CM602规格说明书(英文).pdf - 第53页

CM602-L 2006.0515 - 48 - C-8 To prepar e feeders externa lly. Customer Feeder cart Cart stand box (Ele ctric sou rce box) (NM-EJW 1A) ・ Four feeder cart s are in cluded w ith the standar d configura tion mac hine. If req…

100%1 / 74
CM602-L 2006.0515
- 47 -
C-6
To select the stick feeder according to the production pattern.
Customer
Intelligent stick feeder
Customer
Guide block
For information about the types of intelligent stick feeder, see “4.4 Feeder Carriage Configuration”.
The intelligent stick feeder is compatible with CM402, CM401, CM400, DT401, and CM212.
Guide block is used when components are difficult to be picked up by the placement machine in the feeding method with
the tip-cut sticks because the transfer state of components and the components posture at the pick-up position are not
good depending on the component/stick shape, etc.
C-7
To select the bulk feeder according to the production pattern.
Customer
Intelligent bulk feeder
Factory
By table
Air supply unit for the feeder
For information about the types of intelligent bulk feeder, see “4.4 Feeder Carriage Configuration”.
The intelligent bulk feeder is compatible with CM402, CM401, CM400, DT401, and CM212.
To use the intelligent bulk feeder, the air supply unit for the feeder needs to be installed on the machine’s side.
Even when the air supply unit for the feeder is installed, the single tape feeders can be set as usual.
CM602-L 2006.0515
- 48 -
C-8
To prepare feeders externally.
Customer
Feeder cart
Cart stand box
(Electric source box)
(NM-EJW1A)
Four feeder carts are included with the standard configuration machine.
If requiring more feeder carts for external preparation, please purchase as many ones as you need.
The cart stand box is necessary for external preparation.
This unit supplies electric source to feeders during preparation.
To use the parts verify function, the cart stand box needs to support Pana PRO/CVT optionally.
Electric source specifications of the cart stand box
Rated voltage Single-phase, AC 100 V to AC 240 V
Frequency 50 Hz/60 Hz
Power consumption 320 VA
The feeder cart and the cart stand box are compatible with CM402, CM401, CM400, DT401, and CM212.
The floor slope in the feeder cart installation area needs to be 6 mm or less in the right/left direction and 11 mm or less in
the forward/backward direction. If the floor slope is beyond the above limit, the feeder cart cannot be taken in and out.
C-9
To manage and store tape feeders.
Customer
Tape feeder stand
This is the stand for tape feeders. Please use this for managing and storing feeders.
Please decide the number of stands, based on the number of stocks and the usage.
For the 8 mm double tape feeder, for example, up to 90 ones can be stocked.
The tape feeder stand is compatible with CM402, CM401, CM400, DT401, and CM212.
CM602-L 2006.0515
- 49 -
C-10
To place tray feeding components.
On-site
Shuttle tray feeder ST40S-20
(2 tray magazines and 20 tray pallets included)
The shuttle tray feeder ST40S-20 can be one or tow installed on the rear side of CM602-L main body.
It cannot be installed on the front side.
The power will be supplied from CM602-L.
The rated capacity of CM602-L allows the shuttle tray feeders to be connected.
To install the shuttle tray feeder, “Extension conveyor for shuttle tray feeder” (recommended) needs to be selected.
Factory
Shuttle tray feeder installation ready
To support the shuttle tray feeder, the following cables need to be incorporated inside CM602-L in order for the con-
trolled coupling between CM602-L and the shuttle tray feeder:
c Power cable: one type (for side A / for side B)
d Signal cable: two types (for side A / for side B)
On-site
Direct tray feeder DT50S-20
(2 tray magazines and 21 tray pallets included)
DT50S-20 holds a maximum of 20 types of trays.
One / One or two tray feeders can be connected for type D-0, D-1, E-0 / F-0 respectively.
“Direct tray feeder installation ready” and “6-row feeder base mount” need to be selected.
Factory
Direct tray feeder installation ready
To support the direct tray feeder, the following cables need to be incorporated inside CM602-L in order for the controlled
coupling between CM602-L and the direct tray feeder:
c Power cable: one type (for side A / for side B)
d Signal cable: two types (for side A / for side B)
Factory
6-row feeder base mount