6-9-p0027-0080-vx21_en.pdf - 第12页
Normally Closed (N.C.) Port size Size Orifice diameter (mmø) Note 1) Model Operating pressure range 2 3 5 4 7 5 8 10 10 1/8, 1/4 1/4, 3/8 1/4, 3/8 1/2 1 2 3 C [dm 3 /(s·bar)] b 0.23 0.41 0.62 0.62 1.08 0.75 1.58 2.21 2.2…

VX2
0A A A
Common Specifications
NBR
Class B
Seal material
Coil insulation type
Coil size/Valve type
Body material/Orifice diameter
Voltage/Electrical entry
Symbol
Size
Size 1
Valve type
Symbol
A
B
C
A
B
A
B
A
D
N.C.
N.O.
Body
material
Orifice diameter
2
3
5
4
7
5
7
Symbol
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
Y
Z
Electrical entry
Other voltages
Voltage
24 VDC
100 VAC
110 VAC
200 VAC
230 VAC
24 VDC
24 VDC
100 VAC
110 VAC
200 VAC
230 VAC
24 VDC
100 VAC
110 VAC
200 VAC
230 VAC
24 VDC
100 VAC
110 VAC
200 VAC
230 VAC
24 VDC
Flat terminal
Grommet
Grommet
DIN terminal
Conduit terminal
Conduit
With surge
voltage
suppressor
With surge
voltage
suppressor
With surge
voltage
suppressor
With surge
voltage
suppressor
Size 2
B
E
N.C.
N.O.
Size 3
C
F
N.C.
N.O.
Resin
Resin
Resin
Dimensions → Page 63
VVX2
01 A 02
Coil size
Base material/Port size/Base type
Symbol
Size
Size 1
Size 2
Size 3
Symbol
A
B
1/8
1/4
1
2
3
Base
material
Base
type
Individual
port size
Aluminum
Common
SUP
Symbol
Nil
A
B
D
E
Z
Rc
G
∗
1
NPT
G
∗
1
NPT
Rc
—
—
—
Oil-free
Special
thread
Stations
Symbol
02
03
04
05
06
07
08
09
10
Stations
2 stations
3 stations
4 stations
5 stations
6 stations
7 stations
8 stations
9 stations
10 stations
Manifold Base/How to Order
Blanking Plate Assembly Part No.
How to Order Manifold Assembly (Example)
N
F
NBR
FKM
Seal material
For size 1
VVX021S 4A
For size 2
VVX022S 4A
For size 3
VVX023S 4A
When mounting a blanking plate
assembly, if the solenoid valve for
the manifold is ozone resistant,
(Seal material: FKM), please se-
lect FKM.
For special options,
refer to pages 49 to 51.
24 VAC
48 VAC
220 VAC
240 VAC
12 VDC
Special voltage
DIN terminal with light
Conduit terminal with light
Without DIN connector
Seal material: EPDM
Low concentration ozone resistant (Seal material: FKM)
Oil-free
Special electrical entry direction
Common port size: 3/8
(IN port)
N
N
N
Fluid
0
Air
Fluid
0
Air
How to Order (Solenoid Valve for Manifold)
Mounting orientation exists
when mounting valves onto
manifold base. Refer to page
76 for details.
Caution
∗1 For connection,
prepare a fitting
compliant with ISO
16030 and JIS B 8674.
Stations
D side
5 x Rc1/4
(Individual port)
<Example>
5
4
321
Stations
Enter the product’s part number in order, counting the 1st station from the D side
(left in the manifold arrangement, when viewing the individual port in front).
Enter the valve and blanking plate to be mounted under the manifold
base part number.
U side
D side
VVX210B05
………...
1
∗VX2A0AA ………….4
∗VVX021S-4A-N ……1
“∗” is the symbol for mounting.
Add an “∗” in front of the part numbers for solenoid
valves etc. to be mounted.
37
RoHS
Direct Operated 2 Port Solenoid Valve
VX21/22/23 Series
ManifoldFor Air
VX2
VXK
VXD
VXZ
VXS
VXB
VXE
VXP
VXR
VXH
VXF
VX3
VXA
VX2
B

