IT Feeder Manual-45Series(English V2.0)Ver5.pdf - 第50页

Samsung Intelligent Feeder System Figur e 2-15. Configuration scr een The configuration screen consists of 7 areas. Administration Password change: Changes the password for the management mode.  The 3 edit boxes underne…

100%1 / 82
Part Station
2-17
Figure 2-13. Part Station Program Exit screen
2.4. Option menu
When the Option menu is selected on the Main menu bar, the following 2 submenus
appear.
Configuration
Sets basic configuration for PartStation.
User Change
Changes the user mode of PartStation. The user mode consists of regular mode and
management mode.
Figure 2-14. Option screen
2.4.1. Configuration [F10]
When Configuration is selected from the Option menu, the following screen appears.
Samsung Intelligent Feeder System
Figure 2-15.Configuration screen
The configuration screen consists of 7 areas.
Administration Password change: Changes the password for the management mode.
The 3 edit boxes underneath are codified so that the letters entered are not visible.
<Old Password> edit box: Enter the previous password.
<New Password > edit box: Enter the new password.
<New Password Confirm> edit box: Enter the new password to confirm.
Reference
<Change> button is used for changing to a new password.
A password can be composed of a maximum 7 characters including Alphabets, Korean
characters and number keys. Special keys cannot be used. If setup is performed without
pressing any key, the password cannot be changed afterward.
Log In Database
<User ID> edit box: Enter the user ID to access the Oracle Database.
<Password> edit box: Enter the password to access the Oracle Database.
<Host String> edit box: Enter the host string to access the Oracle Database.
Feeder Scanner
The set up screen for the Feeder RF-ID scanner, it is not used in PartStation. It is used
in FeederStation.
Barcode Scanner Type
There are two types of barcode scanners; keyboard type and serial type. KeyBoard
Edge type is supported by PartStation.
2-18
Part Station
2-19
If help is needed to specify Serial Parameter when setting up the Serial Port type,
It is programmed to support only the keyboard edge type supplied by us.
2.4.2.
nu will display the following screen.
please consult with Samsung Techwin.
User Change [F11]
Selecting User Change in the Option me
Figu onfiguration dialog box
eted (it is possible in the case of
nd the setup cannot be performed.
In the administrator mode, the part/reel can be deleted and setup can be performed.
2.4.3.
etry connection to the Oracle Database when it is disconnected.
2.5. View Menu
hen the check button is
re 2-16. C
Users
Perform Part Station in the general user mode.
In the general user mode, the part/reel cannot be del
waste part-reel), a
Administrator
Perform Part Station in the administrator mode.
Connect Database [F12]
R
When the View menu is selected on the Main menu bar, the following submenus appear.
The View menu consists of the basic tool bar and status bar provided by Windows and the
ShowSyncApp menu that shows the status of DBSync program active in the background.
As default, the tool bar and the status bar are displayed. W
removed, the tool bar and status bar are invisible on the screen.
igure 2-17.View submenus
2.5.1.
F
Toolbar submenu
By turning On/Off the Toolbar in View of the Main menu, the user can have a screen with
the tool bar visible or invisible. Major commands of the Main menu are represented by