DEK高级培训资料.pdf - 第164页

Vision Height • Set in diagnostics • Saved to configuration file (config.cfg) • Issue 2: July 2007 • Rising table position to allow camera to capture board fiducials... Home position V isio n height

100%1 / 240
Calibrations Summary
Calibrations required if Config.cfg was
deleted or corrupt:
Vision Height
Print Height
Board stop X Offset
Issue 2: July 2007
Board stop X Offset
Camera Reference Position
Vision Scale Calibration
Vision Offset Calibration
Squeegee Reference Heights
plus other settings such as cleaner type etc
Vision Height
Set in diagnostics
Saved to configuration
file (config.cfg)
Issue 2: July 2007
Rising table position to
allow camera to
capture board
fiducials...
Home position
Vision height
Reference print height
Set in diagnostics
Saved to configuration
file (config.cfg)
Rising table position to
Print Height
Issue 2: July 2007
Reference print height
Home position
Rising table position to
place board in contact
with stencil for printing.
Note: Set without board,
then when printing,
board thickness is
taken into account….