Settings Adjustment of air pressure values C&P12 Service Manual SIPLACE D4 233 6.3.1 1.3 Setting the Air Bl ast Pressure V alues with the Compressed Air T esting Device Adjust to the values of the table below: Repeat…

Settings
C&P12 Adjustment of air pressure values
232 Service Manual SIPLACE D4
6.3.11 Adjustment of air pressure values
6.3.11.1 Tools and Equipment
A set of slotted screw drivers
Compressed air testing device
6.3.11.2 Setting the Air Blast Pressure Values
6-20: Adjustment of air pressure values
Legend
1. Forced air unit
2. Micro-relay valve
3. Adjustment valve for the reject circuit
4. Adjustment valve for the pickup / placement
circuit
NOTE:
Use a nozzle of type 914 to set the air
blast. Press in the spring from the
nozzle interface during the
measurement and read the value from
the display.

Settings
Adjustment of air pressure values C&P12
Service Manual SIPLACE D4
233
6.3.11.3 Setting the Air Blast Pressure Values with the Compressed Air Testing Device
Adjust to the values of the table below:
Repeat these adjustments several times, as the pickup / placement circuits are mutually dependent.
6-21: Flow chart determining air pressure values
When setting the air blast value with the
compressed air device and the adjustment valve,
observe the following:
X Press the nozzle upwards during the
measurement process!!
NOTE:
The air blast values which are shown in
the
Measured Air Blast
menu, on the
station computer screen, at
Single
Functions
or in the SITEST program,
do not reflect the air blast values really
set at the nozzle. They are used to
check that the air blast valve is
functioning correctly. Therefore, do not
use the values shown on the screen to
set the air blast. Instead, use only the
values determined with the
compressed air testing device.
Air Pressure Values Set with compressed air testing device
Measured at nozzle:
Displayed on the monitor:
(Only in pickup and placement
circuit)
pickup / placement circuit 150 mbar (100 - 200 mbar) e.g.: 250 mbar
Reject circuit 250 mbar (200 - 300 mbar) Reject circuit does not have a sensor
NOTE:
The two air blast circuits are controlled via a single valve and therefore influence one another
mutually. However, two different adjustment valves (see items 3 and 4 in the diagram above)
can be used to set the various pressures for each circuit.
NOTE:
Make sure the measurement sensor hose is fitted tightly on the nozzle.

Settings
C&P12 Performing a Vacuum Test on the C&P 6/12 DLM Heads
234 Service Manual SIPLACE D4
6.3.12 Performing a Vacuum Test on the C&P 6/12 DLM Heads
Damage to the valve plunger, silicone hose, the vacuum plate, in or on the nozzle can lead to leakage
which may then cause malfunctions during the placement process or which may reduce the vacuum
value in the holding circuit.
Vacuum test with normal nozzle
configuration
The vacuum tests for C&P6/12 in the station
software of the C&P12/6 placement heads
only checks the area from the vacuum
generator to the valve plungers.
The area visible here (red frame), from the
valve plunger housing via the silicone hose
into the segment housing and through the
sleeve to the nozzle is not covered by the
normal vacuum test.
Equipment required
Closed nozzle tips are required for checking the
complete vacuum circuit.
The special nozzle use for this is marked red and
does not have a nozzle configuration on it:
SOKO nozzle for vacuum test DLM, Item No.
[03067029-01]