CM602规格说明书(英文).pdf - 第58页
CM602-L 2006.0515 - 53 - D-1 To plac e BGA, C SP. On-site By table Si de ligh tin g ・ The light ing intende d for the bump reco gnition is neces sary for pla cement BG A and CSP. ・ The stage w here the mul ti-fun ctional…

CM602-L 2006.0515
- 52 -
4. Attachments
Item
Quantity
Master jig
1 pc.
Aluminum case
1 pc. (For storage and carriage of master jig)
Resin case
1 pc.
Jig tape set
8 mm: 3 pcs., 12 mm: 1 pc., 16 mm: 1 pc.,
24 mm: 1 pc., 32 mm: 1 pc.
RS-232C cable
1 pc.
Wrench 2 pcs.
Illumination lamp
For illumination of camera section (for re-
placement): 1 pc.
Power cable
∗
1
(for place of des-
tination)
One type should be selected from among six
types according to the place of destination.
Communication
check connector
1 pc. (For checking the communication with PC)
Maintenance
software
CD-ROM: 1 pc.
Instruction manuals: 1 set
Documentation
Parts list: 1 set
5. Hardware/OS Requirements
∗
2
A PC should be prepared by the customer.
The specifications are as follows.
Item
Requirements
Main body
IBM PC/AT-compatible machine
CPU
32-bit CPU such as Pentium III 800 MHz or
faster, or Celeron 800 MHz or faster
Motherboard
Fully compatible with IBM
Serial/Parallel I/O
Fully compatible with IBM. RS-232C port is required.
Graphics board
XGA or higher (24-bit color or higher)
Desktop area: 1 024 × 768 dots or more
(1 240 × 1 024 dots or more recommended)
16 MB or more of VRAM
(Recommended: Independent of the system memory)
System memory
256 MB or more
(512 MB or more recommended)
HDD
4 GB or more of available software-installed
drive space
CD-ROM unit
8x or faster (CD-RW also available)
Keyboard
English version: 101 keyboard
Mouse
PS/2 or USB connection
Monitor
XGA or higher supported
(Recommended: SXGA or higher supported)
External bus
OHCI-compliant IEEE1394 interface adapter required
OS
Windows XP (Professional, English version),
Direct X 8.0 or later
* The OS installed is limited to the English version
only. (Not installed with Windows XP (Professional,
Japanese version) etc.)
6. Power and Air Sources
7. Dimensional Drawing
(Unit : mm)
∗
1
Selection of the accompanying power cable for control BOX:
Since the type and shape of outlet vary with the region, please choose one type of power cable according to your region.
Major regions applicable
Plug type
Plug shape Outlet shape
Compatible specification
Model number
Japan
A
Electrical Appliance and
Material Safety Law
N610006918AA
North America, Canada, Mexico
A
UL
、
CSA
N610006919AA
Europe (except for England), Ko-
rea, Indonesia, Italy, Austria, Spain,
Germany, Turkey, Hungary, France
S
CE N610006921AA
England, Hong Kong, Singapore,
Malaysia
BF
BS N610006922AA
China, the Philippines
O
CCC N610006920AA
Australia
O
AS N610006923AA
Regulator
Valve
To be connected with
φ
4 air tube when
necessary.
To be required only for the operation
check of the bulk feeder and the 32 mm
paper adhesive feeder.
Power supply switch
1 155
745
400
500

CM602-L 2006.0515
- 53 -
D-1
To place BGA, CSP.
On-site
By table
Side lighting
・
The lighting intended for the bump recognition is necessary for placement BGA and CSP.
・
The stage where the multi-functional head is selected at the time of purchase of the machine comes standard with the
side lighting. The stage where the high-speed head is selected at the time of purchase of the machine comes optional
with the side lighting. Whether the high-speed head or the multi-functional head, a spare head does not come with the
side lighting; therefore, please select this option when needed.
D-2
To detect the floating leads of SOP, QFP, etc.
On-site
By table
Lead checker
・
Floating leads are detected by laser scanning all the leads of SOP, QFP, etc. whose size is 50 mm × 50 mm or under.
・
Please select this for each table on the stage for which the Multi-functional heads are selected.
(It cannot be installed on the High Speed head stage.)
D-3
To align and eject the NG components onto the conveyor.
Customer
By table
NG-components ejection conveyor
・
This is used for ejecting recognition NG components.
・
Please select this for each table on the stage for which the Multi-functional head is selected.
(It cannot be installed on the High Speed head stage.)
・
This option will occupy two feeder setting slots.
・
The NG-components ejection conveyor is compatible with CM402, CM401, CM400, and DT401.
Not sharable with CM212.

CM602-L 2006.0515
- 54 -
D-4
To replace with High Speed head (8 nozzles) or High Speed head (12 nozzles).
On-site
By stage
High Speed head (12 nozzles)
・
Please select this option if replacing the High Speed head (8 nozzles) or the Multi-functional head with the High Speed
head (12 nozzles).
・
This can be replaced for each stage (two heads). It is not possible to set the different heads onto the front and the rear
table.
・
For High Speed head (12 nozzles) type, the versions of the software incorporated in the double tape feeder and the
feeder cart need to be updated to Ver. 5.00 or later and Ver. 1.20 or later, respectively.
(Because of the gang feed support in right and left lanes of double tape feeder.)
・
Attachments: “Gang feed support” labels (the identification labels for the software-updated feeder and feeder cart)
On-site
By stage
High Speed head (8 nozzles)
・
Please select this option if replacing the High Speed head (12 nozzles) or the Multi-functional head with the High Speed
head (8 nozzles).
・
This can be replaced for each stage (two heads). It is not possible to set the different heads onto the front and the rear
table.
・
For the high-speed head type, the nozzle changer is optional. B-3 “Nozzle changer (for High Speed head)” is required
separately.
D-5
To replace with Multi-functional head.
On-site
By stage
Multi-functional head
Nozzle changer
(for Multi-functional head)
(This holds 15 large nozzles.)
・
Please select this option if replacing the high-speed head with the multi-functional head.
When needed, please select the optional side lighting (D-1 Side lighting) because it is not included as standard.
・
This can be replaced for each stage (two heads). It is not possible to set the different heads onto the front and the rear
table.
・
Nozzle changer (for the Multi-functional head) is included with the Multi-functional head.