Installation Manual SIPLACE EDM Edition 11/2006 5.2.3.33 Advanced vision data actions Key: xmlImportVisionDataAdvancedAction Integer Type: 9 Default: Valid for: Line server Master server Clearing pool Sets the VisionData…
Installation Manual SIPLACE EDM Edition 11/2006
5.2.3.31 Aliases
Key: machineAliasNames
Section Type:
Valid for: Line server
Master server
Clearing pool
Description: The network ID of EDM computers is converted to an alias when it is displayed in
the EDM program components in order to make it more readable for humans. Enter
all the line servers in the overall EDM system in this section. This section contains
pairs of values of the form:
<add key="[string]" value="[string]"/>
The key is the network identification of an EDM computer (not an IP address, only
Windows computer names). The value can be any name different from the network
ID.
Important note: The assignment of the computer ID to the alias must be identical on
all EDM computers (master server, line server, clearing pool).
5.2.3.32 EDM VDM blob extensions
Key: useVdmExtension
String Type:
true
Default:
Valid for: Line server
Master server
Activates/deactivates EDM VDM blob extensions. If this option is activated,
UseVdmBlobExtension from the custom configuration must not be activated.
Description:
41 of 66
Installation Manual SIPLACE EDM Edition 11/2006
5.2.3.33 Advanced vision data actions
Key: xmlImportVisionDataAdvancedAction
Integer Type:
9
Default:
Valid for: Line server
Master server
Clearing pool
Sets the VisionDataAdvancedAction property of XmlImport. Description:
5.2.3.34 Customer configuration
Key: customConfig
Section Type:
Valid for: Line server
Master server
Clearing pool
EDM Tool
Description: This section contains pairs of values of the form:
<add key="[string]" value="[string]"/>
Valid key (default value):
Suppresses transfer of optimization results for jobs together with a notification.
Key (default):
skipOptimisationResultsForNotifications (true)
If true: Suppresses transfer of optimization results in job notifications.
preservePcbBarcodesDuringMasterImport (true)
If true: Never overwrites the PCB barcodes in the master database with (local)
barcodes from the line server.
useVdmBlobExtension (false)
If true: Activates EDM blob handling. This option should only be activated if this
is necessary for reasons of compatibility. It is recommended that you leave this
value set to “false” and use EDM blob handling.
If this option is activated, EDM blob handling must be deactivated with the entry
<add key="UseBlobExtension" value="false"/>.
CompatibilityMode (false)
If true: Allows restricted operation of the EDM line server together with an EDM
42 of 66
Installation Manual SIPLACE EDM Edition 11/2006
master server.
Caution: This mode must not be used for long-term mixed operation, but only
for gradual line-by-line upgrading of the EDM system (see 4.4).
doNotUseDefaultCategoryInCommentDialog (false)
doNotUseDefaultUserInCommentDialog (false)
doNotUseDefaultCommentInCommentDialog (false)
If true: Does not enter default values into the relevant field (category, user
name or comment) when the dialog box for entering a comment for a
notification is opened. This means that the contents must be entered manually
each time.
forceUserEntryInCommentDialog (false)
forceCommentEntryInCommentDialog (false)
forceCategoryEntryInCommentDialog (false)
If true: Forces the user to make an entry in the relevant field (category, user
name or comment) in the dialog box for entering a comment for a notification.
Empty entries are no longer accepted.
EdeUserControlOverride
This class name specifies the control used in place of the Extended Difference
Editor.
5.2.4 Configuration of the VDM blob functions
To use the VDM blob functions, the names of the SPI lines assigned to each line server must be entered
in the line server’s configuration file (see 5.2.3.24 Assigned SPI lines). If this section is left empty, blobs
are accepted for all lines.