Normally Closed (N.C.)
Port size
Size
Orifice diameter
(mmø)
Note 1)
Model
Operating pressure range
2
3
5
4
7
5
8
10
10
1/8, 1/4
1/4, 3/8
1/4, 3/8
1/2
1
2
3
C [dm
3
/(s·bar)] b
0.23
0.41
0.62
0.62
1.08
0.75
1.58
2.21
2.21
0.63
0.68
0.39
0.52
0.44
0.55
0.33
0.64
0.39
0.63
1.05
2.20
1.90
3.99
1.96
5.67
5.74
8.42
Cv
Flow rate characteristics
Note 2)
VX214
VX224
VX234
300
300
300
460
460
580
580
580
630
0 to 1.0
0 to 0.6
0 to 0.2
0 to 1.0
0 to 0.15
0 to 1.0
0 to 0.3
0 to 0.1
0 to 0.1
Normally Open (N.O.)
Note 1) The orifice size is just as a reference guide. Check the flow rate characteristics (conversion Cv).
Note 2) The flow rate characteristics of this product have variations.
When the highly precise flow control is required according to the system to be used, select an orifice diameter 1.3 times larger than that shown
above and install a restrictor on the downstream side of the solenoid valve to make the adjustment.
Note 3) Weight of grommet type. Add 10 g for conduit type, 30 g for DIN terminal type, 60 g for conduit terminal type respectively.
Port size
Size
Orifice diameter
(mmø)
Note 1)
Model
2
3
5
4
7
5
8
1/8, 1/4
1/4, 3/8
1/4, 3/8
1
2
3
C [dm
3
/(s·bar)]
b
0.23
0.41
0.62
0.62
1.08
0.75
1.58
0.63
0.68
0.39
0.52
0.44
0.55
0.33
0.63
1.05
2.20
1.90
3.99
1.96
5.67
Cv
Flow rate characteristics
Note 2)
VX244
VX254
VX264
320
320
320
490
490
620
620
0 to 0.9
0 to 0.45
0 to 0.2
0 to 0.8
0 to 0.15
0 to 0.8
0 to 0.3
21 21
2121
1.0
0.1 to atmospheric
pressure
0.1 to atmospheric
pressure
Max. system
pressure
(MPa)
1.0
Max. system
pressure
(MPa)
∗ This valve can also be used with air.
(Refer to the valve specifications for air.)
When the valve is closed, flow is blocked from port 1 to port 2.
However, if the pressure in port 2 is higher than port 1, the valve
will not be able to block the fluid and it will flow from port 2 to port 1.
VX21/22/23 Series
Single Unit
For Medium Vacuum
(0.1 Pa·abs or more)
Model/Valve Specifications
Symbol (Application example)Symbol (Application example)
N.C. N.O.
w Used with
pressure
q Used with
vacuum
w Used with
pressure
q Used with
vacuum
Weight
(g)
Note 3)
Weight
(g)
Note 3)
When the valve is closed, flow is blocked from port 1 to port 2.
However, if the pressure in port 2 is higher than port 1, the valve
will not be able to block the fluid and it will flow from port 2 to port 1.
Fluid and Ambient Temperature Valve Leakage Rate
Ambient temperature (°C)
−20 to 60
Fluid temperature (°C)
1 to 60
Note)
FKM
Seal material Leakage rate
Note)
10
−6
Pa·m
3
/sec or less
FKM
Seal material Leakage rate
Note)
10
−6
Pa·m
3
/sec or less
Note) With no freezing
Internal Leakage
External Leakage
Note) Leakage (10
−6
Pa·m
3
/sec) is the value at differential pressure 0.1
MPa and ambient temperature 20°C.
q
Used with vacuum (Pa·abs)
w
Used with pressure (MPa·G)
Operating pressure range
q
Used with vacuum (Pa·abs)
w
Used with pressure (MPa·G)
38
B

VX2
41 A A
Common Specifications
FKM
Class B
Rc
Seal material
Coil insulation type
Thread type
Oil-free
Non-leak
For special options, refer to pages 49 to 51.
Coil size/Valve type
Body material/Port size/Orifice diameter
Voltage/Electrical entry
Symbol
Size
Size 1
Valve type
Symbol
A
B
C
D
E
F
H
J
K
L
M
N
1
4
Body
material
Orifice
diameter
2
3
5
2
3
5
2
3
5
2
3
5
1/8
1/4
1/8
1/4
Port size
Symbol
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
Y
Z
Electrical entry
Other voltages
Voltage
24 VDC
100 VAC
110 VAC
200 VAC
230 VAC
24 VDC
24 VDC
100 VAC
110 VAC
200 VAC
230 VAC
24 VDC
100 VAC
110 VAC
200 VAC
230 VAC
24 VDC
100 VAC
110 VAC
200 VAC
230 VAC
24 VDC
Flat terminal
Grommet
Grommet
DIN terminal
Conduit terminal
Conduit
With surge
voltage
suppressor
With surge
voltage
suppressor
With surge
voltage
suppressor
With surge
voltage
suppressor
C37
A
B
D
E
H
J
L
M
4
7
4
7
4
7
4
7
1/4
3/8
1/4
3/8
A
B
C
D
E
F
G
H
J
K
L
M
N
P
5
8
10 (N.C. only)
5
8
10 (N.C. only)
10 (N.C. only)
5
8
10 (N.C. only)
5
8
10 (N.C. only)
10 (N.C. only)
1/4
3/8
1/2
1/4
3/8
1/2
N.O.
N.C.
Size 2
2
5
N.O.
N.C.
Size 3
3
6
N.O.
N.C.
Dimensions→ Pages 60, 61 (Single unit)
24 VAC
48 VAC
220 VAC
240 VAC
12 VDC
Special voltage
DIN terminal with light
Conduit terminal with light
Without DIN connector
Seal material: EPDM
G thread
NPT thread
With bracket
Mounting holes on the bottom side of the body
Special electrical entry direction
Fluid
4
Medium vacuum
Stainless
steel
C37
Stainless
steel
C37
Stainless
steel
How to Order (Single Unit)
39
Direct Operated 2 Port Solenoid Valve
VX21/22/23 Series
Single UnitFor Medium Vacuum
RoHS
®
Note) Refer to the table on
page 53-1 for
UL-compliant products.
VX2
VXK
VXD
VXZ
VXS
VXB
VXE
VXP
VXR
VXH
VXF
VX3
VXA
VX2
B