00195366-01_InstallationManual_EDM_en.pdf - 第30页
Installation Manual SIPLACE EDM Edition 11/2006 5.2.3.1 Server type Key: serverType Enum Type: Values: LINE MASTER BOTH CLEARINGPOOL Valid for: Line server Master server Clearing pool Specifies the type of installation. …

Installation Manual SIPLACE EDM Edition 11/2006
serviceRemotingEndpoint String L;R .NET remoting configuration for
communication with the line service
(5.2.3.22)
spiLines Section L SPI lines associated with this line
server. (5.2.3.24)
startingPoints Section M List of permissible object types for
starting points (5.2.3.28)
sqlDataSource String C;M;R SQL Server access for the clearing
pool (5.2.3.24)
sqlUserName String C;M;R User name for SQL Server access
(5.2.3.26)
sqlUserPassword String C;M;R Password for SQL Server access
(5.2.3.27)
templateStorage Path L;M;D Storage location for application
templates (5.2.3.23)
transceiverClass Class L;M;C;T;
D
Class of data transfer (5.2.3.8)
useAdvancedNotificationFiltering String
(“true”/”false”)
M;D Activate/deactivate direct
import/rejection of notifications in
the master server (5.2.3.17)
useModifiedObjectProtection String
(“true”/”false”)
L;D Forced overwriting of changed
objects with older master data
(5.2.3.18)
useBlobExtension String
(“true”/”false”)
L;M;D Activates/deactivates EDM VDM
blob extensions (5.2.3.32)
xmlImportVisionDataAdvancedAction Integer L;M;C;D Sets the
VisionDataAdvancedAction
property of XmlImport.
Table 7 Contents of the configuration file
29 of 66
Installation Manual SIPLACE EDM Edition 11/2006
5.2.3.1 Server type
Key: serverType
Enum Type:
Values: LINE
MASTER
BOTH
CLEARINGPOOL
Valid for: Line server
Master server
Clearing pool
Specifies the type of installation. The EDM server is started as a line server, master
server or hybrid depending on this setting (should only be used for test purposes).
Description:
5.2.3.2 Help directory
Key: helpDirectory
Path Type:
[AppDir]\help
Default:
Valid for: Line server
Master server
Clearing pool
EDM Tool
Directory for online documentation Description:
5.2.3.3 Distribution list for EDM notifications
Key: notificationDistributorClass
Class Type:
Default:
Siemens.SiplacePro.EDM.DataExchange.EmailDistributor,
DataExchange
Master server Valid for:
Class, i.e. implementation of the notification service. At the present, distribution via
email is available using the default value as a reference.
Description:
30 of 66
Installation Manual SIPLACE EDM Edition 11/2006
5.2.3.4 Configuration of EDM notification traffic
Key: notificationDistributorConfiguratorClass
Class Type:
Siemens.SiplacePro.EDM.UserInterface.EmailConfigurator,
UserInterface
Default:
Master server Valid for:
Configuration dialog box for the notification service. The actual configuration of the
notification service depends on its implementation. Configuration of an email
service referenced using the default value is currently supported.
Description:
5.2.3.5 Notification interval
Key: notificationInterval
Time Type:
P0Y0M0DT0H15M0S (= 15 minutes)
Default:
Line server Valid for:
Description: Time period during which the change notifications will be collected on the line
servers before they are sent to the master server. The other options are as
follows (from left to right):
Y = years
M = months
D = days
H = hours
M = minutes
S = seconds
The period should not be shorter than 5 minutes.
5.2.3.6 Notification storage
Key: notificationStorage
Endpoint Type:
notificationStorage
Default:
Line server Valid for:
Buffer for collected change notifications. Description:
31 of 66