00198536-02_AI_Mixed-Mode_TX2iV1_TX2V2_de_en.pdf - 第90页

3 Installation 3.2 Adapting the hose connections at the pneumatics block 90 Assembly Instructions / Montageanleitung SIPLACE TX2i V1 SIPLACE TX2 V2 Option Mixed-Mode 01/2019 Fig.16: Overview of the three chambers in the…

100%1 / 134
3 Installation
3.2 Adapting the hose connections at the pneumatics block
Assembly Instructions / Montageanleitung SIPLACE TX2i V1 SIPLACE TX2 V2 Option Mixed-Mode 01/2019 89
3.2.2 Creating access to the pneumatics block and modifying the hose
connections
NOTICE
The following description shows the conversion for configuration of gantry1 with C&P20x
head (vacuum pump) and gantry2 with CPP head.
The procedure for configuration of gantry2 with C&P20x head (vacuum pump) and gantry1
with CPP head is the same.
NOTICE
Do not loosen the screws of both trailing interfaces at the same time.
Begin with the trailing interface for the gantry without vacuum hoses (gantry with
CPP).
Overview - pneumatics block
Fig.15: Connections on the pneumatics block (using a SIPLACETXV2 as example)
1 Pneumatic hose PUN12 from proportional valve (compressed air place-
ment circuit inlet)
2 5x connections for the 7-fold hose in the trailing cable Gantry 1
3 2x vacuum hoses (Camozzi) Gantry 1
4 2x connections 7-fold hose (placement circuit outlet) Gantry 1
5 2x connections 7-fold hose (placement circuit outlet) Gantry 2
6 5x connections for 7-fold hose Gantry 2
7 2x vacuum hoses (Camozzi) Gantry 2
8 Fabric hose vacuum
9 Fabric hose compressed air or vacuum
3 Installation
3.2 Adapting the hose connections at the pneumatics block
90 Assembly Instructions / Montageanleitung SIPLACE TX2i V1 SIPLACE TX2 V2 Option Mixed-Mode 01/2019
Fig.16: Overview of the three chambers in the pneumatics block with the according connections (Using a
SIPLACETXV2 as example)
Item in
figure
Initial situation With mixed mode
Without vacuum pump With vacuum pump
1 Compressed Air Compressed Air Compressed Air
2 Compressed Air Vacuum Compressed Air
3 Not connected Vacuum Vacuum
3 Installation
3.2 Adapting the hose connections at the pneumatics block
Assembly Instructions / Montageanleitung SIPLACE TX2i V1 SIPLACE TX2 V2 Option Mixed-Mode 01/2019 91
Overview - conversion of the hose connections
Fig.17: Overview of pneumatics block conversion (using aSIPLACETXV2, as example with gantry 1: vacuum,
gantry 2: compressed air)
1. Removing the Camozzi hoses 6 and 7 (gantry 2')
2. Connecting the two hoses using Y pieces
3. Disconnecting the hoses 1 to 5 (gantry 1)
4. Sealing the connections 1 to 5 (gantry 1)
5. Sealing hose 5
6. Disconnecting the hoses 1 to 4 (gantry 1) to the Y pieces
Steps 1 and 2 are described in section 3.2.2.1 "Gantry without vacuum hoses (gantry with
CPP)" [}92].
Steps 3 to 6 are described in section 3.2.2.2 "Gantry with vacuum hoses(gantry with
C&P20x)" [}94].