Installation Manual SIPLACE EDM Edition 11/2006 5.2.3.15 Endpoint configuration Key: endpointConfig Section Type: Master server Valid for: Description: This section contains pairs of values of the form: <add key="…
Installation Manual SIPLACE EDM Edition 11/2006
5.2.3.12 Incoming change notifications
Key: incomingNotifications
Endpoint Type:
Master server Valid for:
Description: Endpoint at which the master server listens in for incoming change notifications.
Determines the value for “outgoing change notifications” on the line servers.
The value must be different from the value for “incoming requests”.
5.2.3.13 Incoming clearing pool requests
Key: incomingClearingPoolRequests
Endpoint Type:
Valid for: Master server
Clearing pool
Endpoint at which the clearing pool listens for incoming commands from the master
service.
Description:
5.2.3.14 EDM tool endpoint
Key: edmToolEndPoint
Endpoint Type:
EDM_SPI_REMOTE_HOST:9002/EdmTool
Default:
Valid for: Master server
Line server
EDM Tool
Description: Endpoint for entering change notifications. The default value means that the
comment dialog boxes always open on the computer at which the SPI event
was triggered that caused the notification which requires a comment (if an EDM
tool is installed there).
If the line engineer is to enter the comments at a different computer, replace
EDM_SPI_REMOTE_HOST in the configuration file of the line server with the
host name of this computer.
34 of 66
Installation Manual SIPLACE EDM Edition 11/2006
5.2.3.15 Endpoint configuration
Key: endpointConfig
Section Type:
Master server Valid for:
Description: This section contains pairs of values of the form:
<add key="[hostname]" value="[Endpoint]"/>
There is one pair of such values for each line server. This list describes the
connections from the master server to the line servers to be used.
The network ID (not the alias) of the computer concerned must be entered under
hostname. You can also enter “*” or “all” as the value for hostname. This is then
used as the default value when no entry can be found for a specific line server.
Important: All line servers should always be listed in every configuration file. In
particular, the name of the local computer must be included (or at least an entry for
’*’).
5.2.3.16 Communication timeout
Key: communicationTimeout
Time Type:
P0Y0M0DT0H1M0S (= 1 minute)
Default:
Valid for: Line server
Master server
Clearing pool
Description: Time period in which a message must be received from a particular communication
partner. The setting should generally not be changed. The other options are as
follows (from left to right):
Y = years
M = months
D = days
H = hours
M = minutes
S = seconds
35 of 66
Installation Manual SIPLACE EDM Edition 11/2006
5.2.3.17 Use advanced EDM notification filtering
Key: useAdvancedNotificationFiltering
String (“true”/”false”) Type:
true Default:
Master server Valid for:
Description: Activation/deactivation of direct import/rejection of notifications by the master
server.
If these filters are deactivated, all notifications are entered in the clearing pool. If
they are activated, changes to objects can be accepted/rejected without first being
displayed in the clearing pool (for configuration, see sections 5.4.3 and 5.4.4).
5.2.3.18 Modified object protection
Key: useModifiedObjectProtection
String (“true”/”false”) Type:
true Default:
Line server Valid for:
Description: Activation/deactivation of the overwriting of modified objects in the line server.
If this object is activated, objects which are currently in the clearing pool are not
overwritten with the (older) data from the master server during a pull operation.
5.2.3.19 Response timeout
Key: responseTimeout
Time Type:
P0Y0M0DT0H5M0S (= 5 minutes)
Default:
Line server Valid for:
Description: Time period in which the line server considers a reply to a service request from the
master server to be valid. Timing problems can arise here due to the interaction
between SIPLACE Pro and XML Import/Export that may require a change to be
made. However, the timeout should not be set to a value too high since this can
cause the users to become very irritated.
The other options are as follows (from left to right):
Y = years
36 of 66