Electrical Connections
Caution
Grommet
Class B coil: AWG20 Insulator O.D. 2.6 mm
Class H coil: AWG18 Insulator O.D. 2.1 mm
Caution
Operating Environment
Warning
1. Be sure to have appropriate protective measures in
place when installed in environments where there is
the constant presence of water, such as water spray,
condensation, high humidity, etc. This product has
an IP65 protective construction; however, when
used in the above-mentioned environments, liquid
may find its way inside the enclosure through micro-
scopic gaps, possibly resulting in the burning out,
short-circuiting, or ignition of coils.
2. Do not use in an atmosphere having corrosive gases,
chemicals, sea water, or where there is direct contact
with any of these.
3. Do not use in explosive atmospheres.
4. Do not use in locations subject to vibration or impact.
5. Do not use in locations where radiated heat will be
received from nearby heat sources.
6. Employ suitable protective in locations where there
is contact with oil or welding spatter, etc.
Maintenance
Warning
1. Filters and strainers
1) Be careful regarding clogging of filters and strainers.
2) Replace filter elements after one year of use, or earlier if the
pressure drop reaches 0.1 MPa.
3) Clean strainers when the pressure drop reaches 0.1 MPa.
2. Lubrication
When using after lubricating, never forget to lubricate continuously.
3. Storage
In case of long term storage after use, thoroughly remove all
moisture to prevent rust and deterioration of rubber materials etc.
4. Exhaust the drainage from an air filter periodically.
1. Removing the product
The valve will reach a high temperature when used with high
temperature fluids. Confirm that the valve temperature has
dropped sufficiently before performing work. If touched inadver-
tently, there is a danger of being burned.
1) Shut off the fluid supply and release the fluid pressure in the
system.
2) Shut off the power supply.
3) Dismount the product.
2. Low frequency operation
Switch valves at least once every 30 days to prevent malfunc-
tion. Also, in order to use it under the optimum state, conduct a
regular inspection once a half year.
Operating Precautions
Warning
1.
If there is a possibility of reverse pressure being applied
to the valve, take countermeasures such as mounting a
check valve on the downstream side of the valve.
2. When problems are caused by a water hammer, in-
stall water hammer relief equipment (accumulator
etc.), or use an SMC water hammer relief valve (VXR
series).
VX21/22/23 Series
Specific Product Precautions 6
Be sure to read this before handling the products.
Refer to back page 50 for Safety Instructions and pages 17 to 19 for 2 Port Solenoid
Valve for Fluid Control Precautions.
q
w
DIN terminal
Disassembly
1. After loosening the binding head screw with flange, then if the
housing is pulled in the direction of the arrow, the connector will
be removed from the solenoid valve.
2. Pull out the binding head screw with flange from the housing.
3. There is a cutout on the bottom of the terminal block. Insert a
small flat head screwdriver, etc. into this cutout, and remove the
terminal block from the housing. (See figure below.)
4.
Remove the ground nut, and pull out the washer and the rubber seal.
Wiring
1. Pass the cable through the ground nut, washer and rubber seal
in this order, and insert these parts into the housing.
2. Loosen the binding head screw of the terminal block, then insert
the core wire or the crimped terminal of the lead wire into the
terminal, and securely fix it with the binding head screw. The
binding head screw of the terminal block is M3.
Note 1)
Tighten the screw to a torque of between 0.5 and 0.6 N·m.
Note 2) Cable O.D.: ø6 to ø12 mm
Note 3) For an outside cable diameter of ø9 to 12 mm, remove
the internal parts of the rubber seal before using.
Assembly
1. Pass the cable through the ground nut, washer, rubber seal and
the housing in this order, and connect to the terminal block.
Then, set the terminal block inside the housing. (Push in the
terminal block until it snaps into position.)
2. Insert the rubber seal and the washer in this order into the cable
entry of the housing, and then tighten the ground nut securely.
3.
Insert the gasket between the bottom part of the terminal block and
the plug attached to the equipment, and then insert the binding
head screw with flange from the top of the housing, and tighten it.
Note 1)
Tighten the screw to a torque of between 0.5 and 0.6 N·m.
Note 2)
The orientation of the connector can be changed in steps
of 90° by changing the method of assembling the housing
and the terminal block.
Rated
voltage
DC
100 VAC
200 VAC
Other AC
q
Black
Blue
Red
Gray
w
Red
Blue
Red
Gray
Lead wire color
∗ There is no polarity.
Housing
Crimped terminal
Applicable crimped terminal: JIS C2805 R1.25-3
Ground nut
Washer
Cable
Rubber seal
Binding head screw with flange
Light (When
equipped
with a light)
∗
1
Terminal
block
∗1
The position is fixed regardless of the electrical entry direction.
