00195366-01_InstallationManual_EDM_en.pdf - 第27页
Installation Manual SIPLACE EDM Edition 11/2006 The following shows the basic struct ure of an EDM configuration file: <configuration> <!- - This is a comment - - > <appSetting> <add key=“ masterServ…

Installation Manual SIPLACE EDM Edition 11/2006
Time specification in the format “P0Y0M0DT0H15M0S”
Time
Class .NET class in the format “[ClassName][,Assembly]?”
Path Windows path specification
File Windows file specification
Endpoint Communication endpoint. The exact format depends on the transfer protocol.
Section Subsection with several values. The entries valid for each key are shown in the corresponding
explanation.
C Valid for: clearing pool
L Valid for: line server
M Valid for: master server
T Valid for: EDM Tool
R Required
D Default value. Input is only necessary if a different setting is desired.
Table 6 Legend
26 of 66

Installation Manual SIPLACE EDM Edition 11/2006
The following shows the basic structure of an EDM configuration file:
<configuration>
<!- - This is a comment - - >
<appSetting>
<add key=“masterServer” value=“localhost”/>
<add key=“notificationInterval” value=“P0Y0M0D0H15M0S”/>
Value
Time
</appSettings>
Key
<! - - This is a configuration parameter of the type “Section” - ->
<endpointConfig>
Endpoint
<add key=“spc10047c” value=“private$\EDM”/>
</endpointConfig>
Section
<! - - These are the services provided by the master server - - >
<requestCommandConfig>
<add key="objectData" value=
"Siemens.SiplacePro.EDM.DataExchange.Commands.RequestDataCommand,DataExchange"
/>
Class
</requestCommandConfig>
</configuration>
The keys and sections permitted are shown in the following table:
Key Format Type Contents
clientWorkflowConfig File L;D File with EDM client process
definition (5.2.3.21)
commentCategories Section M;T Comment categories for change
notifications (5.2.3.29)
communicationTimeout Time L;M;C;D Timeout für Kommunikation zw.
Line und Master-Server (5.2.3.16)
compressionType Enum L;M;C;D Compression for data transfer
(5.2.3.20)
customConfig Section L;M ;C ;T Space for additional attributes
(5.2.3.32)
edmToolEndPoint Endpoint L;M;T;R End point for messages to the EDM
27 of 66

Installation Manual SIPLACE EDM Edition 11/2006
tool. (5.2.3.14)
endpointConfig Section M;R Endpoint configuration for the
exchange of data (5.2.3.15)
helpDirectory Path L;M;C;T;
D
Path for help files (5.2.3.2)
incomingClearingPoolRequests Endpoint M;C;R Endpoint for incoming queries to
the clearing pool (5.2.3.13)
incomingNotifications Endpoint M;R Endpoint for incoming change
notifications to the master
(5.2.3.12)
incomingRequests Endpoint M;R Endpoint for incoming change
queries to the master (5.2.3.11)
machineAliasNames Section L;M;C;R Assignment of readable names to
the network IDs of the individual
EDM computers (line servers,
clearing pool, etc.) (5.2.3.31)
masterNotifications Endpoint L;R Destination for change notifications
(5.2.3.10)
masterRequests Endpoint L;C;R Requests to the master server
(5.2.3.9)
masterServer String L;M;C;R Network identification of the master
server (5.2.3.7)
notificationDistributorClass Class M;D Class for external notifications (e.g.
email) (5.2.3.3)
notificationDistributorConfiguratorClass Class M;D Configuration for external
notification system (e.g. email)
(5.2.3.4)
notificationInterval Time L;D Time to transfer the change
notification to the master (5.2.3.5)
notificationStorage Endpoint L;D Buffer for change notifications
(5.2.3.6)
responseTimeout Time L;D Timeout for replies from the master
(5.2.3.19)
requestCommandConfig Section M;R Scope of functionality of master
server (5.2.3.30)
serverType Enum L;M;C;R Operating mode of the installation
(5.2.3.1)
28 of 66