00195366-01_InstallationManual_EDM_en.pdf - 第31页

Installation Manual SIPLACE EDM Edition 11/2006 5.2.3.4 Configuration of EDM notification traffic Key: notificationDistribut orConfiguratorClass Class Type: Siemens.SiplacePro.EDM.UserInterface.EmailConfigurator, UserInt…

100%1 / 66
Installation Manual SIPLACE EDM Edition 11/2006
5.2.3.1 Server type
Key: serverType
Enum Type:
Values: LINE
MASTER
BOTH
CLEARINGPOOL
Valid for: Line server
Master server
Clearing pool
Specifies the type of installation. The EDM server is started as a line server, master
server or hybrid depending on this setting (should only be used for test purposes).
Description:
5.2.3.2 Help directory
Key: helpDirectory
Path Type:
[AppDir]\help
Default:
Valid for: Line server
Master server
Clearing pool
EDM Tool
Directory for online documentation Description:
5.2.3.3 Distribution list for EDM notifications
Key: notificationDistributorClass
Class Type:
Default:
Siemens.SiplacePro.EDM.DataExchange.EmailDistributor,
DataExchange
Master server Valid for:
Class, i.e. implementation of the notification service. At the present, distribution via
email is available using the default value as a reference.
Description:
30 of 66
Installation Manual SIPLACE EDM Edition 11/2006
5.2.3.4 Configuration of EDM notification traffic
Key: notificationDistributorConfiguratorClass
Class Type:
Siemens.SiplacePro.EDM.UserInterface.EmailConfigurator,
UserInterface
Default:
Master server Valid for:
Configuration dialog box for the notification service. The actual configuration of the
notification service depends on its implementation. Configuration of an email
service referenced using the default value is currently supported.
Description:
5.2.3.5 Notification interval
Key: notificationInterval
Time Type:
P0Y0M0DT0H15M0S (= 15 minutes)
Default:
Line server Valid for:
Description: Time period during which the change notifications will be collected on the line
servers before they are sent to the master server. The other options are as
follows (from left to right):
Y = years
M = months
D = days
H = hours
M = minutes
S = seconds
The period should not be shorter than 5 minutes.
5.2.3.6 Notification storage
Key: notificationStorage
Endpoint Type:
notificationStorage
Default:
Line server Valid for:
Buffer for collected change notifications. Description:
31 of 66
Installation Manual SIPLACE EDM Edition 11/2006
5.2.3.7 Master server
Key: masterServer
String Type:
Valid for: Line server
Master server
Clearing pool
Network ID of the master server. Windows computer name only. IP addresses are
not permitted.
Description:
5.2.3.8 Transceiver
Key: transceiverClass
Class Type:
Default:
Siemens.SiplacePro.EDM.DataExchange.MsmqTransceiver,
DataExchange
Valid for: Line server
Master server
Clearing pool
EDM Tool
Implements the data transfer between the line servers and master server. This entry
must be identical on all installed systems. The exact format of the “endpoint” values
depend on this value. The default setting uses MSMQ to transfer the data.
Description:
Endpoint: An endpoint entry has the following format for the MSMQ transceiver:
Private$\[queue-name].
Note that private queues absolutely must be used here. Only private queues can be
used in both a domain/active directory-based network environment as well as in a
pure workgroup installation.
32 of 66