Order No. 00192 169-01 User Manual - Productivity Lift E_SPLFS03_V40_11_0300_200300_V1_14.doc Last update: 20.03.2000 - Version V 1.14 Page 13 The following must always be complied with: 1. A responsible person must keep…

Order No. 00192 169-01 User Manual - Productivity Lift
E_SPLFS03_V40_11_0300_200300_V1_14.doc Last update: 20.03.2000 - Version V 1.14 Page 12
3.2.6 General safety regulations
Please comply with the following general safety regulations:
• Follow the operating instructions
• In addition to the operating instructions, please also observe the relevant legal conditions
and regulations regarding accident prevention and environmental protection for the
country where the device is being used.
• Do not modify the device in any way without the written consent of the manufacturer.
• It is strictly forbidden to operate the device if protective equipment such as safety limit
switches, light barriers, emergency stopping switches or covers are dismantled or bridged.
• Only original spare parts obtainable from the manufacturer may be used for repairs.
• The service engineer or the qualified person must perform a test run after every
adjustment that is made to the device (maintenance, repair, etc.).
3.3 Other dangers
The device described here poses few other dangers. Please note the information on other
dangers and possible countermeasures in the following chapters.
3.3.1 Residual hazards for personnel
Please note the following residual hazards and possible countermeasures when working with
the device.
The danger of tripping over mains cables that have been laid incorrectly
ATTENTION
Lay the connecting cable in such a way that nobody can trip over it. Stick it firmly to the floor if
it can not be fed directly to the equipment either from above or below.
Key switch for bridging safety equipment
Figure 1: Key Switch
WARNING
Protective equipment such as covers and doors that are secured by safety key switches
interrupt the automatic operating mode if they are opened. This safety equipment can be
removed from service using a key switch in order to perform special operating functions, or to
provide the qualified person or service engineer with a better view for installation purposes.
These people are personally responsible for the safekeeping of the key.
Key Switch

Order No. 00192 169-01 User Manual - Productivity Lift
E_SPLFS03_V40_11_0300_200300_V1_14.doc Last update: 20.03.2000 - Version V 1.14 Page 13
The following must always be complied with:
1. A responsible person must keep the key to this switch somewhere where it is inaccessible
to others.
2. The qualified person or the service engineer may only use the key switch.
3. The key switch may only be used for the abovementioned purposes.
4. The safety key switches must be returned to service for the normal operating mode.
5. The person responsible must remove the key again.
6. The person responsible must lock the key away again.
N.B.
For safety reasons, the control cabinet doors can only be shut if the key has been removed
from the switch. In order to avoid damaging the key, particular attention must be paid to
removing the key carefully.
Set-up mode
WARNING
The fact that some safety equipment is taken out of service makes the system freely
accessible. This entails the risk of injury to people or damage to the system through
tampering. Therefore it is essential to ensure that during movements performed in the special
operating mode Installation, the equipment is not tampered with and that there are no objects
in it (e.g. tools). The qualified person or the service engineer in the installation operating
mode may only operate the equipment.
Maintenance and cleaning
ATTENTION
In order to maintain or clean the device the installation safety, described in 3.5.1, has to be
fixed and the device as well as air pressure of the filter regulation have to be switched off. The
main switch has to be locked with a personal padlock in order to avoid an unintentional switch
on. The subsequent requisite work must be carried out with due care and attention. In the
small interior space of the device, there is a slight risk that the person carrying out the work
could scratch themselves on corners or edges, although the production process does
endeavour to ensure that the parts have no sharp edges or corners.
Disconnecting compressed air supply
WARNING
Do not loosen a compressed air line without making sure that the corresponding air service
unit is pressureless by opening the handslide discharge valve or alternatively by closing the
main valve of the compressed air supply.
Code number
The code number requested in the configuration may only be known to one authorised person
and may not be passed on by this person to unauthorised persons.
3.3.2 Residual hazards for objects
There are no other factors that pose a threat to objects, property or the environment.

Order No. 00192 169-01 User Manual - Productivity Lift
E_SPLFS03_V40_11_0300_200300_V1_14.doc Last update: 20.03.2000 - Version V 1.14 Page 14
3.4 ESD guidelines
Please comply with the notes concerning the ESD guidelines as they are specified in the
operating instructions of the placement machine.