36. Copy the renewed Proper data from floppy to F4G/FujiCam and add the center offset value of XLS. 37. Check the 3 σ value. 38. Transmit the Proper data to the machine and reboot. 39. Repeat procedures 2 ~ 38. Note: If …

18. Press [AUTO] to transmit the program to the PMC.
19. Press [SET] → [PROPER] → ID No. → [PM] → select the module →
[FINISH] → [Part Camera] → [CALIB CNTR] → [In turn meas] →
[EXECUTE] → Enter a starting PM No. and final PM No. → START.
20. Press [SET] → [PROPER] → ID code → [PM → [SET] → [PARTS
CAMERA] → [T MARK] → [MEASURE] → START.
21. Repeat a few times to stabilize the value.
22. Load one board on the machine and execute PAM production.
23. When Manipulator sets the board on the pallet in the IN-Transfer
Loader, press [CLEAR OFF] and produce only one board.
24. Transmit the Proper data to F4G/FujiCam. Copy the Proper data to a
floppy disk.
25. Set the completed board in the DT451.
26. Boot the software, “DT-651 Placement Position Auto-calibration system”.
27. Press [F1] to zero set.
28. Press [F1] to select the program PAM_ALL.PGO.
29. Press START to measure the placement.
30. Select [Renew Proper].
31. Insert the floppy disk and select the Proper from the floppy disk.
32. Press [OK] to rewrite the Proper data.
33. Press [FILE] to save the measured data to the floppy.
34. Insert the floppy disk to the PC.
35. Copy the sequence on the measured data to the QP132_1Cpk.xls for the
offset calculation.
Note: DXC, DXY, nozzle center offset value, will be displayed on the right side of the chart.
The adjacent chart is the current arrangement.
Chapter 11 11.1 PAM
Edition 1.1 11-3 QP-132 Level 3 Tutorial

36. Copy the renewed Proper data from floppy to F4G/FujiCam and add the
center offset value of XLS.
37. Check the 3σ value.
38. Transmit the Proper data to the machine and reboot.
39. Repeat procedures 2 ~ 38.
Note: If a particular nozzle has poor accuracy, other causes may need to be investigated.
40. Repeat the procedure until:
CP: more than 1.7
CPK: more than 1.4
AVE: less than ± 20 µm
3σ: less than 100
Note: If the accuracy does not satisfy these conditions, contact FUJI.
ZC Automatic measurement for rotation center
-200
-100
0
100
200
-200 -100 0 100 200
0¡
90¡
180¡
270¡
ZC Rotate center with offset
-200
-100
0
100
200
-200 -100 0 100 200
0¡
90¡
180¡
270¡
QP132T11002
Chapter 11 11.1 PAM
Edition 1.1 11-4 QP-132 Level 3 Tutorial

11.1.2 Nozzle E and F
1. Enter zero for MQ3ANEOX [PM1] Nozzle _ E Offset X,Y.
2. Enter the value of MQ3ANDOX [PM1] Nozzle _ D Offset X,Y to
MQ3ANFOX [PM1] Nozzle _ F Offset X,Y.
3. Enter the value of MQ3ACOAX [PM1] Center offset A_X to MQ3ACOEX
[PM1] Center Offset E_X.
4. Enter the value of MQ3ACOAY [PM1] Center offset A_Y to MQ3ACOEY
[PM1] Center Offset E_Y.
5. Enter the value of MQ3ACODX [PM1] Center offset D_X to MQ3ACOEX
[PM1] Center Offset F_X.
6. Enter the value of MQ3ACODY [PM1] Center offset D_Y to MQ3ACOEY
[PM1] Center Offset F_Y.
7. Use program PAM_EF. PGO.
8. Repeat procedures 3 ~ 7 and 12 ~ 34 of Nozzle A, B, C and D.
Note: It is not necessary to measure the T-Mark.
9. Copy the sequence on the measured data to the QP132_1Cpk.xls for the
offset calculation.
10. Repeat the procedure 36 ~ 40 of Nozzle A, B, C and D.
Chapter 11 11.1 PAM
Edition 1.1 11-5 QP-132 Level 3 Tutorial