Autosite_Users_Manual.pdf - 第20页

Introduc tion 1-6 Aut oSi te User Manua l Safety AutoSite is certified by UL, CSA, and TUV to comply with the following safety standa rds: Underwr iters La borat ories —UL 1950 Canadian St andards Associati on —CSA C22.2…

100%1 / 175
Introduction
AutoSite User Manual 1-5
Specifications
Functional
RAM
8 MB standard (on units shipped after July
1997)
Disk Format, Floppy
Double-sided, Quad-density 3.5-inch disk
with 135 tracks per inch. 1.44MB formatted
Disk Format, MSM
(optional hard drive)
Minimum of 80MB
Controller
Motorola 68000 16-bit microprocessor
Terminal Support
Interfaces with ANSI 3.64 compatible
terminals, IBM PCs and compatibles
running a terminal emulator program, and
many popular ASCII terminals
Communication
Standard
RS-232C
Data transfer rate
110 to 19.2 K baud (up to 115.2K baud
using TaskLink)
Power Requirements
Operating Voltages
90 to 264 Vac
Frequency Range
50–60 Hz
Power Consumption
150 VA maximum
Input Current
1.5A maximum
Physical and
Environmental
Dimensions
Control unit:
Pin driver head:
Weight
7.7 kg (17 lbs.)
Temperature
Operating: +5° to 40°C (+40° to 105°F)
Storage: +5° to 50°C (+40° to 122°F)
Transportation:
-40° to +55°C (-40° to +130°F)
Relative Humidity
Operating: to 80% noncondensing
Storage: to 90% noncondensing
Altitude
Operating: to 15,000 meters
17.15h x 33.65w x 28.5d cm
6.75h x 13.25w x 11.25d in.
8.9h x 27.3w cm
3.5h x 10.75w in.
Introduction
1-6 AutoSite User Manual
Safety
AutoSite is certified by UL, CSA, and TUV to comply with the following
safety standards:
Underwriters Laboratories
—UL 1950
Canadian Standards Association
—CSA C22.2 No. 231
Technischer
Überwachungsverein
TUV GS-Mark Certification
EN60950
Electrostatic
Discharge (ESD)
IEC 801-2 (± 8 kV)
Certificate of RFI/
EMI Compliance
The following paragraph applies to all units shipped after January 1996:
Data I/O certifies that the AutoSite complies with the Radio Frequency
Interference (RFI) and Electromagnetic Interference (EMI) requirements
of EN55022 Class A and EN50082-1 as called out in 89/336/EEC, the
EMC Directive for the European Community.
-EC conformity mark
WARNING: This equipment is a class A product. In a domestic
environment this product may cause radio interference in which case
the user may be required to take adequate measures.
Performance
Verification
AutoSite verifies internal voltages every time it is powered up and every
time a complete self-test is run. The voltage verification is performed by
software and is compared to a laser-trimmed voltage reference. Data I/O
recommends that you cycle power AND run a complete self-test cycle at
least every three months. Contact Data I/O for information on checking
the reference voltage and the master clock.
To ensure that your AutoSite continues to meet product performance
specifications, Data I/O recommends that your programmer be returned
to an authorized Data I/O Service Center every twelve months for a
complete performance evaluation.
R
R
PRODUCT
SERVICE
geprufte
Sicherheit
Introduction
AutoSite User Manual 1-7
Options
The items listed below complement the AutoSite Automated Production
Programmer. For more information, or to order an item below, contact
Data I/O Customer Support as listed in the Preface.
Keep Current Subscription
Service
Data I/O offers a one-year subscription to keep your programmer and
documentation up-to-date with the latest features and device support.
This subscription also incorporates manufacturer-recommended changes
to existing device support to maintain optimum yields, throughput, and
long-term reliability.
In addition, you receive immediate access to new and updated
programming algorithms via our Keep Current Bulletin Board System
(BBS)—up to three months before the algorithms are available in an
update kit.
For more information, see the Keep Current documentation located
behind the Keep Current tab, or contact Data I/O Customer Support.
TaskLink Software
TaskLink is PC/programmer interface software designed for use with
AutoSite and other Data I/O programmers. TaskLink runs on an IBM PC
(or compatible) and allows you to control AutoSite from a personal
computer for streamlined and enhanced programming operations.
TaskLink features automatic programming file configuration, full-screen
editing, and error-logging. TaskLink also features a windowed interface,
extensive online context-sensitive help, and full mouse support.
88-pin Upgrade Kit
The 88-pin upgrade kit contains all the hardware and software required
to convert your 44-pin AutoSite into an 88-pin AutoSite.
Mass Storage Module
The Mass Storage Module provides the storage space required to store
the growing number of device programming algorithms for AutoSite. In
addition, the extra storage space provided by the Mass Storage Module
allows for additional commands and features to be added without
hampering normal operation in a production environment. Specifically,
the MSM virtually eliminates the need to swap disks under normal
programming operation.
Once the MSM is installed, the AutoSite system software can easily be
installed on the MSM. During normal operation, the MSM is virtually
transparent.
Stand-alone Kit
Provides DIP and PLCC support to the AutoSite programmer in stand-
alone mode. Includes a DIP Base, a PLCC Base, and a set of MatchBook
device carriers that provide support for 20-pin to 84-pin PLCCs. The
stand-alone kit is best suited for diagnostics and single-device
programming.