A10011-ASM-T47-EN-Spec-X-Serie S_DMS.pdf - 第51页

51 Technical data Compressed air supply Compressed air supply Compressed air pressure values p min p max 0.5 MPa = 5.0 bar 1.0 MPa = 1 0 bar Operating pressure 0.48 MPa ± 0.025 MPa (4.8 bar ± 0.25 bar) Compressed air con…

100%1 / 72
50
Technical data
Electrical ratings and energy consumption
SIPLACE X2 S
Electrical ratings
Supply voltage Fuse
Main power supply 3 x 380 V~ to 3 x 415 V~ ± 10 %; 50/60 Hz
3 x 200 V~ to 3 x 240 V~ ± 10 %; 50/60 Hz
a
a) With options package
Mains power con-
nection
Cable 5 x 4 mm² with CEKON connector (3 x 380 V~ to 3 x 415 V~)
Cable 5 x 4 mm² (3 x 200 V~ to 3 x 240 V)
Energy consumption
With a vacuum pump
b
b) Vacuum pump for C&P20 head only.
With two vacuum pumps
b
Without vacuum pumps
c
c) Optional
Nominal apparent
power
2.5 kVA -- 1.3 kVA
Nominal active
power
1.7 kW -- 1.0 kW
SIPLACE X3 S / X 4 S / X4i S
Electrical ratings
Supply voltage Fuse
Main power supply 3 x 380 V~ to 3 x 415V~ ± 10 %; 50/60 Hz
3 x 200 V~ to 3 x 240 V~ ± 10 %; 50/60 Hz
a
Mains power con-
nection
Cable 5 x 4 mm² with CEKON connector (3 x 380 V~ to 3 x 415V~)
Cable 5 x 4 mm² (3 x 200 V~ to 3 x 240 V)
Energy consumption
With one vacuum pump
b
With two vacuum pumps
b
Without vacuum pumps
c
Nominal apparent
power
2.5 kVA 3.85 kVA 1.3 kVA
Nominal active
power
1.7 kW 2.45 kW 1.0 kW
51
Technical data
Compressed air supply
Compressed air supply
Compressed air pressure
values
p
min
p
max
0.5 MPa = 5.0 bar
1.0 MPa = 10 bar
Operating pressure 0.48 MPa ± 0.025 MPa (4.8 bar ± 0.25 bar)
Compressed air connec-
tion
R 3/4" inner thread (pipe thread) with 1/2" hose connection
Compressed air consumption
a
a) Average consumption values.
Placement head configuration Compressed air
consumption
b
with vacuum pump
b) Under normal atmospheric conditions at 20°C and 1013 hPa.
Compressed air
consumption
without vacuum
pump
c
c) Optional
SIPLACE X4i S/X4 S
C&P20 P/C&P20 P/C&P20 P/C&P20 P
C&P20 P/C&P20 P/CPP/CPP
C&P20 P/C&P20 P/TH/TH
C&P20 P/C&P20 P/CPP_H
d
/TH
CPP/CPP/CPP/CPP
CPP/CPP/CPP_H/TH
CPP/CPP/TH/TH
CPP/TH/TH/TH
TH/TH/TH/TH
d) CPP_H = Multistar CPP in high assembly position
260 Nl/min
370 Nl/min
330 Nl/min
350 Nl/min
480 Nl/min
460 Nl/min
440 Nl/min
420 Nl/min
400 Nl/min
990 Nl/min
720 Nl/min
680 Nl/min
700 Nl/min
480 Nl/min
460 Nl/min
440 Nl/min
420 Nl/min
400 Nl/min
SIPLACE X3 S C&P20 P/C&P20 P/C&P20 P
C&P20 P/C&P20 P/CPP
C&P20 P/C&P20 P/TH
CPP/CPP/CPP
CPP / TH
CPP/TH/TH
TH/TH/TH
185 Nl/min
230 Nl/min
230 Nl/min
360 Nl/min
340 Nl/min
340 Nl/min
300 Nl/min
720 Nl/min
600 Nl/min
590 Nl/min
360 Nl/min
340 Nl/min
340 Nl/min
300 Nl/min
SIPLACE X2 S C&P20 P / C&P20 P
C&P20 P/CPP
C&P20 P/TH
CPP / CPP
CPP / TH
TH / TH
130 Nl/min
185 Nl/min
165 Nl/min
240 Nl/min
220 Nl/min
200 Nl/min
480 Nl/min
360 Nl/min
340 Nl/min
240 Nl/min
220 Nl/min
200 Nl/min
Compressed air specification
Particle size 0.1 µm
Particle density 0.1 mg/m³
Maximum oil content
(class 1)
Particle density 0.01 mg/m³
Pressure dewpoint
(class 4)
Dewpoint + 3°
52
Technical data
Electrical connection and compressed air supply
1 = Electrical connection
2 = Compressed air connection
The connections are run into the machine from below and then connected to the power supply
or pneumatic unit.