0.35
0.40
0.23
0.41
0.56
0.47
0.84
0.50
0.90
0.70
1.22
1.54
0.70
1.38
1.76
1.0
220
220
220
340
340
450
450
450
470
220
220
220
220
220
220
340
340
340
340
460
460
460
460
460
460
21
When the valve is closed, flow is blocked from port 1 to port 2. However, if the pressure in port 2 is
higher than port 1, the valve will not be able to block the fluid and it will flow from port 2 to port 1.
Direct Operated 2 Port Solenoid Valve
VX21/22/23 Series
For Air Single Unit
Symbol
Note 1) The orifice size is just as a reference guide. Check the flow rate characteristics (conversion Cv).
Note 2) The flow rate characteristics of this product have variations.
When the highly precise flow control is required according to the system to be used, select an orifice diameter 1.3 times larger than that shown
above and install a restrictor on the downstream side of the solenoid valve to make the adjustment.
Note 3) Weight of grommet type. Add 10 g for conduit type, 30 g for DIN terminal type, 60 g for conduit terminal type respectively.
Note 4) Refer to “Glossary of Terms” on page 65 for details on the maximum operating pressure differential and the maximum system pressure.
Fluid and Ambient Temperature
Note) Dew point temperature: −10°C or less
−20 to 60
Ambient temperature (°C)Fluid temperature (°C)
−10
Note)
to 60
Valve Leakage Rate
Internal Leakage
Note 1) Leakage is the value at ambient temperature 20°C.
Note 2) For seal material/FKM, refer to “Other Options” on page 49 for the
selection.
Note 3) The amount of leakage is the value at a differential pressure of
0.01 MPa or more, and a temperature of 20°C.
External Leakage
NBR (FKM)
Seal material
Note 2)
Leakage rate (Air)
Note 1)
1 cm
3
/min or less (AIuminum body type)
15 cm
3
/min or less (Resin body type)
NBR (FKM)
Seal material
Note 2)
Leakage rate (Air)
Note 1)
1 cm
3
/min or less (AIuminum body type)
15 cm
3
/min or less (Resin body type)
Weight
(g)
Note 3)
Weight
(g)
Note 3)
33
VX2
VXK
VXD
VXZ
VXS
VXB
VXE
VXP
VXR
VXH
VXF
VX3
VXA
VX2
B
Port sizeSize
Orifice diameter
(mmø)
Note 1)
Model
Maximum operating
pressure differential
(MPa)
Note 4)
0.9
0.45
0.2
0.8
0.15
0.8
0.3
2
3
5
4
7
5
8
1/8, 1/4
1/4, 3/8
1/4, 3/8
1
2
3
C [dm
3
/(s·bar)]
b
0.23
0.41
0.62
0.62
1.08
0.75
1.58
240
240
240
370
370
490
490
0.63
0.68
0.39
0.52
0.44
0.55
0.33
0.63
1.05
2.20
1.90
3.99
1.96
5.67
Cv
Flow rate characteristics
Note 2)
Note 3)
Note 3)
VX240
VX250
VX260
VX240
VX250
VX260
Port sizeSize
Orifice diameter
(mmø)
Note 1)
Model
Maximum operating
pressure differential
(MPa)
Note 4)
0.9
0.45
0.2
0.9
0.45
0.2
0.8
0.15
0.8
0.15
0.8
0.3
0.8
0.3
0.82
1.25
1.45
0.82
1.81
2.11
1.69
3.14
1.68
3.54
2.50
2.77
2.50
2.56
2
3
5
2
3
5
4
7
4
7
5
8
5
8
ø6
ø8
ø8
ø10
ø10
ø12
1
2
3
C [dm
3
/(s·bar)]
b Cv
Flow rate characteristics
Note 2)
0.44
0.34
0.43
0.44
0.40
0.32
0.40
0.34
0.49
0.36
0.44
0.82
0.42
0.88
0.23
0.35
0.40
0.23
0.41
0.56
0.47
0.84
0.50
0.90
0.70
1.22
0.70
1.38
240
240
240
240
240
240
370
370
370
370
500
500
500
500
21
1.0
1.0
Note 1) The orifice size is just as a reference guide. Check the flow rate characteristics (conversion Cv).
Note 2) The flow rate characteristics of this product have variations.
When the highly precise flow control is required according to the system to be used, select an orifice diameter 1.3 times larger than that shown
above and install a restrictor on the downstream side of the solenoid valve to make the adjustment.
Note 3) Weight of grommet type. Add 10 g for conduit type, 30 g for DIN terminal type, 60 g for conduit terminal type respectively.
Note 4) Refer to “Glossary of Terms” on page 65 for details on the maximum operating pressure differential and the maximum system pressure.
AIuminum Body Type
Resin Body Type (Built-in One-touch Fittings)
When the valve is closed, flow is blocked from port 1 to port 2. However, if the pressure in port 2 is
higher than port 1, the valve will not be able to block the fluid and it will flow from port 2 to port 1.
For Air Single Unit
VX21/22/23
Series
Model/Valve Specifications
Symbol
N.O.
Fluid and Ambient Temperature
Note) Dew point temperature: −10°C or less
−20 to 60
Ambient temperature (°C)Fluid temperature (°C)
−10
Note)
to 60
Internal Leakage
Note 1) Leakage is the value at ambient temperature 20°C.
Note 2) For seal material/FKM, refer to “Other Options” on page 49 for the
selection.
Note 3) The amount of leakage is the value at a differential pressure of
0.01 MPa or more, and a temperature of 20°C.
External Leakage
NBR (FKM)
Seal material
Note 2)
Leakage rate (Air)
Note 1)
1 cm
3
/min or less (AIuminum body type)
15 cm
3
/min or less (Resin body type)
NBR (FKM)
Seal material
Note 2)
Leakage rate (Air)
Note 1)
1 cm
3
/min or less (AIuminum body type)
15 cm
3
/min or less (Resin body type)
Max. system pressure
(MPa)
Note 4)
Max. system pressure
(MPa)
Note 4)
Weight
(g)
Valve Leakage Rate
Weight
(g)
34