00196286-0102_RI_Dig-Druckluftregelventil_DE EN.pdf - 第20页
Retrofit instructions Digital pressure regulation valve and new air filter Twinhead 08/2008 Edition 20 2.3 Required p arts 1 Retrofit kit s (preassembled) Item no: 03071759-01 1 Air filter , complete Item no: 03051420-01…
Retrofit instructions Digital pressure regulation valve and new air filter Twinhead
08/2008 Edition
19
2 Retrofit instructions
Digital Pressure regulation valve and
new air filter Twinhead
SIPLACE HF-series / X-series / D3
2.1 Reason for retrofit
To further improve the quality and user-friendliness of the Twinhead placement head, the "Digital
pressure regulation valve, Twinhead 03058802-01" with a new "Air filter unit comp. 03051420-01"
has been introduced. 2
This replaces the old analog "Vacuum regulation system 0
3002566S01“ and the old "Air filter unit
comp. 03013061S01". 2
In the past, one of the Twinhead modules had to be
removed in order to perform maintenance to
the air filter. After the upgrade, the air filters at both modules are accessible without removal. 2
2.2 Necessary tools
– Set of Allen keys
– Set of screwdrivers
2

Retrofit instructions Digital pressure regulation valve and new air filter Twinhead
08/2008 Edition
20
2.3 Required parts
1
Retrofit kits (preassembled) Item no: 03071759-01
1 Air filter, complete
Item no: 03051420-01
1 Silicon hose 4.5x2.5x60
Item no: 03053642-01
1 Silicon hose 4.5x2.5x96
Item no: 03046416-01
1 Dig. pressure reg. valve Twinhead
Item no: 03058802-01
1 Mounting bracket
Item no: 03041233-02
1 Precision tube 4x0.5x56
Item no: 03052632-01
2 Clamp d=5 H2P
Item no: 03052551-01
2 DIN EN ISO 7380-M4 x 6-A2
Item no: 00319283-01
2 DIN912-M3 x 6-A2-70
Item no: 00201463-01
1
Retrofit instructions Digital pressure regulation valve and
new air filter Twinhead SIPLACE X-series
Item no: 00196286-xx
Optional (not included in the retrofit kit)
1
Main head board for P+P head
Item no: 00352833-09
2
2
2
2
The board does not form part of the retrofit kit and must be ordered separately if required.
If you want to replace the main head board, please note th
e instructions in chapter 2.5 "Prerequi-
sites for the conduct of this retrofit"
, the note at "Final works" and the corresponding Service Man-
ual. 2

Retrofit instructions Digital pressure regulation valve and new air filter Twinhead
08/2008 Edition
21
2.4 Safety instructions
WARNING
The safety instructions from the “Oper
ational safety” chapter of the user manual and servicing in-
structions take precedence over these instructions. 2
The SIPLACE placement machines are supplied with main power voltage.
Consequently parts of these systems carry dangerous vo
ltages! This voltage is present at certain
modules inside the machine base, even when the machine is switched off at the main power
switch.
Incorrect handling of the placement machine or touching live parts of the machine can result in
death
or severe injury, and considerable damage to equipment.
BEFORE starting any work, shut down the operating system correct
ly, then switch the machine
OFF at the main power switch and disconnect from the main power supply. In addition, the com-
pressed air supply must be switched off at the compressed air unit's main valve
in the machine
base and vented by actuating the needle valve on the compressed air unit.
There is DANGER for heart pacemaker wearers in the
vicinity of the linear motors, as described
in detail in the "Special safety instructions for working in the vicinity of strong magnetic fields"
section of the user manual and service manual.
Always follow the accident prevention regulations, DIN or
other standards and special safety
rules applicable in your country.
Pay attention to the information concerning residual volt
ages in the Operational Safety chapter.
Follow the ESD regulations as described in the oper
ational safety section of the operating
instructions.
During the retrofit, always secure the machine to prevent access by other people and to prevent
it being
switched on again as described in the "Lock out and tag out procedure" in the user man-
ual.
Working with the SITEST program further increases the risk of accident.
The SITEST program must only be used by autho
rized and trained personnel.
2
2
2.4.1 Definitions
2
Please note 2
2
2
2