Binding
head screw
78
E
A
A
View A-A
(Internal connection diagram)
+ Mark
– Mark
Round head
combination screw
M3 Tightening torque
0.5 to 0.6 N·m
Round head combination screw
M3
Tightening torque 0.5 to 0.6 N·m
Terminal cover
Conduit terminal
G1/2
Tightening torque
0.5 to 0.6 N·m
Make connections according to the marks shown below.
• Use the tightening torques below for each section.
• Properly seal the terminal connection (G1/2) with the special
wiring conduit etc.
Electrical Connections
CautionCaution
VX21/22/23 Series
Specific Product Precautions 7
Be sure to read this before handling the products.
Refer to back page 50 for Safety Instructions and pages 17 to 19 for 2 Port Solenoid
Valve for Fluid Control Precautions.
Conduit terminal
Disassembly
1. Loosen the mounting screw, and remove the terminal cover
from the conduit terminal.
Wiring
1. Insert the cable into the conduit terminal.
2. Loosen the screw with UP terminal of the conduit terminal, then
insert the core wire or the crimped terminal of the lead wire into
the terminal, and securely fix it with the screw with UP terminal.
Note 1)
Tighten the screw to a torque of between 0.5 and 0.6 N·m.
2
3
+
—
1
2: –
(+)
Grounding
1: +
(–)
Internal connections are as shown below. Make connections to
the power supply accordingly.
∗ There is no polarity.
Terminal no.
DIN terminal
1
+(–)
2
–(+)
1
+
2
−
Assembly
1. Insert the gasket into the conduit terminal, and then clamp the
terminal cover with the mounting screw.
Note 1)
Tighten the screw to a torque of between 0.5 and 0.6 N·m.
Note 2) When changing the orientation of the conduit terminal,
carry out the following procedure.
1. Apply a tool (monkey wrench, spanner, etc.) to the width
across flats of the conduit terminal, and turn the terminal in
the counterclockwise direction.
2. Loosen the lock nut.
3. Turn the conduit terminal in the clamping direction (clockwise
direction) to about 15° ahead of the desired position.
4. Turn the lock nut by hand to the coil side until it is lightly
tightened.
5. Apply a tool to the width across flats of the conduit terminal,
and turn it to the desired position (through an angle of about
15°) so as to clamp the conduit terminal.
Note) When changing the orientation by applying additional
tightening force to the conduit terminal from the factory-
set position, turn no more than one half a turn.
Light (When equipped with a light)
SMC
Conduit terminal
Lock nut
Grounding
Cable connector
Crimped terminal
Applicable crimped terminal:
JIS C2805 R1.25-3
Screw with
UP terminal
Gasket
Mounting screw
Terminal cover
Conduit terminal
DIN (EN175301-803) Terminal
This DIN terminal corresponds to the Form A DIN connector with
an 18 mm terminal pitch, which complies with EN175301-803B.
2
1
3
18
9
79
VX2
VXK
VXD
VXZ
VXS
VXB
VXE
VXP
VXR
VXH
VXF
VX3
VXA
VX2
C
Caution
Electrical Circuits
Caution
Electrical Connections
Without electrical option
DIN terminal, Conduit terminalGrommet, DIN terminal,
Conduit terminal, Conduit
[AC circuit]
DIN terminal, Conduit terminal
With light/surge voltage suppressor
With light/surge voltage suppressor
With surge voltage suppressor
Grommet, DIN terminal,
Conduit terminal, Conduit
Without electrical option
Grommet, Flat terminal
[DC circuit]
∗ For AC (Class B), the standard product is equipped with surge voltage
suppressor.
One-touch Fitting
Caution
For information on handling One-touch fittings and on
appropriate tubing, refer to page 77 and the Fittings &
Tubing section of the “Handling Precautions for SMC
Products” on the SMC website.
VX21/22/23 Series
Specific Product Precautions 8
Be sure to read this before handling the products.
Refer to back page 50 for Safety Instructions and pages 17 to 19 for 2 Port Solenoid
Valve for Fluid Control Precautions.
Class B coil: AWG20 Insulator O.D. 2.5 mm
Class H coil: AWG18 Insulator O.D. 2.1 mm
Lead wire
q
Seal
Wiring conduit
(Bore size G1/2 Tightening torque 0.5 to 0.6 N·m)
w
Conduit
When used as an IP65 equivalent, use seal to install the wiring
conduit. Also, use the tightening torque below for the conduit.
∗ There is no polarity.
Note) Please order separately.
Rated voltage
DC
100 VAC
200 VAC
Other AC
q
Black
Blue
Red
Gray
w
Red
Blue
Red
Gray
Lead wire color
Description
Seal VCW20-15-6
Part no.
Light
Varistor
Varistor
Varistor
Rectifier
element
2
1
2
1
Rectifier
element
Varistor
SOL.
SOL.
2 (–, +)
1 (+, –)
SOL.
Light
2 (–, +)
1 (+, –)
2 (–, +)
1 (+, –)
SOL.
SOL.
80
B