Retrofit instructions Digital pressure regulation valve and new air filter Twinhead 08/2008 Edition 30 : Screw the buffer back onto the retur n unit shaft and fix the unit. . 2 The lower side of the buf fer must be flus …

Retrofit instructions Digital pressure regulation valve and new air filter Twinhead
08/2008 Edition
29
: Fasten the digital pressure regulating valve using the two securing screws (see left picture at
page 50).
Securing screws 2
2
2
: Rotate the return unit to its starting position and fix it in position.
Insert the hose on the precision tube.
Insert hose 2
Return unit fixing 2
2
2
2
2

Retrofit instructions Digital pressure regulation valve and new air filter Twinhead
08/2008 Edition
30
: Screw the buffer back onto the return unit shaft and fix the unit..
2
The lower side of the buffer must be flush with the screw. (Check with feeler gauge). 2
Feeler
Screw 2
Buffer 2
2
2
2
2

Retrofit instructions Digital pressure regulation valve and new air filter Twinhead
08/2008 Edition
31
2.8 Final works
After installing the head, perform the following concluding work in SITEST: 2
: Check the dat
a in the “ Head exchange” menu.
: Perform zero calibration for pressure regulator.
: Calibrate the pl
acement head.
: Calibrate the offset camera-nozzle.
2
If the main head board was replaced during the upgrade (FS 09), then the data from the machine
data must be transferred to the "Head EPROM". 2
If EM: 17508 „No head type entered in head EPROM" appears then you must enter the appropri-
ate head type in SITEST under "Machine configuration". 2
2.9 Replacement of the air filter insert
: Install the air filter insert.
2
When installing, please make sure to insert the replacement filter with brass colored front end in
the lower of the two apertures. 2
2