IPC9850_Surface Mount Equipment Characterization.pdf - 第37页

IPC-9850 Official Proposal May 2001 37 Reliability Performance Form IPC-9850-F2 Attribute defect rate and Reliability numbers are not to be construed as guarantees in any way. They simply indicate actual levels of reliab…

100%1 / 56
IPC-9850
Official Proposal
May 2001
36
7 Forms and Diagrams
The forms and diagrams on the following pages may be freely copied and reproduced. Contact IPC for electronic
copies of the forms. [web download after this is published]
Placement Performance Form
IPC-9850-F1
Manufacturer Name When form is used for ship
verification
Machine Model Serial Number
Build Date and Time
Component Type QFP-100 QFP-255 BGA-228 1608C SOIC-16
Test Conditions During Build
Number of Heads/Spindles
Type of Heads/Spindles
Type of Camera
Number of Feeders/Trays
Type of Nozzles
Number of Nozzles
Number of Panels Built 4 4 4 4 4
Number of Parts Per Panel 36 30 36 400 (120 for
CMM meas.
validation)
80
Test Results
Build Time, seconds
Transfer Time, seconds
Tact Time, seconds
Net Throughput, CPH
Repeatability (One Standard Deviation)
X, micrometers
Y, micrometers
Axis
θ, degrees
Accuracy
+X, micrometers
+Y, micrometers
Spec. Limits
1
for
Cpk=1.33
+θ, degrees
+X, micrometers
+Y, micrometers
Spec. Limits
1
for
Cpk=2.0
+θ, degrees
50% Coverage N/A
2
Cpk for
Termination-to-Land
75% Coverage N/A
2
Note 1 : To be valid, reported Spec. Limits must not exceed the Spec. Limits of the CMM capability reported in
form IPC-9850-F3.
Note 2: Termination-to-Land evaluation for 1608 components is not required. See Section 3.4.3.2.2 for details.
Form 9850-F1 Performance, issue date
IPC-9850
Official Proposal
May 2001
37
Reliability Performance Form
IPC-9850-F2
Attribute defect rate and Reliability numbers are not to be construed as guarantees in any way. They simply indicate
actual levels of reliability for this equipment achieved at customer locations.
Manufacturer Name
Machine Model
Attribute Defect Rate (ppm)
Specified Components Alternate Components Used
Component
Type
Quantity Component
Type
Quantity
SOT-23 440
SOIC-8 440
1608C 880
1608R 880
1005C 880
1005R 880
Mean Placements Between Assists (MPBA)
Mean Time To Recover from assists (MTTR
a
), minutes
Mean Placements Between Failures (MPBF)
Mean Time To Repair failures (MTTR
f
), hours
Equipment Dependent Uptime, %
Amount of Preventative Maintenance per 6000 Hours, hours
Mispick Rate (ppm)
Data Collected From:
Number of Factories
Number of Machines
Total Number of Placements
Form 9850-F2 Reliability, issue date
IPC-9850
Official Proposal
May 2001
38
CMM Capability to Evaluate Metric Parameters
IPC-9850-F3
Machine
Axis
Repeatability & Reproducibility,
GR&R Limits
1
Accuracy, Spec. Limits
1
Date of GR&R Study
__________
Glass
Slugs
2
1608 Cap SOIC-16
Glass
Slugs
2
1608
Cap
SOIC-16
X,
micrometers
Y,
micrometers
Placement Verification
Glass Panel
θ, deg
X,
micrometers
Y,
micrometers
Measurement Capability
Glass Panel
θ, deg
Note 1: To be valid, reported Spec. Limits in form IPC-9850-F1 must not exceed worse case Spec. Limits of the CMM
capability per component type.
Note 2: Since the CMM utilizes the fiducial markings on all glass slugs, regardless of the specific component image, it is only
necessary to evaluate the CMM’s ability to measure the slugs using the fiducial markings.
Form 9850-F3 CMM Capability, issue date