00195366-01_InstallationManual_EDM_en.pdf - 第53页

Installation Manual SIPLACE EDM Edition 11/2006 5.4 EDM configuration 5.4.1 Application templates As already mentioned, the application templates depict the static part of the cu stomer process that is related to the dat…

100%1 / 66
Installation Manual SIPLACE EDM Edition 11/2006
5.3.3 Default configuration
See 7.2. ClientWorkflow.xml
52 of 66
Installation Manual SIPLACE EDM Edition 11/2006
5.4 EDM configuration
5.4.1 Application templates
As already mentioned, the application templates depict the static part of the customer process that is
related to the data. They primarily define the object types to be transferred and whether or not they
will be overwritten.
5.4.1.1 General settings
Figure 16 General settings for application templates
The general settings include:
• Type of data transfer. Currently, you can only select “Pull Mode” or “Forced Pull Mode”.
• Starting Point specifies the object type for which this template is valid. A template can only be
valid for one object type at a time, though. It is possible, of course, to define more than one
template for an object type.
• Objects found in the default folder and all its subdirectories for the data transfer from the master
can be specified later on by the line engineer.
• An optional comment.
53 of 66
Installation Manual SIPLACE EDM Edition 11/2006
5.4.1.1.1 Pull mode
No additional settings can be specified for this type of data transfer between the master server and
line servers.
5.4.1.1.2 Forced pull mode
For this type of data transfer, the time after which the data preparation engineer will be notified that
no new data has been pulled for the line must be specified via “Configure”. The time is specified in
hours.
Figure 17 Forced Pull Mode configuration
5.4.1.2 Overwriting
Figure 18 Settings for overwriting object types
This is where you can select the object types to be overwritten when the data is imported to the line.
54 of 66