00192169-01.pdf - 第50页

Order No. 00192 169-01 User Manual - Productivity Lift E_SPLFS03_V40_11_0300_200300_V1_14.doc Last update: 20.03.2000 - Version V 1.14 Page 50 8.3 Manual mode 3  Shuttle Test function for the shuttle. The cursor keys  …

100%1 / 110
Order No. 00192 169-01 User Manual - Productivity Lift
E_SPLFS03_V40_11_0300_200300_V1_14.doc Last update: 20.03.2000 - Version V 1.14 Page 49
8 Manual mode
In the manual mode, the individual functions can be tested with the aid of the cursor keys.
The Hand key is used for changeover in the manual mode.
8.1 Manual mode 1  Lift 1
Test function for the top conveyor.
The cursor keys s and  t can be used to move the top conveyor upwards and downwards,
while the Alt key can be used to switch the belt drive on for as long as the key is pressed
down. The conveyor can only be moved downwards if the shuttle is in its lower position.
The Enter key can be used to proceed to the next test function. To cancel the procedure, exit
the menu using the Start/Stop key.
Hand
Stop
Start
Enter
Alt
Figure 65: Manual mode 1  Lift 1
8.2 Manual mode 2  Lift 2
Test function for the shuttle.
The cursor keys s and  t can be used to move the shuttle upwards and downwards, while
the Alt key can be used to switch the belt drive on for as long as the key is pressed down.
The shuttle can only be moved upwards if top conveyor is in its upper position.
The Enter key can be used to proceed to the next test function. To cancel the procedure, exit
the menu using the Start/Stop key.
Hand
Stop
Start
Enter
Alt
Figure 66: Manual mode 2  Lift 2
Manual mode 1
Lift 1
Manual mode 2
Lift 2
Order No. 00192 169-01 User Manual - Productivity Lift
E_SPLFS03_V40_11_0300_200300_V1_14.doc Last update: 20.03.2000 - Version V 1.14 Page 50
8.3 Manual mode 3  Shuttle
Test function for the shuttle.
The cursor keys s and  t can be used to move the shuttle in back and forth direction.
The Enter key can be used to proceed to the next test function. To cancel the procedure, exit
the menu using the Start/Stop key.
Hand
Stop
Start
Enter
Alt
Figure 67: Manual mode 3  Shuttle
8.4 Manual mode 4  underneath belt
Test function for the underfloor conveyor.
The cursor key s can be used to switch on the drive of the first segment (inlet) and the  t
key to switch on that of the second segment (outlet).
The Enter key can be used to proceed to the next test function. To cancel the procedure, exit
the menu using the Start/Stop key.
Hand
Stop
Start
Enter
Alt
Figure 68: Manual mode 4  underneath belt
8.5 Manual mode 5  Width lift 1
Function to set the width for the top conveyor.
The cursor keys s and  t can be used to increase and/or decrease the width of the
conveyor.
The Enter key can be used to proceed to the next test function. To cancel the procedure, exit
the menu using the Start/Stop key.
Hand
Stop
Start
Enter
Alt
Figure 69: Manual mode 5  width lift 1
Manual mode 3
Shuttle
Manual mode 4
underneath belt
Manual mode 5
Width lift 1
Order No. 00192 169-01 User Manual - Productivity Lift
E_SPLFS03_V40_11_0300_200300_V1_14.doc Last update: 20.03.2000 - Version V 1.14 Page 51
8.6 Manual mode 6  Width lift 2
Function to set the width for the shuttle.
The cursor keys s and  t can be used to increase and/or decrease the width of the
conveyor.
The Enter key can be used to proceed to the next test function. To cancel the procedure, exit
the menu using the Start/Stop key.
Hand
Stop
Start
Enter
Alt
Figure 70: Manual mode 6  width lift 2
8.7 Manual mode 7  Width belts
Function to set the width for the underfloor conveyor.
The cursor keys s and  t can be used to increase and/or decrease the width of the
conveyor.
The Enter key can be used to return to the first test function. To cancel the procedure, exit
the menu using the Start/Stop key.
Hand
Stop
Start
Enter
Alt
Figure 71: Manual mode 7  width belts
9 Automatic tracking option available
The Productivity Lift can be fitted with two types of automatic tracking.
1. Tracking via hybrid light barriers
2. Tracking via CAN bus
9.1 Automatic tracking via hybrid light barriers
The system is equipped with an automatic tracking facility for the transport width.
In the automatic operating mode, the transport width is tracked automatically. Built-in hybrid
light barriers detect the position of the mobile transport cheek of the previous or following
device and automatically adapt the transport width of the lift. The sensor mechanism detects
the direction in which adjustment is made and proceeds accordingly. If signals overlap, a
reference run is performed. In this case, the width setting is increased to the maximum width
and then the transport width is reset.
Manual mode 6
Width lift 2
Manual mode 7
Width belts