3-34 3 Periodic maintenance items 4.3 Operation check of head blow valve and cleaning blow valve Check the oper ation of the head unit valv e (solenoid valv e). T he head unit valve includes the follo wing. One is the bl…

3-33
3
Periodic maintenance items
4.2 Checking the ejector vacuum pressure
Check the vacuum level of each ejector of the ejector unit to see if it is working correctly.
When the level does not reach the specified vacuum level, the valve or the ejector BIT may need to be
replaced. See chapter 6, "3.Ejector unit" to replace the valve or the ejector BIT.
e
1
Move the head unit forward.
1. Press the emergency stop button and
then open the machine safety cover.
2. If the machine is equipped with a
carriage, remove the carriage to allow
you to easily access the head.
3. Move the head unit forward.
2
Remove the air hoses from the air
joints at the bottom of the head.
Remove all air hoses from the air joints at the
bottom of the head. Do not remove them at
the top.
53333-L4-00
3
Check the ejector vacuum level.
1. Open the [Unit] - [Head] screen.
2. Press the [Vacuum] button while blocking
the tip of air hose with your finger..
3. Make a note of the "Max" reading of
each head while the air hose is blocked,
and check that the reading is higher
than the criterion value below.
Make the same check for all heads.
54305-L4-10
n
Criterion of ejector vacuum level
When air joint is blocked: 190 or more
TIP
If the vacuum level of any head does not reach the
criterion value, then check the air path in the head
(interior of the spline shaft or air hose between the
ejector and spline shaft). Clean or replace it if
necessary
4
Return the air hoses to the original
position.
Disconnecting the air hoses
Step 2, 3
Air hose disconnected (transparent hose)
Block the air hose with your finger during measurement.
Bearing holder
Checking the vacuum levels
Step 3
Press the [Vacuum] button for each head.
Check "Max" vacuum levels
(with air joint blocked).

3-34
3
Periodic maintenance items
4.3 Operation check of head blow valve and cleaning blow valve
Check the operation of the head unit valve (solenoid valve). The head unit valve includes the following. One is
the blow valve that blows per head unit. The other one is the cleaning blow valve that blows strongly to clean
the inside of the shaft. If the valve does not work properly, it needs to be replaced. Replace it referring to
chapter 6, "3.2 Replacing a valve (solenoid valve)" and "3.3 Replacing the cleaning blow valve".
c
CAUTION
A strong air flow is exhausted during the cleaning blow. Always remove all nozzles attached to the heads before
starting the cleaning blow. Starting the cleaning blow while the nozzles are still attached may blow the nozzles away
from the heads causing the nozzles to break or become lost.
1
Remove the nozzles from all heads.
If nozzle station is equipped with the machine:
1. Press the [Nozzle Change] button on the
[Unit] - [Head] screen.
2. Select "ALL" for the Head Number and
select "Store Nozzle" for Nozzle type on
the "Nozzle Change" screen.
3. Press the [OK] button. The nozzles of all
heads are stored to the nozzle station.
54313-L4-00
n
NOTE
If the machine is not equipped with the nozzle station,
press the emergency stop button and then open the
machine safety cover to remove nozzles manually.
e
2
Move the head unit forward.
1. Press the emergency stop button and
then open the machine safety cover.
2. If the machine is equipped with a
carriage, remove the carriage to allow
you to easily access the head.
3. Move the head unit forward.
3
Blow each head.
Press all the [Blow] buttons on the [Unit] -
[Head] screen.
54306-L4-10
4
Check the blowing condition.
Place finger under each head. Check that
the air is exhausted equally from all heads. If
the less air is exhausted or the air is not
exhausted, a valve (solenoid valve) needs
to be replaced. Replace it referring to
chapter 6, "3.2 Replacing a valve (solenoid
valve)".
Storing nozzles
Step 1
Head Number : “ALL ”, Nozzle Type : “Store Nozzle”
[Nozzle Change] button
Blowing
[Blow] button
Step 2

3-35
3
Periodic maintenance items
5
Operate the cleaning blow valves.
1. Open the [Unit] - [I/O] screen.
2. Select "Head" from the Output drop-
down list. Select the address of the head
shaft blow (A table: T002C804/B table:
T102C804).
3. Press the [ON/OFF] button on the left
once. The address indication changes
from 0 to 1. The cleaning blow valve start
operating.
54307-L4-10
6
Check the cleaning blow condition.
1. Place finger under each head. Check
that the stronger air is exhausted from all
heads.
2. Press the [ON/OFF] button on the [Unit]
- [I/O] screen again. The address
indication changes from 1 to 0. The
cleaning blow valve is closed.
3. Check that the less air is exhausted
If the strength of the air exhausted from the
head does not change even operating the
cleaning blow valve, the cleaning blow
valve needs to be replaced. Replace it
referring to chapter 6, "3.3 Replacing the
cleaning blow valve".
c
CAUTION
Make sure to wear safety goggles as the exhausted air
blow may strike face.
7
Shut the blow valve OFF.
Press the [Blow] buttons of all heads on the
[Unit] - [Head] screen to stop the blow
operation.
8
Return the nozzles.
Return the nozzles to the original position if
they were removed from the head manually.
Operating the cleaning blow valves.
Step 3
Press the [ON/OFF] button. Select an address.
Select a head.