00195398-0103-AI-01005Paket_DE_EN.pdf - 第62页

Asse mb ly In st ruct i on s 0100 5- Pac ket E di tio n 1 2 /20 07 62 3.7. 2.2 Controlling a nd Configuring Advanced Set tings, w here ne cessary Æ S elect the "Advanc ed Edits" t ab. Æ G o to "Check compo…

100%1 / 76
Assembly Instructions 01005-Packet
Edition 12/2007
61
3.7.2.1 Configuring the Automatic Pickup Correction
Æ Select the "Basic handling" tab.
Æ Activate the checkbox "Automatic Pickup Correction".
Æ Check the default settings and make corrections, if necessary.
Æ Go to "Pickup Position" => "z" and enter the value -0,095 mm to adjust the head space height.
Æ Go to "Pickup vacuum => and select "Early vacuum".
Æ Enter a "Placement Force" of 1.0 N at "Placement".
Fig. 37 SIPLACE Pro "component shape editor" - "basic handling" tab
Assembly Instructions 01005-Packet
Edition 12/2007
62
3.7.2.2 Controlling and Configuring Advanced Settings, where necessary
Æ Select the "Advanced Edits" tab.
Æ Go to "Check component process" and select the list field
"No vaccum". Then activate the checkbox "Pickup".
Æ Go to "Pickup Mode" and select the list field "No Contact".
Æ Enter 1.0 N at "Pickup Force".
Æ Check the standard settings for the travel profiles (travel profiles 33 or 34 for verified placement
and 35 for verified pickup) and make corrections, if necessary.
Fig. 38 SIPLACE Pro "component shape editor" - "advanced edits" tab
Æ Go to the "Air Kiss" option to check the settings for air kiss. Make edits only when necessary
in accordance with the following values:
Air kiss values for placement (only C&P head)
0 mbar: no air kiss
1- 50 mbar: short air kiss (approx. 4ms)
51-150 mbar: medium air kiss (approx. 12ms)
> 150 mbar: long air kiss (approx. 37ms)
Assembly Instructions 01005-Packet
Edition 12/2007
63
Æ Go to "Waiting time during pickup" and enter the value 10 ms (only for C&P 12 head).
NOTE:
If SIPLACE D1/D2/D4 is used together with the SIPLACE X-series, you need to create and main-
tain a second component shape for 01005 in conjunction with the C&P 20 head, where necessary.
In case the 01005-component is placed with the C&P 20 head, the "Waiting time during pickup"
option must be adjusted to the value 0 ms! 3
3.7.2.3 Assigning Nozzles
Æ Select the "Nozzles" tab.
Æ Select from the list of the available nozzles the "905" type and use the "Add >" button to add
this entry to the list auf the selected nozzles.
Fig. 39 SIPLACE Pro "component shape editor" - "nozzles" tab