1 Introduction 1.4 Staff qualifications and training Assembly Instructions / Montageanleitung SIPLACE TX2i V1 SIPLACE TX2 V2 Option Mixed-Mode 01/2019 81 1.3.5 Release History Document SIPLACE TX2i V1 SIPLACE TX2 V2 Mixe…

100%1 / 134
1 Introduction
1.3 Other Instructions
80 Assembly Instructions / Montageanleitung SIPLACE TX2i V1 SIPLACE TX2 V2 Option Mixed-Mode 01/2019
1.3.3.3 Handling ESD modules
Do not touch electronic modules unless it is absolutely essential to do so in order to carry out other
work. If it is necessary, make sure that you do not touch the pins or printed conductors when you
pick up flat modules.
Do not touch components unless:
you are constantly earthed by an ESD wrist strap or
You are wearing ESD shoes or ESD shoe earthing strips on an ESD floor.
Always discharge yourself before you touch an electronic module. To do this, simply touch a con-
ductive and earthed object immediately before you touch the module (such as unpainted parts of a
switch cabinet, a water pipe, etc.).
Do not allow modules with chargeable and highly insulating materials to touch one another, e.g.
plastic films, insulating table surfaces or items of clothing made from synthetic fibers.
Always place the modules on a conductive surface (table with an ESD coating, conductive ESD
foam, ESD bag or container).
Do not move the assemblies near to data view devices, monitors or television units. Keep a min-
imum distance of 10 cm to monitors.
1.3.3.4 Measurements and modifications to ESD modules
Do not take measurements on the modules unless the following conditions are fulfilled:
The measuring device is earthed (e.g. via PE conductors) or
You discharge the measuring head just before taking measurements with a potential-free
measuring device (e.g. by touching an unpainted metal part of the controller casing).
Always use an earthed soldering iron if you carry out any soldering work.
1.3.3.5 Dispatching ESD modules
Always store modules and components in conductive packaging (e.g. metallized plastic bags
or metal sleeves) and dispatch them in conductive packaging.
If the packaging is not conductive, place the modules in a conductive envelope before pack-
aging. Use conductive expanded rubber, ESD bags, domestic aluminum foil or paper, for
example. NEVER use plastic bags or film.
If the module has integral batteries, ensure that the conductive packaging does not touch or
short circuit the battery terminals and, if necessary, first cover the terminals with insulating
tape or material.
1.3.4 Validity of Document
This document is valid for the following machine types:
SIPLACE TX2i V1
SIPLACE TX2 V2
The work described in this manual is divided into modules and is largely identical for all machine
types:
If the work required for specific machines differs from the standard procedure, this will be in-
dicated with reference to the machine number, series and delivery state.
Images are only shown as examples. For example, the illustration of a specific machine type
or a machine with different paint finish does not imply that the information following the illus-
tration only applies to the shown machine type.
Please read the circuit diagram folder for any electrical checks.
Detailed circuit diagrams folder for SIPLACE TX V1-Series (up to no. 499) [DE+EN: 00197933-xx]
Detailed circuit diagrams folder for SIPLACE TX V1-Series (from no. 500) [DE+EN:00198274-xx]
Detailed circuit diagrams SIPLACE TX V2-Series [DE+EN: 00198460-xx]
1 Introduction
1.4 Staff qualifications and training
Assembly Instructions / Montageanleitung SIPLACE TX2i V1 SIPLACE TX2 V2 Option Mixed-Mode 01/2019 81
1.3.5 Release History
Document
SIPLACE TX2i V1
SIPLACE TX2 V2
Mixed mode option
Assembly Instructions
Edition Amendments
11/2017 Initial release
01/2019 SIPLACE TX2 V2 machine added
1.4 Staff qualifications and training
Qualified or adequately trained personnel means that these people are familiar with the setting up,
operation and maintenance of the machine and the add-on devices and are suitably qualified, e.g.:
Have been trained, instructed or authorized to switch on and off, isolate, earth and identify
electrical circuits and system components in accordance with normal safety standards.
Have been trained or instructed in the upkeep and use of appropriate safety equipment in
accordance with normal safety standards.
Have received first aid training.
1.5 Abbreviations
Abbreviation Description
COT Changeover table
COT-i Changeover table insert
C&P Collect&Place
C&P12, CP12 Collect&Place head with 12 segments
C&P20, CP20 Collect&Place head with 20 segments
C&P20x Collective term for all C&P20 heads (e.g. C&P20, C&P20A, C&P20P,
C&P20P2)
C&P6, CP6 Collect&Place head with 6 segments
CPP Collect&Pick&Place head
NC Nozzle changer
1 Introduction
1.5 Abbreviations